EverExceed Titan Series User Manual Download Page 12

12.Technical Parameters

MPPT solar controller

m

odes:

Titan series

15A

20A

25A

30A

40A

Charge Mode

MPPT 

(

maximum  power pointtracking)

Method

Three stages: constant current (MPPT), constant 

voltage, floating charge.

48Vsystem

DC36V

~

DC60V

System

DC12V

/

24V/48V

Automatic

rec

ognition

System voltage

12Vsystem

DC9V

~

DC15V

24Vsystem

DC18V

~

DC30V

Soft StartTime   

12V/24V

/

48Vsystem

3S

Dynamic Response

 

R

ecovery

Time

12V/24V

/

48Vsystem

500us

MPPT efficiency

12V/24V

/

48Vsystem

99%

INPUTCHARACTERISTICS

MPPT working 

voltage range

12Vsystem

DC14V

~

DC100V

24Vsystem

DC30V

~

DC100V

48Vsystem

DC60V

~

DC100V

Low

inputv

oltage 

protection point

12Vsystem

DC14V

24Vsystem

DC30V

48Vsystem

DC60V

Low

inputv

oltage 

Recovery point

12Vsystem

DC18V

24Vsystem

DC34V

48Vsystem

DC65V

High input

v

oltage 

protection point

12V/24V

/

48Vsystem

DC110V

High input

v

oltage 

recovery point

12V/24V

/

48Vsystem

DC100V

Maximum PV power

12Vsystem

213W

284W

355W

426W

568W

24Vsystem

426W

568W

710W

852W 1136W

48Vsystem

852W

1136W 1420W 1704W 2272W

CHARGE

CHRE

CTRESTICS

Selectable Battery 

Types

(Def

ault

Gelbat

tery)

12V/24V

/

48Vsystem

Sealed lead acid,

vented,

Gel,

N

iCd 

battery

(

  

O

ther

t

ypes

of

the batteries

also

c

an be defined

)

ConstantVoltage

12V/24V/48Vsystem

Pleasecheckthechargevoltage

accordingtothe

battery

type

form

.

12V/24V/48Vsystem

FloatingCharge

Voltage

Rated Output Current

12V/24V

/

48Vsystem

15A

20A

25A

30A

40A

12V/24V

/

48Vsystem

20A

25A

30A

35A

45A

Current-limiting 

Protection

 

 

 

Temperature Factor

12V/24V

/

48Vsystem

±

0.02%/

Temperature 

Compensation

12V/24V

/

48Vsystem

14

.

2

V

-

(The highest temperature 

-25

)

*0

.

3

Output

Ripples(speak)

12V/24V/48Vsystem

200mV

Output

Voltage 

Stability Precision

12V/24V/48Vsystem

±1.5%

OutputDischargeCharacteristics

OutputDischargeCharacteristics

PC(communicationport)

LowvoltageoutputProtectionpoint

Default10.5V;Recovery11V;

Itcanbeadjustable.

RatedoutputCurrent

30A

Theoutputcontrol

Onmode, Offmode, PVvoltagecontrolmode

Outputcontrolsetmode

ControllerbuttonorPCsoftware

Display

LEDdigitaltubedisplay

Batteryvoltage, Chargecurrent

LEDlightdisplay

Chargingindicatorlight, LOADindicatorlight

PC(communicationport)

RS232

Protection

Lowinputvoltageprotection

Checktheinputcharacteristics

Highinputvoltageprotection

Checktheinputcharacteristics

Chargeoverpowerprotection

yes

Dischargelowvoltageprotection

yes

Dischargehighcurrentprotection

yes

Temperature protection

yes

OtherParameters

Noise

Thermalheat-dissipatingmethod

Components

Certification

40dB

Fancooling

ImportedmaterialWithEUstandards.

CE\FCC\RoHS

Physical

MeasurementD

 x W x 

H(mm)

 

373*193*72.5

 

N.G(kg)

3.6

MechanicalProtection

IP21

Environment

Humidity

0~90%RH 

(noc

ondense)

Altitude

0~3000m

Operating temperature

-

20

℃ 

~+

50

℃ 

Storage temperature

-

40

℃ 

~+

75

℃ 

Atmospheric

P

ressure

70~106kPa

 

21

22

www.everexceed.com

www.everexceed.com

Summary of Contents for Titan Series

Page 1: ...Titan Solar Charger Controller User Manual Titan Series www everexceed com ...

Page 2: ...e controller Please take good care of this manual for future reference whenever necessary The If you violate the operation rules it would endanger personal If you violate the operation rules it would endanger personal Contents 1 Notes on This Manual 2 Safety Instructions 3 Unpacking 4 Assembly 5 MPPT controller Connection 6 Meaning of LED LCD and function key 7 Parameter Setting 8 MPPT and PC Conn...

Page 3: ... skilled person The Controller is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction 2 1General Safety Instructions Warning Caution Surface may be extremely hot and may cause burns Do not touch the enclosure of the charge controller during operation If possible keep in...

Page 4: ...he solar charge controller please read all instructions and cautionary markings on the solar charge controller and all corresponding sections of this guide Please use components and parts recommended or sold by EverExceed Otherwise may result in a risk of fire electric shock or injury to person To avoid a risk of fire and electric shock make sure that existing wiring is in good condition and that ...

Page 5: ... 4 Assembly 4 1 Operator technical personnel 4 2 Selecting the Mounting Location Danger Danger to life due to fire or explosion The charge controller enclosure can become hot during operation Do not mount the charge controller on flammable construction material Do not mount the charge controller near highly flammable materials Do not mount the charge controller in potentially explosive areas Do no...

Page 6: ...y using a disconnection unit and secure it against accidental reactivation Disconnect the circuit breaker and ensure that it cannot be reconnected Ensure that no voltage is present in the system Warning Risk of injury due to electric shock If all cables with different voltages are routed in parallel damaged cable insulations may lead to a short circuit Route all cables separately Warning Over volt...

Page 7: ...e output voltage range based on the type of battery bank system Like the battery bank voltage is 48V DC output voltage range will be the range of 48V battery bank working voltage 1 How to turn DC output turn on off Please find the DC output control through MPPT or Monitoring software have 6 way to control it ON Mode OFF Mode Time Control Mode PV Volt Ctrl PV Time Ctrl Details please check the Sett...

Page 8: ... breaker make sure PV and controller disconnect Warning When the controller is charging for battery please do not turn off the breaker with battery before PV input have not turn off Or the machine will have unrecoverable fault and this will not in the warranty 6 Meaning of LED LCD and function key 6 1Panel Description Meaning of LED and function key LEDs and buttons Instruction CHARGE Blue Control...

Page 9: ...mode Press ENTER2 button for 3 seconds change on mode or off mode the LOAD indicator light changes at the same time The LOAD indicator light DC output on The LOAD indicator dark DC output off Number Types 00 User defined by PC software 01 Gel 02 NiCd 03 Sealed 04 Vented 8 MPPT and PC Connection Overview Get into main interfaceas following Com Setting Com Get into set the connection of Solar Eagle ...

Page 10: ...roller to battery will automatically start Step 3 Connected PC and controller with RS232 and PC will notice the communication at this time the PC will chose COM1 Step 4 Open the software as administrator WIN 7 of 8 then press to choose COM communication and enter It will automatically connect Step 5 A The software is now ready to be used 2 Customer do not have PC connector If customer do not have ...

Page 11: ...if deemed necessary 10 Storage and waste disposal Store the charge controller in a dry place with ambient temperatures between 40 C and 75 C Disposal Dispose of the solar charge controller at the end of its service life in accordance with the disposal regulations for electronic waste which apply at the installation site at that time 11 Recovery Processing and Warranty Recovery Processing When the ...

Page 12: ... Rated Output Current 12V 24V 48Vsystem 15A 20A 25A 30A 40A 12V 24V 48Vsystem 20A 25A 30A 35A 45A Current limiting Protection Temperature Factor 12V 24V 48Vsystem 0 02 Temperature Compensation 12V 24V 48Vsystem 14 2V The highest temperature 25 0 3 Output Ripples speak 12V 24V 48Vsystem 200mV Output Voltage Stability Precision 12V 24V 48Vsystem 1 5 Output Discharge Characteristics Output Discharge ...