1. Prepare the Heating Film according to the process outlined in the
General Installation Instructions beginning on page #24.
2. Adhere the Heating Film to the slab or sub-floor using a moisture
resistant or water proofing indoor/outdoor flooring adhesive by rolling
back 1/2 a sheet at a time, using a 3/16”-1/4”(5-6mm) V-notch trowel
to apply adhesive to the floor, setting the Heating Film down onto the
adhesive. Using a roller, apply a continuous, even pressure with
overlapping strokes making a permanent bond between the sub-floor
and film.
3. Install the linoleum or vinyl flooring according to the manufacturer’s
specifications.
LINOLEUM AND VINYL INSTALLATION
SLAB
GLUE/ADHESIVE
FLOORING
THERMAL BARRIER (OPTIONAL)
HEATING FILM
JOIST 16” O.C. TYP.
PLYWOOD SUBFLOOR
GLUE/ADHESIVE
OR
NOTE: CHECK WITH THE FLOORING MANUFACTURER FOR MAXIMUM
TEMPERATURE RATINGS THAT ARE APPROPRIATE FOR YOUR FLOORING AND
SET THE THERMOSTAT ACCORDINGLY.