N.O.: Normal Open contact.
N.C.: Normal Closed contact.
Display Switch:
Select which channel to be displayed when alarm is triggered. Available options are CH1 and
CH2.
Alarm Output:
This will transmit a signal through the alarm output. It can be set to either “
NONE
” (not active) or
“
1
” (selects alarm relay to be active).
Output Type:
Output action when alarm is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will remain active until the user presses the
“Enter”
key or resets the alarm remotely.
Transparent: Alarm output remains as long as the alarm input is active.
Trans+Timeout: Alarm output continues until event ends, then continues for the set time duration.
Timeout Duration:
Time duration selectable from 1 to 150 seconds.
Pre-alarm Record:
Check box to start copying recorded video to the hard disk from 5 seconds before the alarm
event. (Pre-alarm recording rate will follow the “
Normal
” frame rate setting)
Email:
Check box to enable email notification when an alarm occurs. Email operation requires that valid email
settings have been entered in the Network Setting/Email setup screen. (See Section 4.7.4 Email for more
information.)
Network Alarm:
Check this box to send out a network alarm to a client PC when motion occurs. (This feature
requires PowerCon software on the client PC and proper settings for the Alarm Server in the Network Setup
menu; see Section 4.7.6 Alarm Server for more information.)
Click
button to return to the previous level of menu.