POWER CONNECTION
WARNING
• Follow the connection instructions shown in the
“s
pecIFIcatIons
and
technIcaL
data
”
paragraph
”
.
• The motor pump power supply must comply with the data indicated on the plate (4): in particular, the power
voltage must not deviate by ± 10 % and the power source must be of a suitable power.
• If the power cable is too short, an extension cable may be used provided it is not longer than 5 m/16 ft and
that the cable section is at least 2.5 mm
2
<AWG 14> (EF 7000 - 12V 4 mm
2
<AWG 12>).
• Ensure polarity in the connections (see also
Figure 5
):
red cable
→
positive (+);
black cable
→
negative (-).
• When connecting the motor pump to a battery, proceed as follows:
- if present, disconnect the earth cable;
- connect the red cable to the positive pole (+) of the battery;
- connect the black cable to the negative pole (-) of the battery;
- if present, reconnect the earth cable.
• When disconnecting the motor pump from a battery, proceed as follows:
- if present, disconnect the earth cable;
- disconnect the black cable from the negative pole (-) of the battery
- disconnect the red cable from the positive pole (+) of the battery;
- if present, reconnect the earth cable.
HYDRAULIC CONNECTION
WARNING
• Follow the connection instructions shown in the
“s
pecIFIcatIons
and
technIcaL
data
”
paragraph.
• The suction pipes must have a nominal pressure equal to 5 bar (73 psi).
• The delivery pipes must have a nominal pressure not below max. motor pump pressure.
• Do not tighten the suction and delivery fittings to a torque of more than 5 Nm (45 lbf in).
• All the pipes must be firmly fastened with clamps to the respective fittings.
For the hydraulic suction and delivery connections, refer to the following table and to
Fig. 6
, which
represents a generic diagram of a possible machine in which the motor pump is integrated.
a. Tank
b. Suction filter
c. Suction circuit
d. Motor pump
e. Delivery circuit
f. Spray lance (example of accessory)
The connections to suction and delivery of the motor pump must be done according to the model
considering the couplings and minimum internal pipe diameters illustrated in the following table:
Model
Coupling
Minimum internal pipe diameter
EF 1200
hose holder Ø 10 mm (3/8")
10 mm (3/8")
EF 2200
3/8 NPT female
13 mm (1/2")
EF 3000
1/2 NPT female
EF 4000
EF 5500
19 mm (3/4”)
EF 7000
EN
Summary of Contents for EF 1200
Page 2: ......
Page 4: ...1 1 4 3 2 1 2 EF 1200 ...
Page 5: ...3 2 1 4 2 3 1 2 4 3 EF 2200 EF 3000 EF 4000 EF 5500 ...
Page 6: ...4 5 5 6 1 4 2 3 EF 7000 ...
Page 7: ...6 7 d a e f c b EF 1200 100 3 3 95 80 8 3 18 78 1 3 08 184 7 24 57 2 2 25 ...
Page 8: ...8 EF 7000 EF 3000 EF 4000 EF 5500 EF 2200 9 19 234 2 50 64 5 34 136 5 28 134 4 25 108 ...