Program Setting
The above program time and temperature can be modified.
To adjust Heat/Cool program settings:
1.
In Heat/Cool Mode, press SET button to enter Setting Menu.
2.
Press NEXT button to display PROG.
3.
Press ENT button to enter program setting: “ON”/”OFF”.
4.
Press UP or DOWN button to select program on / program off.
5.
Make sure “On” is selected, press NEXT button to select the item
that you want to change (Weekday/Weekend, Four Zones,
Hour, Minute or Setting Temperature).
6.
Press UP or DOWN button to adjust the item.
7.
Press MODE button to return to Weekday/Weekend program
8.
Press MODE button again, to confirm the setting and return to
Setting Menu.
9.
*** Press NEXT button to return to Normal Display Mode.
Temporary Override
When Program is On, this thermostat controls the output according
to the program.
If you want to override the programmed temperature temporarily:
1.
Press UP or DOWN button to adjust Heat / Cool setting
temperature setpoint with
displayed.
2.
In Heat Mode, only Heat setting temperature can be adjusted.
3.
In Cool Mode, only Cool setting temperature can be adjusted.
4.
The Heat / Cool setting temperature will be confirmed and the
thermostat will return to Normal Display Mode, if no key is
pressed for 10 sec.
Temporary Override Mode will last until the next programmed time
(zone) begins. At that time, the Heat / Cool setting temperature will
follow the programmed setting temperature and
will
disappear. Or
can be stopped manually by pressing
MODE key.
Program Off
When Program is Off, this thermostat controls the output according
to a single setpoint like a simple setback thermostat. To set the unit
to be Program Off, follow the above “Program Setting” to select
Program Off. When this thermostat is Program Off, the Program
Mode will be disabled and the time zone icons will disappear in
Normal Display Mode.
To adjust the setpoint at Program Off:
1.
Press UP or DOWN button to adjust the Heat / Cool setting
temperature. The icon
will NOT be shown in Program
Off.
2.
In Heat Mode, only Heat setting temperature can be adjusted.
3.
In Cool Mode, only Cool setting temperature can be adjusted.
4.
*** The Heat / Cool setting temperature will be confirmed.
Fan Operation
If FAN ON is selected, fan runs continuously.
If FAN AUTO is selected, fan runs only when the Heating or Cooling
system is on. Fan will be turned off 2 minutes after the Heating /
Cooling system is off.
Fan Mode setting:
1.
Press SET button to enter Setting Menu.
2.
Press NEXT button to display FAN and press ENT button.
3.
Press UP or DOWN button to select FAN ON / FAN AUTO.
4.
Press MODE button to confirm the setting and return to Setting
Menu.
5.
*** Press NEXT button to resume to Normal display mode
Advanced Setting
Advanced Setting
contains Function Setting Selection, Temperature
Calibration and Room Temperature Display.
Function Setting Selection
1.
Press and hold SET and DOWN buttons for 2 seconds to enter
Advanced Setting Mode.
2.
The left letters represent Function Type; the right letters represent
the settings.
3.
Press UP or DOWN button to adjust the setting.
4.
*** Press NEXT button to select Function Type or to return to Normal
Display Mode at the end of Function Setting selection.
Table of the Function Setting Selection
Function Type
Description
LCD
Display
Setting
12 (default)
12hr/24hr
Selection
hr
24
°C
Temperature
Display Unit
dE
°F (default)
05 (+/- 0.5
C )
10 (+/- 1.0
C )
10 (+/- 1
F) (default)
Temperature
Control Span
SP
20 (+/- 2
F)
E (Electrical Heat) (default)
Fan Control
FC
O (Gas/Oil Heat)
S (10 seconds) (default)
Heater
Minimum-Off
Delay
dL
L (4 minutes off time)
Temperature Control Span
It controls how much the room temperature can be deviated from the
setpoint. A smaller degree will result in a more accurate control. A
larger degree will result in less on/off cycling and it usually saves more
energy.
Fan Control
It should be set according to the type of Heating system used. Select
“E” for Electric Heat, fan will be On when Heat is On. Select “O” for
Gas Heating or Oil Heating, fan will NOT be on when Heat is On.
Heater Minimum Off Delay
It should be set according to the heater type. Select “L” if compressor
is used for heating. Select “S” when a compressor is not used.
Temperature Calibration
This thermostat is calibrated at factory and calibration is
generally not required. However, in the event that a deviation is
found,
1.
In Normal Display Mode, press and hold UP and DOWN
buttons for 5 seconds to change the temperature calibration
display and the current temperature will flash,
2.
Press UP and DOWN button to calibrate the temperature. The
maximum range to be adjusted is +/- 3.0°C or +/- 6°F, in step
of 0.5°C / 1°F.
3.
***Press MODE key to confirm the
setting and return to Normal
Display Mode.
Room Temperature Display (for Checking by Technician)
1.
In Normal Display Mode, press and hold MODE and SET
buttons for 5 seconds to display the room temperature in
small display.
2.
*** Press MODE key to return to Normal Display Mode.
Replaceable Batteries
When
appears on the display, replace the batteries
promptly with 2 fresh AAA alkaline batteries. Batteries should be
installed with proper polarity. Do not mix old and new batteries.
Specification
1.
Temperature Measurement: 0 - 40
C / 32 - 99
F
2.
Accuracy:
±0.5
C / 1°F
3.
Resolution:
0.5
C /1°F
4.
Power Supply:
24Vac or 2 x AAA Alkaline
Batteries
5.
Rating:
24Vac 50/ 60Hz 1A Max
6.
Relay Contact Voltage:
24Vac Max. 50/60 Hz
7.
Relay Contact Current:
1A Max. (Inductive)
8.
Sensing Element:
NTC Thermistor (with External
Cable 36” )
9.
Heat/Cool Setting:
16 - 35
C / 60 - 95
F
10.
Operating Temperature:
0 - 50°C / 32 - 122°F
11.
Storage Temperature:
-5 - 50°C / 23 -122°F
Remarks:
*** The operation will return to Normal Display Mode if no key is
pressed for 10 sec.
Evergreen Products, LLC
www.egreenproducts.com
<Down> Key
Function
Type
<NEXT> Key
Setting
<Up> Key
Setpoint
Room
Temperature