50
ENGLISH
9.2.9 VIEWING THE TEMPERATURE OR TIME FREEZING CYCLE
►
The DIS1 display shows the temperature of the
needle probe for the cycles with temperature or
the temperature of the cell probe for the cycles
with time.
►
The display DIS2 shows the time in decrease
for both the temperature cycles and the time
cycles.
For temperature cycles the decrease of the time starts only if the temperature of the needle
probe is lower than the value.
►
The TIME FREEZING
or TEMPERATURE FREEZING LED
is turned on.
►
Press the DECREASE button
to view, on DIS2, the elapsed time from the start of the
freezing phase.
►
During a temperature cycle you can view the temperature of the cell probe by pressing the
TIME
or TEMPERATURE FREEZING button
.
The visualisation remains on the displays for five seconds.
►
During a time cycle you can view the temperature of the needle probe by pressing the TEMPERATURE
button.
.
The visualisation remains on the displays for five seconds.
When the temperature of the needle probe reaches the value defined for a temperature cycle,
or the preset time expires for a time cycle, the negative blast chilling phase ends, the buzzer
sounds and the storage phase begins.
►
The buzzer can be silenced by pressing the DECREASE button.
.
►
During the storage phase, pressing the DECREASE button
allows you to view the total
duration of the freezing cycle.
You can view the temperature of the needle probe by pressing the NEEDLE PROBE button
display will remain on the displays for five seconds.
NOTE:
If the temperature of the needle probe don’t reaches the setpoint within the specified time,
the display DIS2 will flash, however, the cycle will continue until the setpoint is reached.