E2610-LEL

Rev 10.05.2021

Product description

E2610 series gas detectors are compact and easy-to-use instruments. The devices utilize
novel fully calibrated and temperature compensated gas sensors with excellent
repeatability, stability, and long lifetime.

Two relays with switch-over contact may be used for remote signaling or ventilation
control. Flashing LED and an internal buzzer give alarms at two setpoints.

Safety requirements

Misuse will impair the protection of the product. Always adhere to the safety provisions
applicable in the country of use.

Do not perform any maintenance operation with the power on. Do not let water or foreign
objects inside the device.

Removal of the PCB from the enclosure voids the warranty. Do not touch the electronic
components directly, as they are sensitive to static electricity.

Connection diagrams can be found in the connections section. The device might not
perform correctly or be damaged if the wrong power supply is connected.

External circuits connected to the equipment should have sufficient insulation rating
according to the environmental conditions and equipment power.

A disconnecting device that is marked as such and easily accessible should be included in
the installation of this product.

Operating conditions

The device should be used both in a non-hazardous indoor area and in a basic
electromagnetic environment, where the latter is defined in EN 61326-1. Avoid strong
mechanical shock and vibrations. Avoid corrosive atmosphere and areas highly
contaminated with dust, oil mist, etc. Keep the instrument away from direct sunlight. A
sudden temperature or humidity change might affect the sensitivity of the sensor.

9

Summary of Contents for E2610-LEL

Page 1: ...Combustible Gas Detector E2610 LEL User Manual...

Page 2: ...thane 6 Propane 7 Specifications 8 Product description 9 Safety requirements 9 Operating conditions 9 Installation guidelines 10 Connections 11 Operation 13 Maintenance 13 Calibration 13 Delivery set...

Page 3: ...Ethyne Chemical formula HC CH Molar weight 26 Relative gas density to air 0 90 Conversion 1 ppm 1 06 mg m3 Boiling point 84 C Low explosive limit LEL vol in air 2 3 2 5 Upper explosive limit UEL vol...

Page 4: ...are referred to as LPG liquefied petroleum gas Chemical formula n butane CH3CH2CH2CH3 iso butane CH3CH CH3 CH3 Molar weight 58 Relative gas density to air 2 0 Conversion 1 ppm 2 38 mg m3 Boiling poin...

Page 5: ...e electrolysis of aqueous solutions In industrial production the main source of hydrogen is hydrocarbons Chemical formula H2 Molar weight 2 Relative gas density to air 0 07 Conversion 1 ppm 0 0818 mg...

Page 6: ...Synonyms Marsh Gas Natural Gas Carbon tetrahydride Hydrogen carbide Chemical formula CH4 Molar weight 16 Relative gas density to air 0 55 Conversion 1 ppm 0 65 mg m3 Boiling point 161 49 C Low explosi...

Page 7: ...r weight 44 Relative gas density to air 1 55 Conversion 1 ppm 1 80 mg m3 Boiling point 42 C Low explosive limit LEL vol in air 1 7 2 1 Upper explosive limit UEL vol in air 9 5 Odor Odorless when pure...

Page 8: ...gnaling Buzzer 2 kHz 85 dB red LED LEDs Green red operation fault red gas alarm Enclosure ABS plastic with ventilation slots wall mount protection class IP20 Dimensions H85 W85 D37 mm CE marking Accor...

Page 9: ...uch the electronic components directly as they are sensitive to static electricity Connection diagrams can be found in the connections section The device might not perform correctly or be damaged if t...

Page 10: ...he device should be accessible for maintenance and repair The aforementioned conditions above will affect the coverage area of the device however the coverage area for a detector is usually between 2...

Page 11: ...the enclosure by gently pulling along four guiding pins 2 Attach the base to the wall with two screws see drawings below 3 Use rounded cutouts on the side of the base to let in the cables from the po...

Page 12: ...mon terminal RE2 NC Relay 2 normally closed terminal L 90 265 VAC Phase optional 24 VAC VDC N 90 265 VAC Neutral optional 24 VAC VDC The terminals on the E2610 series devices are suitable for a wide r...

Page 13: ...w 70 of the LOW alarm setpoint If the gas level exceeds the HIGH alarm setpoint the bottom red LED starts flashing and the buzzer starts beeping at a rate of 2 Hz and also the relay RE2 switches over...

Page 14: ...as Detector E2610 CO Mounting accessories 2 screws and 2 plastic dowel plugs Order code for E2610 LEL options E2610 options Order code Integrated 90 265 V mains power supply module E2610 LEL 230 Integ...

Page 15: ...Manufacturer will at its option either repair or replace a product that proves to be defective This warranty is void if the product has been operated in conditions outside ranges specified by the Manu...

Reviews: