background image

 

 Document #DS20-007024 

v3.8 rev 2/15/06 

O p e r a t i o n   a n d   M a i n t e n a n c e  

No routine maintenance is required. However it is 
advisable to perform periodic inspection of the 
modules for damage to glass, backskin, or frame. 
Check electrical connections for loose connections and 
corrosion. 

PV modules can operate effectively without ever being 
washed, although removal of dirt from the front glass 
can increase output. The glass can be washed with a 
wet sponge or cloth. Wear rubber gloves for electrical 
insulation. 

 
 
 
  Temperature Effects 

I-V Characteristics* 

Pp – 

0.49%/°C 

Vp – 

0.53%/°C 

Ip + 

0.049%/°C 

Voc – 

0.41%/°C 

Isc + 

0.088%/°C 

NOCT 44°C 

 

 

E l e c t r i c a l   R a t i n g s *  

 

 EC-94-G

 

EC-102-G EC-110-G EC-115-G  

EC-120-G

Pp 94 

102 

110 

115 

120 

Vp 16.7 

16.7 

17.0 

17.1 

17.6 

Ip 5.63 

6.11 

6.47 

6.73 

6.82 

Voc 

21.3 21.3 21.3 21.3 21.5 

Isc 6.86 

7.32 

7.48 

7.62 

7.68 

Cells 

72 72 72 72 72 

Bypass Diode 

Type AR2510, 1000V, 25 A  

Maximum Series Fuse 

15A 

UL Rated System Voltage 

600V 

TUV Rated System Voltage 

800V 

*At STC (Standard Test Conditions): 1000 W/m

2

, 25° C cell temperature, AM 1.5 spectrum. Minimum Specified Power Rating is 90% 

of above power rating. All modules are factory-inspected to produce at least 98% of above power rating; other specifications are 

+/-10%. Specifications subject to change without notice. 25 year limited power warranty. Complete warranty available on request. 

Note: This document may be provided in multiple languages. 

If there is a conflict among versions, the English language version dominates. 

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

0

5

10

15

20

25

Voltage (V)

Current

 (A)

EC-94

EC-102

EC-120

EC-115

EC-110