Troubleshooting 
 

Symptom 

Possible Cause 

Recommendation 

LED not illuminating, the 

detector not working 

Run out of battery power; check if 

reverse battery polarity 

Replace a new battery 

Check  if  the  detector  is  out  of 

order 

Do  not  open  the  detector; 

send it to the local retailer. 

LED cannot display and the 

detector not working when 

pressing the test button 

Reverse  battery  polarity  or  poor 

battery connections 

 

Refit the battery with correct 

polarity 

Run out of battery power 

Replace a new battery 

Button  pressing  time  is  not  long 

enough; it should be pressed and 

held for more than 1 second 

Press and hold the button for 

longer than 1 second 

The detector does not stay 

awake for 10 minutes when 

power is first supplied 

Check if detector is out of order 

Remove  the  battery,  press 

link  key  several  times  to 

release  the  existing  battery 

power and wait for approx.10 

seconds before replacing the 

battery. 

 

Specifications* 
 

Operating Frequency 

908.42 MHz 

Battery Type 

3V CR123A battery x 1 

Battery Life 

2 years** 

Alarm Audibility 

85db@3m 

Operating Range 

30 meters open space (indoor) 

Alarm Temperature 

57°C - 65°C (134°F - 149°F) 

Operation Temperature 

0°C - 49°C (32°F - 120°F) 

Relative Humidity 

10 - 85% 

Size 

120mm (diameter) x 5.3mm (depth) 

*Specifications are subject to change without notice 

**1 trigger per day                               

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A501112066R 

2013/07

 

 
 

 

 

 

   

                                   

 
 

 

WARNING: 

Do  not  dispose  of  electrical  appliances  as  unsorted  municipal  waste,  use 
separate collection facilities. 
 
Contact your local government for information regarding the collection systems 
available. 
 
If  electrical  appliances  are  disposed  of  in  landfills  or  dumps,  hazardous 
substances can leak into the groundwater and get into the food chain, damaging 
your health and well-being. 
 
When replacing old appliances with new ones, the retailer is legally obligated to 
take back your old appliance for disposal at least for free of charge. 

Summary of Contents for SF813

Page 1: ...hen power is first applied to allow time for configuration This unit supports the Auto Inclusion function when power is applied and no node ID is stored in the memory The Detector may automatically execute the function of inclusion when Auto Inclusion 1 The power is applied for the first time and no node ID has been stored in the detector 2 The execution of exclusion reset is successful where the ...

Page 2: ... hospitals nursing homes or group homes of any kind even if they were once single family homes For complete coverage in residential units the detector should be installed in all rooms halls storage areas basements and attics in each family living unit Minimum coverage is one detector on each floor and one in each sleeping area Useful tips are listed as the following 1 Install a detector in the hal...

Page 3: ...ts upon cooling which can cause nuisance alarms Install detectors at least 10 feet 3 meters away from bathrooms 5 In very cold or very hot areas including unheated buildings or outdoor rooms If the temperature goes above or below the operating range of smoke detector it will not work properly The temperature range for your smoke detector is 0 C to 49 C 32 F 120 F 6 In very dusty or dirty areas dir...

Page 4: ...fter the detector is installed with battery and mounted with bracket 2 4 seconds This means the smoke alarm is working normally and also indicates that the battery is positioned properly Close cover and then press the test button holding it down for about 3 seconds until the horn sounds The horn should sound a loud pulsating alarm This means the unit is working properly Operation Standby Mode The ...

Page 5: ...t occurs Group1 Commands 1 1 Smoke Event Report Once the detector is triggered by smoke the detector will send SENSOR_ALARM_REPORT command Sensor Type 0x01 Sensor State 0xFF to the node of Group1 to inform there is a smoke event The command will be re sent if the node of Group1 does not receive the signal When the event is cleared the detector will send SENSOR_ALARM_REPORT command Sensor Type 0x01...

Page 6: ... existing battery power and wait for approx 10 seconds before replacing the battery Specifications Operating Frequency 908 42 MHz Battery Type 3V CR123A battery x 1 Battery Life 2 years Alarm Audibility 85db 3m Operating Range 30 meters open space indoor Alarm Temperature 57 C 65 C 134 F 149 F Operation Temperature 0 C 49 C 32 F 120 F Relative Humidity 10 85 Size 120mm diameter x 5 3mm depth Speci...

Reviews: