1200DD Series Digital Data Display Manual
Revision 1.8
1200DD - 3-19
3.4.12.9. Selecting the Trap IP
IC
With this menu item, you can select the trap that the TA instruction affects.
There are 4 trap addresses that can be used.
If the trap address indicated by this is set, then there will be an “I” before
the number. For example if traps 1 and 3 have their IP addresses set, as
this item is scrolled through, it would show:
“i1”
“ 2”
“i3”
“ 4”
TS
1
2
3.
4
3.4.12.10. Setting the Trap Internet Address
IC
With this menu item, you can set the IP address that the 1200DD will send
traps to.
There are 4 IP addresses that can be set. This operates on the one
pointed to by TS.
See section 3.4.12.2 for IP setting instructions. The default is 0.0.0.0.
When the address is entered, you will be returned to the TS menu above to
facilitate entering multiple trap addresses.
TA
xxx.yyy.zzz.aaa
3.4.12.11. Enabling Traps
IC
With this menu item, you can enable trap sending.
When set to On, a trap will be sent to all IP addresses set in Selecting the
Trap IP when reference is obtained or lost.
TE
On
Off
3.4.12.12. Setting the Timer Port
IC
With this menu item, you can set port number for receiving Evertz Timer
packets The range is 1025 to 65535. The default setting is 6990
PT
xxxxx