background image

Manual Binding 

1.

 

Locate the Control Box area and remove its waterproof cover by

unscrewing it. 

Identify the Link button inside.

2.

With the 9V battery still connected, repeat steps 5 to 6 of the Binding with
Homesys section.

3.

Press and hold the Link Button for more than 4 seconds until the Strobe LED
starts to flash rapidly then release.

4.

Within 5 seconds the Strobe LED will stop flashing and turn off, indicating the
binding procedure is completed. The screen below will appear to confirm this.

Reset to Factory Settings 

1.

Press and hold the Link Button for more than 4 seconds until the Strobe LED
starts to flash rapidly then release.

2.

Press and hold the Link button again for more than 6 seconds until the Strobe
LED turns off, then release. The LED will flash every 2 seconds indicating the
siren is now reset back to factory mode factory.

Jumper Settings 

The siren preset settings can be modified by adjusting the jumper settings inside its 
Control Box.   

1.

Locate the Control Box area and remove its waterproof cover by unscrewing it.

2.

Identify the set of jumper links JP1. The settings for each is described below:

Position

Jumper fitted 

Jumper removed 

ALARM 

Alarm sound enabled 

Alarm sound disabled 

CU 

Must be fitted 

N/A , factory use only 

1MIN 

1 minute alarm sound 

3 minute alarm sound 

ANTI 

Anti-jamming enabled 

Anti-jamming disabled 

BEEP 

Beep sound enabled 

Beep sound disabled 

JP1

Beep

A.J.

1 MIN

C.U.

Alarm

JP1 Settings

Control 
Box 
Cover 

Link Button

Summary of Contents for SE801

Page 1: ...SE801 User manual Manuale utente Gu a de usuario...

Page 2: ...g the fixing screw from the bottom edge and carefully peeling off the back cover All electronic components are housed within the front cover 2 A 9V Alkaline battery is supplied to boost the initial po...

Page 3: ...the siren facing up on a flat surface so that the protruding tamper switch is pressed 3 Set the system to Arm mode and trigger the alarm The siren will emit a loud piercing sound and the strobe light...

Page 4: ...o click If the switch does not close this will prevent the Siren from operating correctly If necessary remove the main body again and adjust the screw on the back cover tamper plunger to ensure the sw...

Page 5: ...en release 2 Press and hold the Link button again for more than 6 seconds until the Strobe LED turns off then release The LED will flash every 2 seconds indicating the siren is now reset back to facto...

Page 6: ...100dB 1 meter Operating Frequency 868MHz EU 923MHz America Specifications are subject to change without notice WARNING Do not dispose of electrical appliances as unsorted municipal waste use separate...

Page 7: ...ponenti poste all interno 2 La batteria da 9V serve solo per la prima accensione bisogna lasciare la sirena sotto i raggi solari per qualche tempo fino a che la batteria principale sia carica Individu...

Page 8: ...ata verso l alto in modo che il sensore anti vandalismo resti premuto 3 Armare il sistema ed attivare un allarma La sirena dovrebbe suonare con il lampeggiante acceso 4 Disarmare il sistema per disatt...

Page 9: ...ona correttamente Se necessario rimuovere la sezione principale e fissare la base in modo che il sensore anti vandalismo resti ben premuto 11 Una volta terminata l installazione il LED si illumina per...

Page 10: ...muto il bottone di ricerca per piu di 6 secondi fino a quandi l LED si spegne Se il LED lampeggia ogni 2 secondi il processo stato completato Impostazioni interne Alcune impostazioni della sirena poss...

Page 11: ...inimo 100dB ad 1 metro Frequenza wireless 868MHz EU 923MHz America Le specifiche sono soggette a modifiche senza preavviso PRECAUZIONI Non gettare dispositivi elettronici come normali rifiuti utilizza...

Page 12: ...las partes electr nicas est n en esa parte de la caja 2 La bater a 9V alkalina sirve para encender la sirena durante el instalaci n mientras el panel solar esta cargado la bateria recargable 6V Busca...

Page 13: ...nillo de abajo 2 Poner la sirena cara arriba en una superficie llana de modo que el bot n anti manipulaci n quede presionado 3 Configurar el sistema en armado y disparar el alarma La sirena emite un s...

Page 14: ...sionado en la pared se va a escuchar un clic Si no est bien presionado puede influenciar el correcto funcionamiento Si es necesario quitar la caja principal y cambiar la posici n de los tornillos 8 Te...

Page 15: ...undos hasta que el LED Strobe se apaga El LED parpadea cada 2 segundos para indicar que la sirena ha vuelto a valores de f brica Configuracion pines caja de control La configuraci n b sica de la siren...

Page 16: ...ecificaciones Bater a 6V 1 2Ah Plomo cido 9V PP3 alkalina Temperatura operativa 10 C to 60 C Volume sirena Minimo 100dB 1 metro Frequencia radio 868MHz UE 923MHz America Las especificaciones est n suj...

Reviews: