background image

1/0 

1: remember(0: do not 
remember) 

 

LED on/off: 

Parameter 
Number 

Size  Range  Default 

0~2 

2: on for 5 seconds 
(0: disable, 1: Always 
on) 

Command Classes 

 

The module supports Command Classes including

… 

Command Class 

Version  Required Security 

Class 

ZWAVEPLUS_INFO 

None 

ASSOCIATION 

Highest granted 
Security Class 

MULTI_CHANNEL_ASSOCIATI
ON 

Highest granted 
Security Class 

ASSOCIATION_GRP_INFO 

Highest granted 
Security Class 

TRANSPORT_SERVICE 

None 

VERSION 

Highest granted 
Security Class 

MANUFACTURER_SPECIFIC 

Highest granted 
Security Class 

DEVICE_RESET_LOCALLY 

Highest granted 
Security Class 

INDICATOR 

Highest granted 
Security Class 

POWERLEVEL 

Highest granted 
Security Class 

SECURITY 

None 

SECURITY 2 

None 

SUPERVISION 

None 

FIRMWARE_UPDATE_MD_ 

Highest granted 
Security Class 

NOTIFICATION 

Highest granted 

Security Class 

SWITCH_ BINARY 

Highest granted 
Security Class 

CONFIGURATION 

Highest granted 
Security Class 

 
 

Indicator Command Class 

Indicator 
ID 

Property 
ID 

Value 

Description 

0x50 

0x03 

0~255 

On/Off Period   

0x50 

0x04 

0~255 

On/Off Cycle 

0x50 

0x05 

0~255 

On time within an 
On/Off period 

 

Additional Command Classes Supported 

 Power Level: For test purpose during product 

installation. 

 Binary Switch: Refer to Basic. 

 Firmware Update: For OTA function. 

 

Troubleshooting 

The table below lists the several steps involved when 
adding or removing the detector from the Z-Wave

TM

 

network. 
 

Action/ 
Status 

Description 

LED 
indication 

No node ID 

The Z-Wave

TM

 Controller does not 

allocate a node ID to the unit. 

2-second 
on, 
2-second off 

Inclusion 

1. Put the Z-Wave

TM

 Controller into 

inclusion mode. 

 

2. Press the button three times within 

1.5 seconds to put the unit into 
inclusion mode. 

Exclusion 

1. Put the Z-Wave

TM

 Controller into 

 

Reviews: