EVERSPRING USC423A User Manual Download Page 5

 

- 5 - 

c.  If a device signal is received in Test Mode the doorbell would sound and 

indicate with LEDs 1 to 9 (LED 1 – 9 indicates Sensor Zone 1 – 9, Remote 
1 – 9, or Tag 1 – 9. Other indications would be LED 0) 
If the device is a sensor, the Sensor Type will be indicated as below: 
Arm LED on: indicates the Sensor will only trigger when Fully Armed 
Partial LED on: indicates the Sensor will trigger when Fully Armed or 
Partial Armed 
Alarm LED on: indicates the Sensor will trigger an immediate alarm (24 
hours) when Fully Armed / Partial Armed / Disarmed. 

d.  Press 7 for 3 or more seconds during Test Mode would display the GSM 

signal strength indicated as: LED 1 (Good), LED 2 (Normal), LED 3 (Poor), 
LED 4 (No Signal / SIM card registration failure / No SIM card).   

e.  Press 8 for 3 or more seconds during Test Mode would send a System On 

/ Off command from the Wireless Siren.   

f.  Press 9 for 3 or more seconds during Test Mode would send a test SMS 

(including the current Alarm Mode, Delay Time, Siren On/Off, and Alarm 
Time) to the host mobile phone number. 

 

3-7 Alarm Procedure:   

When an alarm is triggered the Alarm LED will flash and the alarm will 
sound (depending on your Alarm Type and Alarm Time settings) with an 
SMS / call notification (depending on your Alarm message and SMS 
setting). LEDs 1 – 9 will also indicate Sensor Zone 1 – 9, Remote 1 – 9, or 
Tag 1 – 9. LED 0 will light on for other situations. For Alarm LED, enter 
“Pa Disarm Key” to clear Alarm Memory. The default time for 
Siren Alarm is 3 minutes. 

 

3-8 Open Door / Window Alert:

   

When set to On and entering Fully Armed or Partial Armed, the door / 
window sensors will be checked depending on alarm mode. If sensor 
shows Open then the device will beep 10 seconds, and the LED will show 
1 – 9 for Sensors 1 – 9 (0 for other Sensor Zones). After the alert has 
ended it will enter the configured warning procedure (if all doors / windows 
are normal the alert sounds will turn off).   

      You may also check beforehand: 
      Pressing the Arm Key will check all doors and windows under Fully Armed 

and display LED opened doors or windows for 3 seconds. 

      Pressing the Partial Arm Key will check all doors and windows under 

Partial Armed and display LED opened doors or windows for 3 seconds. 

 

3-9 RF Anti-Jamming Function 

When Anti-jamming is set to on, the device will send an SMS to the Host 
Phone Number when RF jamming is detected under Arm Mode.   

 

3-10 One Key Alarm Mode 

      Under Disarm Mode: 
      Press Arm Key for 3 or more seconds to enter Arm Mode; 
      Press Partial Arm Key for 3 or more seconds to enter Partial Arm Mode. 
 

3-11 Disarm Threat Password 

Threat Password is your normal pa 1. 
For example: normal password 1230 will have a threat password of 1231 
Normal password of 9999 will have a threat password of 0000. 
An SMS will be sent to the Host Phone Number when using a threat 
password to disarm. 
 

3-12 Sensor Low Battery Indication 

      When a Sensor Low Battery signal is received an SMS will be sent to Host 

Phone Number (The sensor will send a second SMS after a minimum 
interval of 7 days).   

 

3-13 Restore to factory settings with the Reset button: 

a.  Turn off all power 
b.  Press and hold the Reset button (next to the DC-Jack) then restart the 

device. One beep will sound. 

c.  5 beeps will sound to indicate the device has been restored to factory 

settings. 

d.  Default password is: 1234. For other default values please see the Quick 

Guide. 

 

4. Alarm Message Playback and SMS Functions 

Device SIM card setup and installation instructions: 

a.  Unlock the SIM card before use. PIN code or PUK code not required. 
b.  Do NOT set the SIM card phone number to host phone number or regular 

SMS phone number.   

c.  Ask your local carrier to disable voice message function of this SIM card. 
d.  As  alarm  messages  and  sending  SMS  require  fees,  please  inquire  with 

your local carrier about their charging standards. 

Summary of Contents for USC423A

Page 1: ...d a key tone will sound when Key Tone is enabled 3 1 Definition of LEDs LED Indication GSM Signal LED Flashing once every second Registering with host device Flashing once every three seconds Successful registration with host device Off No AC power REC LED Flashing Recording On Playback Monitoring On Speaker playback ARM LED On Arm Mode Flashing Arm Mode Exit Delay PARM LED On Partial Arm Mode Fla...

Page 2: ... Dialer nter password 01 Default is ON Alarm Type 2 No siren Dialer only Enter password 02 Siren will not sound during alarm DISARM Mode Disarm Key flashes Test Mode Enter password 03 A doorbell sound will be generated when a device signal is received Hold key 7 for 3 or more seconds Test GSM receiving signal strength Hold key 8 for 3 or more seconds Turn on off the Wireless Siren Hold key 9 for 3...

Page 3: ...er will cause an Entry Delay Add Devices 24HRs Intruder Mode Enter password 15 4 Sensors triggered when Disarmed Partial Armed Fully Armed will cause an immediate alarm 24 hours Note Fire Sensors Flood Sensors must choose this Type 24 hours Delete Sensor Enter password 20 Key 1 Delete all sensors Enter password 20 Key 1 1 9 Delete sensor 1 9 Enter password 20 Key 1 0 Delete all sensors after 10 De...

Page 4: ...A long beep will sound if the password is correct Three beeps will sound if the password is incorrect b If the password is correct the system will enter the Exit Delay countdown The Arm LED and beep tone will flash and sound once every second c When the countdown reaches 5 second the beep tone will sound twice every second d After the countdown is complete the system will time out and enter Arm Mo...

Page 5: ...he configured warning procedure if all doors windows are normal the alert sounds will turn off You may also check beforehand Pressing the Arm Key will check all doors and windows under Fully Armed and display LED opened doors or windows for 3 seconds Pressing the Partial Arm Key will check all doors and windows under Partial Armed and display LED opened doors or windows for 3 seconds 3 9 RF Anti J...

Page 6: ...essage will automatically call and notify the user of an alarm condition Please refer to the Trigger Call Procedures 4 2 3 System Disarm Notification When the RFID Tag is on the Host tag sensor an SMS will be sent to the Host Phone Number if Fully Arm is set to Disarm and notify the user on who disarmed the system 4 3 Built In Automatic Voice Dial 4 3 1 How to enter Reverse Control The user may pr...

Page 7: ...4 Call back from Alarm system console Note 7 System Status Display 00 System Disarmed System Armed System Partial Armed Entry Exit Delay Time xx Seconds Siren Volume Mute Low High Siren Ringing Time xx Minutes Set Alarm Voice Phone Number 5 Note1 Note 5 TEL 1 2 3 4 5 Forward Edit Send TEL 1 0932XXXXXX 2 0922XXXXXX 3 0928XXXXXX 4 0965XXXXXX 5 0932XXXXXX Set Phone Number Successfully Set Alarm SMS P...

Page 8: ... Change Zone 2 Name 92 Note 2 Note5 Zone2 Name Zone2 Forward Edit Send Zone2 Name Entrance Door Sensor2 Set Zone Name Successfully Change Zone 3 Name 93 Note 2 Note5 Zone3 Name Zone3 Forward Edit Send Zone3 Name Entrance Door Sensor3 Set Zone Name Successfully Change Zone 4 Name 94 Note 2 Note5 Zone4 Name Zone4 Forward Edit Send Zone4 Name Entrance Door Sensor4 Set Zone Name Successfully Change Zo...

Page 9: ... Name Entrance Door Sensor8 Set Zone Name Successfully Change Zone 9 Name 99 Note 2 Note5 Zone9 Name Zone9 Forward Edit Send Zone9 Name Entrance Door Sensor9 Set Zone Name Successfully Change RFID Tag Names 10 Note 2 Note5 Tag Names 1 2 3 4 Forward Edit Send Tag Names 1 Jack 2 Daniel 3 Henry 4 Joe Set Tag Names Successfully Set Entry exit Delay Time 11 Note 5 Entry Exit Delay Time 0 240 sec 15 For...

Page 10: ...d Status Report SMS Sent SMS in Return AC Adaptor Power Off Note 6 System AC Power Loss AC Adaptor Power On Note 6 System AC Power Return Tag Disarmed Note 6 For Tag 1 Tag 4 Send Tag name For Other Tags Send Tag xx Zone Trigger For Zone 1 Zone 9 Send Zone name is triggered For Other Zones Send Zone xx is triggered Zone Tamper For Zone 1 Zone 9 Send Zone name tamper is triggered For Other Zones Sen...

Page 11: ...uthorized mobile phone number to receive the host model number and software version 5 Troubleshooting 5 1 System Reset The user may use the system reset button to return the device to factory default settings The default password is 1234 Please note that all configurations including recorded alarm messages contact lists and learnt ID codes will be deleted a Take the device off the wall b Remove al...

Page 12: ... AC power insert them back and try again Specifications Operating temperature range 10 C to 50 C Operating humidity 85 RH at 30 C Adapter 9V DC 1A Battery type Li ion cell 2000mAh 3 7V Transmission range Outdoors 150m Open space for front and sides Frequency range 868 35 MHz Specifications are subject to change without notice USC423A0517 ENVIRONMENTAL CONCERNS Please DO NOT dispose of electrical a...

Reviews: