WT060 Programmable Thermostat Heat/Cool/Off
Instruction Manual 130903
Before Installation
Turn off WT060, all electronic source and electrical devices which
will be connected before installation and maintenance.
The installer must be a trained service personnel.
Installation Location
The thermostat should be mounted on an inner wall ~5 feet above
the floor in a position where it is readily affected by changes of the
general room temperature with freely circulating air.
Prevent direct exposure to sunlight, drip or splash. Do not place the
unit at a location where air circulation is low, or where there are
great temperature changes (e.g. near door). Do not place the
thermostat near heat generating sources (e.g. radiators, hot air
vents, TV or lights).
Opening
Pull out the battery
drawer.
Then lightly press on
the spot shown
below in order to
detach the front
shell from the base.
Mounting
1.
Ensure that the
surface is level.
2.
Place the cables at
the hole near the
terminal block.
3.
Insert 2 pcs of wall
anchors into the
holes of the wall.
4.
Fasten the
thermostat with 2
pcs of long screws
through the 2
mounting holes.
Wiring
There are 7 wiring terminals at the back of the thermostat which are
labeled as “S1”, “S2”, “W”, “Y”, “G” , “C” and “Rc” .
The recommended wire range is (AWG) 14-22.
Batteries Insertion (Optional)
The batteries work as power back-up if 24Vac power supply shuts off.
Pull out the battery drawer and insert 2 fresh AAA alkaline batteries
into the drawer according to the polarity marked inside, then slide the
drawer back into place.
Operation
When the unit is powered on, all the LCD segments are ON and then
the first display screen is Normal display mode as below picture.
Button
Description
MODE
For changing the system mode:
OFF: system off
HEAT: heating only on
COOL: cooling only on.
SET
For changing the Setting Menu.
(Fan, Time, Program)
UP & DOWN
To adjust temperature setpoint (temporary
override)
LCD
Description
DEFROST
When temperature is below 5°C / 40
F, Heater
is on regardless of the setting temperature.
LO
Below 0°C / 32°F, heating will be activated in
Heat Mode.
HI
Above 40°C/ 99°F. cooling will be activated in
Cool Mode.
- -
External wired temperature sensor is
disconnected or short.
Time Setting
1.
Press SET button to enter Setting Menu.
2.
Press NEXT button to display CLOC and press ENT button.
3.
Press NEXT button to select the item that you want to
change (Day of week, Hour or Minute).
4.
Press UP or DOWN button to adjust the item.
5.
Press MODE button to confirm the setting and return to
Setting Menu.
6.
*** Press NEXT button to return to Normal Display Mode.
Temperature Control
This product can work as a simple setback thermostat or a
programmable thermostat. By default, this product is configured
as a programmable thermostat (Program On).
Program On
When program is on, this thermostat will control the output
according to the programmed time and temperature. The
Default Program Settings are as below:
Heat Mode:
MON~FRI
SAT
SUN
Time
Zone
Time
°F/°C
Time
°F/°C
Time
°F/°C
WAKE
6AM
70/21
6AM
70/21
6AM
70/21
OUT
8AM
61/16
8AM
61/16
8AM
61/16
BACK
6PM
70/21
6PM
70/21
6PM
70/21
SLEEP
10PM
61/16
11PM
61/16
11PM
61/16
Cool Mode:
MON~FRI
SAT
SUN
Time
Zone
Time
°F/°C
Time
°F/°C
Time
°F/°C
WAKE
6AM
75/24
6AM
75/24
6AM
75/24
OUT
8AM
85/29.5
8AM
85/29.5
8AM
85/29.5
BACK
6PM
75/24
6PM
75/24
6PM
75/24
SLEEP
10PM
85/29.5
11PM
85/29.5
11PM
85/29.5
Symbols
Terminals
S1
S2
External wired temperature sensor 36”
W
Heat relay (1A Max.)
Y
Cool contractor (1A Max.)
G
Fan relay (1A Max.)
C
Common wire for power
Rc
Power for cooling (24Vac)
UP
Button
DOWN
Button
MODE
Button
SET
Button
Temperature
Setpoint
Time
S1
S2
W
Y
G
C
Rc
24Vac
24Vac
COM
Sensor
Heat relay
Cool relay
Fan relay