Setup Guide and component Identification
Section 2
SIDE VIEW
+
+
+
Burn Back
+
-
1. Wire Spool Holder Assy.
2. Polarity Buss Bar
3. Burn Back Control Timer
4. Wire Feeder Assy.
TO INSTALL WIRE:
1.
Loosen top idler tensioner, rotating counter-clockwise
2.
Flip tensioners down, releasing top drive rolls.
3.
Raise top drive rolls.
4.
Inspect the drive roll to make sure that the groove size matches the wire
diameter. Reversal of the lower roller may be necessary. To reverse the
roller, remove the thumb screw securing the drive roll. Pull the drive roll
off, and flip the drive roll over. Reassemble and tighten roller. If larger
roller is needed, contact Everlast.
5.
Thread straightened wire over grooves in lower drive roll, fully through
until it begins to start threading into the gun section. Lower upper drive
rolls onto lower drive roll, keeping wire in the groove.
6.
Raise tensioner back into place. Tighten slightly so wire will feed. Notice
markings on tensioner for future reference.
7.
Hold torch straight out as possible. Press gun trigger to feed wire until the
wire exits the end of the torch.
8.
Adjust tensioner clockwise until drive rolls will not slip when wire comes
into contact with surface and the wire will curl up on end. Remember to
keep wire away from metal that is attached to the work clamp clamp to
prevent the wire from arcing.