EQT Router User Manual
Revision 1.9.1
Page 41
5.5.
CLEAN SWITCH OUTPUT CONTROL PARAMETERS (–CS VERSIONS ONLY)
The following shows the
Clean Switch Output Control
tab for the EQT. Table 9 provides further details
about each control.
Figure 5-4: Clean Switch Output Control Tab
Note: ACO2 slot 1 is responsible for outputs 1 and 2 clean switch. ACO2 slot 2 is
responsible for outputs 13 and 14 clean switch (EQT-3204 Only)
Note: The companion IP address must be set in order to control the clean/quiet
switch functions in VistaLINK PRO. Details are in section 4.2.10
Parameter
Description
Output Status
Enables or disables the clean and quiet path on outputs 1, 2, 13 and 14.
Relay Status
Enables or disables the relay to bypass outputs 1, 2, 13 and 14.
Companion IP Addresses
Displays the Companion Address.
Table 9: Clean Switch Output Control Parameters