7800R4X4-RF Switch Series
4X4 RF Router, Software Expandable to 8x16
Revision 1.0
Page 15
4.4.
NOTIFY
Figure
4-10 : WebEASY
®
- Notify Section
The Notify tab contains all the alarm status present or not present identified by Red or Green indicators.
4.4.1. Input Fault Present
Input Power High:
This indicator shows red if the input power is beyond threshold limit.
Input Power Low:
This indicator shows red if the input power is below threshold limit.
Input Squelch:
This indicator shows red if squelch is enabled.
AGC out of range:
This indicator shows red if AGC power is beyond the limit.
LNB short:
This indicator shows red if there is short on the LNB input.
LNB Current high:
A range of values indicating the maximum LNB current.
LNB Current low:
A range of values indicating the minimum LNB current.
4.4.2. Output Fault Present
Output Routing:
This field indicates red if routing fails for some reason.