- 2 -
4.2 Inclusion:
Press “ ” and operate the device as shown.
Successful binding will be listed in the device list as shown below:
4.3 Exclusion
Press “ ” and operate the device as shown. Device exclusion will be shown in
the message log:
5. Functions and Report screen
5.1 Select a device and choose the “Command Class” tag. Commands supported by
this device will be shown.
5.2 Select “COMMAND_CLASS_ASSOCIATION” -> “ASSOCIATION_SET”, set
“Grouping identifier” and “Node ID” to “01”, then press “Send”. The device will now
report back to the controller.
5.3 History data of controller transmittance and acceptance can be checked from the
“Log” screen.
Troubleshooting
Possible
Cause
Solution
Unable to Pair
Device is controlled
incorrectly.
See the device menu and
check the pairing
procedures.
RF signal interference.
Operate again when there
is no interference.
Pairing successful, but the
device cannot be
controlled or the device
report cannot be received.
The maximum distance
between the USB dongle
and the device has been
exceeded.
Shorten the distance
between the USB dongle
and device.
RF signal interference.
Operate again when there
is no interference.
Specifications
Operating Voltage
4.75 – 5.25V
Operating Temperature
Range
-10 to 50°C (Indoor use only)
Storage Temperature
Range
-20 to 60°C
Humidity 85%RH
Interface USB
Operating Range
Up to 100m line of sight
WARNING:
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities instead.
Please contact your local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging your health and well-being.
When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance