EVERSPRING SF813 Manual Download Page 4

 

4

WARNING

:  Do  not  stand  close  to  the  detector  when  the  alarm  is  sounding.   

The alarm is loud in order to wake you in an emergency.    Too much exposure 
to the horn at close range may be harmful to your hearing. 

 
 
Installation 
 

Battery Installation 

1.  Open battery compartment (see item

 in product overview). 

2.  Install battery into compartment and make sure the “+” and “-“ ends of each 

battery are aligned properly.   

3.  After  battery  is  installed  in  compartment,  you  will  hear  a  chirp  which 

indicates the unit is receiving battery power.   

 

Unit Installation 

1.  At the place where you are going to install the detector, draw a horizontal line 

six inches long. 

2.  Remove  the  mounting  bracket  from  the  detector  by  rotating  it 

counterclockwise.   

3.  Place the bracket so that the two longest hold slots are aligned on the line. In 

each of keyhole slots, drawing a mark to locate a mounting plug and screw. 

4.  Remove the bracket. 
5.  Using a 3/16-inch (5mm) drill bit, drill two holes at the marks and insert plastic 

wall plugs.    Put the detector away from getting plaster dust on it when you drill 
holes for mounting. 

6.  Using the two screws and plastic wall plugs supplied, fix the bracket to the wall.   
7.  Line up the slot of the bracket with the detector.    Push the detector onto the 

mounting bracket and turn it clockwise to fix it into place.    Pull outward on the 
detector to make sure it is securely attached to the mounting bracket. (FIGURE 
7) 

 
 
 
 
 
 
 
 
 

FIGURE 7 

 

CAUTION:

 

This  smoke  alarm  comes  with  cover  latches  that  will  prevent  the 

smoke alarm cover from closing if battery is not installed. This tells you that the 
smoke alarm will not work until a new battery is properly installed.   
 

NOTE: 

alarm horn will beep once after the detector is installed with battery and 

mounted  with  bracket  2-4  seconds.  This  means  the  smoke  alarm  is  working 
normally and also indicates that the battery is positioned properly. Close cover, 
and  then  press  the  test  button,  holding  it  down  for  about  3  seconds  until  the 
horn sounds. The horn should sound a loud, pulsating alarm. This means the 
unit is working properly. 
 
 

Operation 

 
Standby Mode 

The red LED, as the ALARM indicator, can be seen through the clear test button 
on  the  cover  of  the  unit.  When  the  red  LED  flashes  once  334  seconds,  it 
indicates  the  smoke  detector  is  under  normal  operation.  When  the  detector 
senses smoke, the unit will instantly sound an audible alarm with 3 beeps, pause, 
and then 3 beeps. The red LED will also flash continuously and rapidly. 

 
Silence Feature 

The silence function can temporarily quiet an alarm for up to 10 minutes. To use 
this feature, press the test/silence button on the cover when it alarms. However, 
if the smoke concentration around the detector is still at alarming level after 10 
minutes of silence, the unit will re-alarm immediately. 
 

Low Battery Warning Signal 

If  the  alarm  horn  begins  to  beep  once  in  43  seconds  with  LED  flashing,  this 
signal means that the detector’s battery is weak. This low battery warning signal 
should last for up to 30 days, but you should replace the battery immediately to 
secure your protection. 
 

Tamper Switch Feature 

If the smoke detector is not mounted into the bracket properly within 5 minutes 
after battery is installed, the tamper function is triggered and the Yellow LED is 
steadily  on.  If  the  smoke  alarm  is  still  not  mounted  into  the  bracket  properly  5 
minutes after battery is installed, you will hear temporal three sounds with yellow 
LED steadily on until smoke alarm is mounted back into bracket properly. 
 

Mounting 

  bracket

 

Test / Silence Button   

  Power / Smoke Alarm 

LED indicator 

Summary of Contents for SF813

Page 1: ...hen power is first applied to allow time for configuration This unit supports the Auto Inclusion function when power is applied and no node ID is stored in the memory The Detector may automatically execute the function of inclusion when Auto Inclusion 1 The power is applied for the first time and no node ID has been stored in the detector 2 The execution of exclusion reset is successful where the ...

Page 2: ... hospitals nursing homes or group homes of any kind even if they were once single family homes For complete coverage in residential units the detector should be installed in all rooms halls storage areas basements and attics in each family living unit Minimum coverage is one detector on each floor and one in each sleeping area Useful tips are listed as the following 1 Install a detector in the hal...

Page 3: ...ts upon cooling which can cause nuisance alarms Install detectors at least 10 feet 3 meters away from bathrooms 5 In very cold or very hot areas including unheated buildings or outdoor rooms If the temperature goes above or below the operating range of smoke detector it will not work properly The temperature range for your smoke detector is 0 C to 49 C 32 F 120 F 6 In very dusty or dirty areas dir...

Page 4: ...fter the detector is installed with battery and mounted with bracket 2 4 seconds This means the smoke alarm is working normally and also indicates that the battery is positioned properly Close cover and then press the test button holding it down for about 3 seconds until the horn sounds The horn should sound a loud pulsating alarm This means the unit is working properly Operation Standby Mode The ...

Page 5: ...t occurs Group1 Commands 1 1 Smoke Event Report Once the detector is triggered by smoke the detector will send SENSOR_ALARM_REPORT command Sensor Type 0x01 Sensor State 0xFF to the node of Group1 to inform there is a smoke event The command will be re sent if the node of Group1 does not receive the signal When the event is cleared the detector will send SENSOR_ALARM_REPORT command Sensor Type 0x01...

Page 6: ... existing battery power and wait for approx 10 seconds before replacing the battery Specifications Operating Frequency 908 42 MHz Battery Type 3V CR123A battery x 1 Battery Life 2 years Alarm Audibility 85db 3m Operating Range 30 meters open space indoor Alarm Temperature 57 C 65 C 134 F 149 F Operation Temperature 0 C 49 C 32 F 120 F Relative Humidity 10 85 Size 120mm diameter x 5 3mm depth Speci...

Reviews: