![Everwell MRTH User And Installation Manual Download Page 8](http://html1.mh-extra.com/html/everwell/mrth/mrth_user-and-installation-manual_2445313008.webp)
EMERGENCY FUNCTION & AUTO-REST
ART FUNCTION
6
Remark: the external static pressure of heat pumps is 0 Pa for all models.
The shape and position of the emergency button
may be different according to the model, but their
function is the same.
ON/OFF
Emergency
button
The emergency button in some models could be on
the right part of the unit under the front panel.
The appliance is preset auto - restart function by
manufacturer. In case of a sudden power failure, the
module memorizes the setting conditions before the
power failure.
when the power restores, the unit
restarts automatically with all the previous settings
preserved by the memory function.
Open and lift the front panel up to an angleto reach the
emergency button.
1. One press of the emergency button(one beep) will
lead to the forced COOLING operation
2. Two press of the emergency button within 3 sec
(two beeps) will lead to the forced HEATING
operation.
3. To switch off the unit , you just need to press the
button again ( a single long beep) .
4. After 30 minutes in forced operation , the air
conditioner will automatically start working in 23
cooling mode, auto fan speed.
* The FEEL function is described in page 15.
If the remote controller fails to work or maintenance
necessary,
proceed as follows:
display PCB
front panel
To deactivate the AUTO-RESTAR T function ,pro-
ceed as follows:
1. Switch the air conditioner off and plug it off.
2. Press the emergency button meanwhile plug
it in.
3. Keep pressing the emergency button for more
than 10 seconds until you hear four short beeps
from the unit. The AUTO-REST ART function is
deactivate.
To activate the AUTO - RESTAR T function ,
follow the same procedure until you hear three
short beeps from the unit.
Emergency
button
ON / OFF
POWER SLEEP
TIMER RUN
EMERGENCY FUNCTION
AUTO-RESTAR
T FUNCTION
Emergency
button
ON/OFF
front panel
1033A