MViP User's Guide
Revision 1.1
Page - 3
5. Connect the power leads (using approved IEC standards) to both of the power supplies on the back of
the MViP. Please note: In order to be redundant power supplies, both power supplies must be
connected to a power lead. If only one power lead is used, the MViP will sound an alarm (high pitched
buzzer) when the unit is turned on in order to alert the user of a failed power supply. Please refer to
section 2.1.1 for further information.
6. Connect the Ethernet cables to the network ports on the back of the MViP. Please note: To avoid an IP
conflict on the networks, it is best to configure the network settings before physically connecting the
cables into the network ports.
The upper network connection is used for management purposes (SNMP, etc.). The lower network
connection is used for data. Both ports should be connected to Ethernet network switches. Properly
managed switches/routers should be used when connecting the MViP to the data network. For details
on network topology support please see section 3 of the manual.
7. Connect a USB or PS2 keyboard and mouse to the USB and PS2 ports on the rear of the unit.