3
2. AC input :
AC220~240V/50Hz Europe Australia AC100~120V/60Hz US
3. The suitable ambient temperature for the Module is 0 C~40 C.
4. Do not locate the Module where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
5. After putting it into use, the body of Module will become a little bit hot of which
phenomenon is normal.
Installation
Note:
Please note that it is a must to call for a licensed electrician for installation.
Install this Module into a wall box of which wiring connection is shown hereunder:
HAC01 can be installed into the in-wall power box, the power cord have to be
connected to the main AC power, the manual switch input cable is wired to normal
NO (open) / NC (close) button or switch. When the wiring connection is completed,
please follow the previous instruction to operate the Inclusion and Association
process to finish HAC01’s connection and network setting with controlled device (ex.
HAN01).
Troubleshooting
Symptom
Cause of Failure
Recommendation
The Module not working
and LED off
1. Improper wiring
connection
1. Check power connections
2. Don’t open up the Module and
2. The Module break
down
send it for repair.
The Module LED
illuminating, but cannot
control the ON/OFF
Switch of the load attached
Check if the load
connected to the Module
has its own ON/OFF
switch
Set the ON/OFF switch of the
load connected to ON
The Module LED
illuminating, but the
Detector cannot control
the Module
1. Not carry out
association
2. Same frequency
interference
1. Carry out association
2. Wait for a while to re-try
Specification
Power Input
AC 100~240 V/50~60Hz
AC220~240V/50Hz Europe Australia AC100~120V/60Hz US
RF Operation Range
Minimum 30 m indoor line of sight
Operating Temperature 0 C ~ 40 C
Frequency Range
868.42 MHz Europe 908.42MHz US 921.42MHz Australia
** Specifications are subject to change and improvement without notice.
Model number information
HAC01-0 US 908.42MHz
HAC01-1 Europe 868.42MHz
HAC01-2 Australia 921.42MHz
Warning:
Do not dispose of electrical appliances as unsorted municipal waste, use separate
collection facilities.
Link button
AC power
input
Manual switch input