- 14 of 15 -
Contents Subject to Change
av.evertz.com
Rev 03
3.
Click the Browse button and select the desired software update .bin file.
4.
Click the Upload button to begin the software update process. All the LEDs on the unit will
become brightly lit indicating the unit is upgrading. When the software update process has
finished, a popup will be displayed on the Web UI stating the upgrade was successful, all LEDs on
the unit will turn off, and the unit will automatically reboot. When the unit has finished rebooting,
all the USB port LEDs will blink fast indicating that the USB ports need to be upgraded.
5.
Power off the unit.
6.
Copy the USB update .img file to the root of each of your USB drives.
Note: Each USB port on the unit needs to be updated, but can be updated simultaneously using
a separate USB drive for each port. For example, if you want to update all five USB ports on
an ATOM-USB-5 at once, you will need five USB drives. You can update each USB port one
at a time, but it will take much longer updating each USB port individually.
7.
Insert each USB drive containing the USB update .img file into the respective USB ports on the
ATOM-USB and then power on the unit. The red (Rec/Stop) and green (Mount/Eject) LEDs for the
respective USB ports that have been chosen to be upgraded will flash in tandem from dim to
bright with a 500ms cadence. When the update process has finished for a USB port, the red
(Rec/Stop) and green (Mount/Eject) LEDs for the respective USB port will turn off.
Note: Updating a USB port is dependent on the read speed of the USB drive you are using and
can take up to 10 minutes.
8.
When all the LEDs for all the respective USB ports that have been chosen to be upgraded turn off,
power off the unit.
9.
Power on the unit to reboot the device. Your ATOM-USB should now be fully upgraded.
Note: After rebooting your unit, if a USB port’s red (Rec/Stop) and green (Mount/Eject) LEDs blink
quickly, the USB port will not be functional. Fast blinking indicates a firmware error. A
message will also be displayed on the Web UI indicating which USB port possesses a
firmware error. In such instances, repeat Steps 5 to 9 above for the affected USB port(s).
Factory Defaulting Your Device
To reset the unit to its factory default settings, hold down the first USB port’s red (Rec/Stop) and green
(Mount/Eject) buttons simultaneously for 10 seconds until all the LEDs turn bright. When all the LEDs turn
bright, release the buttons and the factory default process will start, which is indicated by the LEDs turning
off for up to 20 seconds, followed by the unit rebooting. Once the device has finished the boot up process,
the device will have reverted its IP address back to 192.168.1.168 along with this factory default settings.