evertz 5700MSC Quick Start Manual Download Page 3

 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

 

The lightning flash with arrowhead symbol within an equilateral triangle is 
intended to alert the user to the presence of uninsulated “Dangerous voltage” 
within the product’s enclosure that may be of sufficient magnitude to 
constitute a risk of electric shock to persons. 

 

The exclamation point within an equilateral triangle is intended to alert the 
user to the presence of important operating and maintenance (Servicing) 
instructions in the literature accompanying the product. 

 

  Read these instructions 

  Keep these instructions. 

  Heed all warnings. 

  Follow all instructions. 

  Do not use this apparatus near water 

  Clean only with dry cloth. 

  Do not block any ventilation openings.  Install in accordance with the manufacturer’s instructions. 

  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus 

(including amplifiers) that produce heat. 

  Do not defeat the safety purpose of the polarized or grounding-type plug.  A polarized plug has two 

blades with one wider than other.  A grounding-type plug has two blades and a third grounding 
prong.  The wide blade or the third prong is provided for your safety.  If the provided plug does not 
fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

  Protect the power cord from being walked on or pinched particularly at plugs, convenience 

receptacles and the point where they exit from the apparatus. 

  Only use attachments/accessories specified by the manufacturer 

  Unplug this apparatus during lightning storms or when unused for long periods of time. 

  Refer all servicing to qualified service personnel.  Servicing is required when the apparatus has 

been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled 
or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does 
not operate normally, or has been dropped. 

 

WARNING 

TO REDUCE THE RISK OF FIRE OR ELECTRIC – SHOCK, DO NOT EXPOSE THIS APPARATUS 
TO RAIN OR MOISTURE 

WARNING

 

DO NOT EXPOSE THIS EQUIPMENT TO DRIPPING OR SPLASHING AND ENSURE THAT NO 
OBJECTS FILLED WITH LIQUIDS ARE PLACED ON THE EQUIPMENT 

WARNING

  

TO COMPLETELY DISCONNECT THIS EQUIPMENT FROM THE AC MAINS, DISCONNECT THE 
POWER SUPPLY CORD PLUG FROM THE AC RECEPTACLE 

WARNING

  

THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY OPERABLE 

 

 

Summary of Contents for 5700MSC

Page 1: ...erty of Evertz Microsystems and is intended solely for the use of purchasers of the 5700MSC Master Clock product Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 5700MSC Master Clock product Due to on going research and development features and specifications in this manual are subject to change without notice All rights reserved No par...

Page 2: ...This page left intentionally blank ...

Page 3: ...ird grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manuf...

Page 4: ... Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicati...

Page 5: ...ranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed in relation to any errors or omissions unless specifically undertaken in the...

Page 6: ...Model 5700MSC Master Clock System Page ii Revision 1 0 This page left intentionally blank ...

Page 7: ...NECTING FREQUENCY REFERENCES 2 1 5 SELECTING AND CONNECTING TIME REFERENCES 3 1 6 CHECKING THE STATUS OF THE UNIT 4 1 7 WIRING THE OUTPUTS 4 1 8 CONFIGURING THE SYNC OUTPUTS 5 1 9 CONFIGURING THE TEST GENERATOR OUTPUTS 5 1 10 CONFIGURING THE TIME OUTPUTS 5 1 11 FINAL STEPS OF SET UP AND SECURING ALL CONNECTIONS 6 1 12 ACCESS CONTROL 6 Figures Figure 1 1 5700MSC Front Panel 1 Figure 1 2 5700MSC Rea...

Page 8: ...Model 5700MSC Master Clock System Page iv Revision 1 0 This page left intentionally blank ...

Page 9: ...ld be powered from different AC sources for true redundancy If both supplies are not powered the unpowered supply will trigger a system fault A redundant power supply may be added at any time to a unit by removing the fan module and installing the second power supply The power supplies and fan module are hot swappable and accessed from the front of the unit by removing the front panel Each power s...

Page 10: ...should now be accessible and SNMP can be enabled through SNMP Ctl The trap addresses must be assigned if SNMP traps are required to be sent to remote logging software such as VistaLINK Pro Contact Evertz customer service if a MIB to the 5700MSC is required 1 4 SELECTING AND CONNECTING FREQUENCY REFERENCES Pressing the INPUT button on the front panel will select the input menu From here the frequen...

Page 11: ...an synchronize with a PTP master to determine a frequency reference There are three other menu items that control how the 5700MSC locks to its reference These are Genlock Range Genlock Source and Lock type Press the HELP button for a short description on what each menu item does 1 5 SELECTING AND CONNECTING TIME REFERENCES Once the desired frequency reference has been selected and the antenna refe...

Page 12: ...e unit can be checked by pressing the STATUS button on the front panel There are several different status screens which can be selected by using the control knob or the and buttons The status of the frequency and time references can be viewed by choosing the Lock status screen and pressing SELECT Press ESC to return to the status menu to select another screen for viewing Any screen name that is hi...

Page 13: ...ll be automatically locked in frequency and phase The test generators are independent from one another and can be configured to different formats and different phase offsets By default all phases will be aligned to the selected frequency reference The unit also has two 10GbE ports that can output test generators if the 10G TG option is ordered Each 10GbE port can output 3 test generators which can...

Page 14: ...nu items 1 11 FINAL STEPS OF SET UP AND SECURING ALL CONNECTIONS Once the 5700MSC has been configured the various STATUS screens should be checked to ensure there are no items displayed with a red or yellow background The left LCD screen should show Sys OK and Ref OK with a green background in the bottom corners The power supply and fan modules accessed by removing the front panel should be secure...

Reviews: