7700 MultiFrame Manual 

7707VB-8-ASI-OC3  8 Channel ASI + Ethernet SONET / SDH  Fiber Transceiver 

Page - 6

 Revision 

1.0 

3. SPECIFICATIONS 

3.1. 

SERIAL VIDEO INPUT 

Standards: 

DVB-ASI 

Number of Inputs: 

 

8 independent DVB-ASI signals with combined bandwidth of 135Mb/s 

Connector:

  

 

BNC per IEC 61169-8 Annex A 

Equalization:

  

 

Automatic 250m with Belden 1694 or equivalent cable 

Return Loss:

 

 

> 15 dB up to 270Mb/s 

Frequency Offset Tolerance: 

±50ppm 

 

3.2. 

SERIAL VIDEO OUTPUTS 

Standards: 

DVB-ASI 

Number of Outputs: 

8 independent DVB-ASI signals with combined bandwidth of 135Mb/s 

Connectors:

  

BNC per IEC 61169-8 Annex A 

Signal Level:

 800mV(nominal) 

DC Offset:

 0V 

±

  0.5V 

Rise and Fall Time:

 900ps(nominal) 

Overshoot:

  

< 10% of amplitude 

Return Loss:

 > 

12dB 

Wide Band Jitter: 

 

< 0.2UI 

 

3.3. OPTICAL 

OUTPUT 

Standards:  

OC-3/STM-1

 

Number of Outputs: 

1

 

Connector:

 

Female SC/PC, ST/PC or FC/PC 

Return Loss: 

> 14 dB 

Wide Band Jitter:

 < 

0.2UI 

Fiber Size:

 9 

µ

m core / 125 

µ

m overall 

Wavelengths: 

Standard: 

1310nm, 1550nm (nominal) 

CWDM: 

1270nm to 1610nm (See ordering information) 

DWDM: 

C-Band channel 20 to 60, 100GHz spacing (ITU-T G.694.1 compliant) 

Output Power:

 

 

1310nm FP: 

 

 

-7dBm 

±

 1dBm 

1550nm & CWDM: 

 

0 dBm 

±

 1dBm 

DWDM:  

+7dBm 

±

 1dBm 

 

Summary of Contents for 7707VB-8-ASI-OC3

Page 1: ... the Errored Seconds Ratio 14 4 2 1 6 Displaying the Loss of Signal seconds in Line Layer 14 4 2 1 7 Displaying the Link Output Reference Clock Source 14 4 2 1 8 Displaying the Link Input Status 15 4 2 1 9 Displaying Input ASI Status Information 15 4 2 1 10 Displaying the Total Input ASI Bandwidth Used 15 4 2 1 11 Displaying Output ASI Status Information 16 4 2 1 12 Displaying the Output ASI Bandw...

Page 2: ... VISTALINK CONTROLLED PARAMETERS 27 6 4 VISTALINK TRAPS 28 Figures Figure 1 1 7707VB 8 ASI OC3 Block Diagram 2 Figure 2 1 7707VB 8 ASI OC3 Rear Panel 3 Figure 2 2 Reproduction of Laser Certification and Identification Label 4 Figure 4 1 Location of Status Indicators and Controls 8 Figure 4 2 Card Edge Menu 10 Figure 4 3 STAT Menu Structure 11 Figure 4 4 Control Menu 18 Figure 5 1 Location of Statu...

Page 3: ...d or implied The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed in relation to any errors or omissions unless speci...

Page 4: ...rame Manual 7707VB 8 ASI OC3 8 Channel ASI Ethernet SONET SDH Fiber Transceiver Revision 1 0 WARNING Never look directly into an optical fiber Non reversible damage to the eye can occur in a matter of milliseconds ...

Page 5: ...OC3 1550 nm DFB 0dBm output suitable for distances up to 75 km There are several versions with built in isolators specifically suited to coarse wave division multiplexing CWDM applications These versions all have 0dBm output and are suitable for distances up to 75 km 7707VB27 8 ASI OC3 1270 nm DFB 7707VB29 8 ASI OC3 1290 nm DFB 7707VB31 8 ASI OC3 1310 nm DFB 7707VB33 8 ASI OC3 1330 nm DFB 7707VB35...

Page 6: ...INK Frame Controller module in slot 1 of the frame using the 9000NCP Network Control Panel or Evertz VistaLINK PRO or other third party SNMP manager software Automatic coaxial equalization up to 250m Belden 1694A or equivalent cable Fully hot swappable from front of frame with no fiber coax disconnect reconnect required Supports single mode and multi mode fiber optic cable Optical output wavelengt...

Page 7: ...with DVB ASI for a combined bandwidth of 135Mb s These inputs provide adaptive compensation for up to 250m of industry standard Belden 1694A cable ASI OUT 1 8 Eight independent BNC output connectors compatible with DVB ASI for a combined bandwidth of 135Mb s OPTICAL INPUT SC PC SC PC with cover shown ST PC or FC PC female connector This wide range input accepts optical wavelengths of 1270nm to 161...

Page 8: ... enough room on the product to place the label it is reproduced here in the manuals There is no date of manufacture on this label as it can be traced by the bar code label placed on the printed circuit board of each Evertz plug in module The Model number is one of 7707VB13 8 ASI OC3 7707VB15 8 ASI OC3 7707VBxx 8 ASI OC3 xx 27 29 31 33 35 37 43 45 47 49 51 53 55 57 59 61 7707VBDyyy 8 ASI OC3 Dyyy r...

Page 9: ...f the optical core and therefore care must be taken to prevent fiber damage due to heavy objects or abrupt fiber bending Evertz recommends that you maintain a minimum bending radius of 5 cm to avoid fiber bending loss that will decrease the maximum attainable distance of the fiber cable The Evertz fiber optic modules come with cable lockout devices to prevent the user from damaging the fiber by in...

Page 10: ...ber of Outputs 8 independent DVB ASI signals with combined bandwidth of 135Mb s Connectors BNC per IEC 61169 8 Annex A Signal Level 800mV nominal DC Offset 0V 0 5V Rise and Fall Time 900ps nominal Overshoot 10 of amplitude Return Loss 12dB Wide Band Jitter 0 2UI 3 3 OPTICAL OUTPUT Standards OC 3 STM 1 Number of Outputs 1 Connector Female SC PC ST PC or FC PC Return Loss 14 dB Wide Band Jitter 0 2U...

Page 11: ...rd 28dBm 3 5 ELECTRICAL Voltage 12VDC Power 23 Watts Non DWDM 25 Watts DWDM 3 6 PHYSICAL Number of Slots 3 3 7 COMPLIANCE Electrical Safety CSA Listed to CSA C22 2 No 60065 03 UL 60065 03 IEC 60065 2001 12 7th Edition Complies with CE Low voltage directive 93 68 EEC Laser Safety Complies with 24 CFR 1040 10 and 1040 11 except for deviations pursuant to LN No 50 dated July 26 2001 Complies with IEC...

Page 12: ...ach of the two 7707VB 8 ASI OC3 boards has a red and a green local fault LED The red LED on either board will be ON if a local board fault exits such as a blown fuse On the board that also has the pushbutton and display a red LED also indicates that a laser fault exists or that the laser is set to Discontinuous mode with no valid inputs present The LOCAL FAULT indications can also be reported to t...

Page 13: ...monitor mode STAT or control mode CTRL Figure 4 2 shows the menu structure for the 7707VB 8 ASI OC3 card Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 OK LASR ERR LINK ERR STD OC SDH PWR 40 to 0 dBm TIME 0 to 899 15m ESL SESL ESS SESS ESP SESP SEFS 0 to 9999 TIME 0 to 1439 CIC 24h ESL SESL ESS SESS ESP SESP SEFS 0 to 9999 LIC 15m 24h ESL SESL ESS SESS ESP SESP SEFS 0 to 9999 ESR SECT LINE PATH 0...

Page 14: ... DIS EN IN1 MAXB 1 107 OUTP DIS EN IN2 MAXB 1 107 OUTP DIS EN IN3 MAXB 1 107 OUTP DIS EN IN4 MAXB 1 107 OUTP DIS EN IN5 MAXB 1 107 OUTP DIS EN IN6 MAXB 1 107 OUTP DIS EN IN7 MAXB 1 107 OUTP DIS EN IN8 MAXB 1 107 These values may only be modified if the correct passcode is enetered OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUTP BACK DIS EN IASI ASI1 ASI2 ASI3 ASI4 ASI5 ASI6 ASI7 ASI8 BACK RST ERST OA...

Page 15: ...formation about setting up the module in control mode CTRL see section 4 2 2 Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 OK LASR ERR LINK ERR STD OC SDH PWR 40 to 0 dBm TIME 0 to 899 15m ESL SESL ESS SESS ESP SESP SEFS 0 to 9999 TIME 0 to 1439 CIC 24h ESL SESL ESS SESS ESP SESP SEFS 0 to 9999 LIC 15m 24h ESL SESL ESS SESS ESP SESP SEFS 0 to 9999 ESR SECT LINE PATH 0 0 100 LOSL 0 to 9999 OUT RE...

Page 16: ... FIBR menu item and then choose the PWR menu item STAT FIBR PWR 40 to 0 dBm LOW OVER The following indications are possible 40 to 0 Optical Power input dBm within monitoring range LOW Optical Power input below 40dBm OVER Optical Power input above 0dBm 4 2 1 3 Displaying the Current Interval Counter This menu displays Current Interval Performance Counters useful for monitoring network integrity To ...

Page 17: ... Performance Counts recorded each time the Live Interval counters expire To display these performance counts from the STAT menu use the toggle switch pushbutton to select the FIBR menu item and then choose the LAST menu item The module records Last interval counts for 15 minute and 24 hour intervals The corresponding status is displayed by selecting either the 15m or 24h menu item The following se...

Page 18: ...ed on B3 error detection 4 2 1 6 Displaying the Loss of Signal seconds in Line Layer This menu displays a LOS Seconds Line counter recorded over the duration since CTRL FIBR LOSL CLR was last selected To display the LOSL counter from the STAT menu use the toggle switch pushbutton to select the FIBR menu item and then choose the LOSL menu item STAT FIBR LOSL Count Value The following indications ar...

Page 19: ...ber of Active PID s and Number of Continuity Count Errors can be displayed To display the ASI Status Information from the STAT menu use the toggle switch pushbutton to select the IASI menu and then choose one of RATE NULL DATA PID or CCER under ASI 1 8 STAT IASI ASI1 ASI8 RATE NULL DATA PID CCER 0 107 for rates 0 128 for PID s 0 9999 for error counter The following indications are possible RATE To...

Page 20: ... Packet Bit Rate DATA Useful Bit Rate PID Number of Active PID s CCER Number of Continuity Count Errors 4 2 1 12 Displaying the Output ASI Bandwidth Used This menu selection displays the sum of the 8 output channel bandwidths To display the Total Output Bandwidth Used from the STAT menu use the toggle switch pushbutton to select the OASI menu and then choose OPBW followed by USED STAT OASI OPBW US...

Page 21: ...Ethernet Speed This menu selection displays the Ethernet Transmission Speed To display the Ethernet Transmission Speed from the STAT menu use the toggle switch pushbutton to select the ETH menu and then choose SPD STAT ETH SPD 10 100 1000 DOWN The following indications are possible 10 10Mb s Ethernet Link established 100 100Mb s Ethernet Link established 1000 1000Mb s Ethernet Link established DOW...

Page 22: ...L SESP SEFS 1 to 9999 PSWD 0 to 9999 PWSL 0 to 9999 OUTP DIS EN IN1 MAXB 1 107 OUTP DIS EN IN2 MAXB 1 107 OUTP DIS EN IN3 MAXB 1 107 OUTP DIS EN IN4 MAXB 1 107 OUTP DIS EN IN5 MAXB 1 107 OUTP DIS EN IN6 MAXB 1 107 OUTP DIS EN IN7 MAXB 1 107 OUTP DIS EN IN8 MAXB 1 107 These values may only be modified if the correct passcode is entered OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUTP BACK DIS EN IASI A...

Page 23: ... use the toggle switch pushbutton to select the FIBR menu item and then choose the LASR menu item CTRL FIBR LASR CONT DISC The following selections are available CONT Laser is on regardless of input DISC Laser is on with signal present and off with no signal present 4 2 2 3 Setting the Clock Source Three clock settings are available for serial fiber output To configure the Clock Source from the CT...

Page 24: ...e available CESR CLR to clear all Error Ratios 4 2 2 5 Setting the Severe Errored Second Threshold The Severe Errored Second SES threshold can be controlled using menu selections To configure the SES Threshold from the CTRL menu use the toggle switch pushbutton to select the FIBR menu item and then choose the SETH menu item CTRL FIBR SETH SESS SESL SESP SEFS 1 to 9999 The following selections are ...

Page 25: ... select the PSWD menu item and then choose from the IN1 IN8 menu item followed by OUTP menu item CTRL PSWD IN1 IN8 OUTP EN DIS The following selections are available EN Enable Input Channel DIS Disable Input Channel When Disabled the data input on the selected signal is not placed on the fiber link data stream To configure Input Channel Bandwidth from the CTRL menu use the toggle switch pushbutton...

Page 26: ...e Orientation of the Text on the Card Edge Display The text orientation can be controlled using menu selections To configure the text orientation from the CTRL menu use the toggle switch pushbutton to select the DISP menu item CTRL DISP HORZ VERT The following selections are available HORZ Horizontal display VERT Vertical display ...

Page 27: ...w the locations of the jumpers on the top board and bottom boards respectively FRAME STATUS MODULE OK LOCAL FAULT RUN UPGRADE J2 SERIAL ON OFF PUSH BUTTON TOGGLE SWITCH Output Video Status 1 6 2 3 4 5 7 8 Payload Figure 5 1 Location of Status Indicators and Jumpers Top Board FRAME STATUS MODULE OK LOCAL FAULT RUN UPGRADE J2 SERIAL ON OFF Input Video Status 1 6 2 3 4 5 7 8 Figure 5 2 Location of St...

Page 28: ...e Jumper UPGRADE The UPGRADE jumper is used when firmware upgrades are being done to the module For normal operation it should be installed in the RUN position See the Upgrading Firmware section of this manual for more information To upgrade the firmware in the module unit pull it out of the frame Move the UPGRADE jumper into the UPGRADE position Install the Upgrade cable provided located in the v...

Page 29: ...ceive feedback that the configuration has been carried out There are 3 components of SNMP 1 An SNMP manager also known as a Network Management System NMS is a computer running special software that communicates with the devices in the network Evertz VL Fiber demo Manager graphical user interface GUI third party or custom manager software may be used to monitor and control Evertz VistaLINK enabled ...

Page 30: ...gnal Total TS Bit Rate Null Packet Bit Rate Useful Bit Rate Number of Active PID s and Number of Continuity Count Errors Link Input Status Indicates Link Input Status Clock Reference Indicates the current clock reference set as source Errored Seconds Current and Last Indicates the errored seconds occurred in 15 min and 24 hr time intervals Severe Errored Seconds Indicates the severe errored second...

Page 31: ...f with no valid input signals In Continuous mode the laser will continuously transmit and maintain the link to the companion 7707VB 8 ASI OC3 Reference Allows the user to select Oscillator Link or Auto mode for clock settings Change Passcode Setup the Passcode used to access the Video Blocking features Threshold Allows the user to set Optical Level and Errored Seconds Threshold Video Block Allows ...

Page 32: ...andwidth is exceeded Input and Output Continuity Count Error Triggers when Input or Output 1 8 detects Continuity Count Errors Laser Fault Triggers when laser fault is detected Link Loss Triggers when a link loss is detected Severe Errored Second Triggers when one or all of severe errored thresholds are crossed Errored Second Triggers when Line Path or Section errored second is present Ethernet Li...

Reviews: