SPECIFICATION (
電氣規格
)
Model Number
:
HA51 (FCC)
*1. Adaptor Spec.
:
DC 15V / 300mA
2. Standy Current
:
60mA Max.
3. Operating Current
:
110mA Typ. 120mA Max. (Expect External Load)
4. External Output Power (POWER+)
:
12.8
±
1 V / 100mA Max.
5. Alarm Auto-Stop Time
:
3 Min.
±
30 Sec. / 10 Min.
±
1 Min. (selectable)
6. Alarm Volume
:
95 dB Min. (The front of 1M)
7. Battery Voltage
:
14
±
1 VDC (Except 12V 1.2AH Battery & External Output)
8. Exit/Entry Time
:
15
±
3 Sec.
*9. P+ Voltage
:
12.8
±
1V/250mA (Add 12V/1.2AH Rechargeable Battery).
Option:
1. Adaptor Spec.
:
DC 16V / 600mA.
2. Backup Battery Spec.
:
DC 12V 1.2AH Rechargeable battery.
3. ANTI Jamming act time
:
30
±
15 Sec. (Add ANTI Jamming module).
*4. P+ Voltage
:
12.8
±
1V/500mA (Add 12V/1.2AH Rechargeable Battery).
5. Alarm Auto-stop Time
:
3 Min.
、
10 Min. (2 step selectable).
6. Receiver Frequency
:
433MHz
7. Receiver Range
:
70M Min. (For free space which is transmitted by HA51M or HA51P),
60M Min. (For free space which is transmitted by HA51R).
(Old Version 70M For HA51R)
8. External
Output for Auto Dialer (S126 for N.C. use only).
9. External
Output for Alarm System
(S105
、
S125
、
HA52E when connect with HA52E
,
the function off tamper return is non-exist).
10. ANTI-JAMMING module for Option.
*11. Receive RF Signal have ARM
、
DISARM
、
PANIC
、
INSTANT
、
PARM
、
DELAY.
12. After Console is powered on
,
press HA51R "DISARM" key to memorize HA51R " HOUSE CODE
".
13. Adjustable-Code is adapted on Console to HA51M and HA51P.
The " House Code" must be same as the HA51R.
14.12V 1.2Ah Rechargeable Battery is necessary when use the extended siren (S105
、
S125
、
HA52E).
15.When the HA52E is extended, DC Adaptor must use 16V/600mA Spec. and the HA51 unit must
use OPTION version.
Model Number: HA51M (FCC)
1.Operating Voltage
:
12 V DC ALKALINE BATTERY
2.Standby Current
:
3uA (TYP.) , 6uA (MAX.)
3.Operating Current
:
8mA Max.
4.Frequency
:
433.92MHz
±
150KHz
5.Operating Temperature
:
-10
℃
〜
40
℃
6.Duty Cycle: < 35%
7.Antenna Type: PCB layout