Troubleshooting

 

 

 

Problem 

Possible Cause 

Corrective Action 

Motor runs but no water 
is discharged 

Be sure pump is actually running, not 
just humming 

See section below called “Motor hums-pump not running” 

Discharge hose or pipe is blocked or 
too restrictive 

Check hose/pipe for blockages. Check manual for maximum 
lengths of pipe/hose that pump can handle. Do not use a hose/pipe 
that is narrower than the discharge of the pump itself. 

Discharge hose/pipe goes up too high 

Every pump has a maximum “head” capability, which is the 
highest it can lift water. Do not route discharge hose/pipe higher 
than the rating on Pg. 2. 

Impeller or other internal parts are 
worn, damaged, or clogged 

Inspect the impeller and volute for wear or breakage. Repair or 
rebuild as needed. Check for clogs in the impeller screen and in 
the outlet riser (part that extends from volute to outlet). 

The pump is non-submersible, make 
sure it is primed 

Non-submersible utility pumps need to be primed with water 
before use. Follow directions in the owners’ manual regarding 
priming. 

Motor just hums – pump 
not running 

Impeller is stuck or jammed with 
debris 

Inspect the impeller area for any debris that may have 
entered. Remove as needed. 
Make sure impeller rotates freely. 

Motor is locked up 

Check cooling shroud and/or vents in motor case for foreign 
objects or for shifting in the case. Remove objects and/or 
straighten the motor shroud. 

Motor has failed 

If all items above check out OK, the motor has failed. Replace 
pump. 

Motor does not run or 
make any noise at all 

Pump is not getting any power 

Reconnect the cord set. 
The house fuse is blown, replace with a fuse of proper size. 
Recharge the battery or replace with a new battery. 

Brushes worn out 

Check and replace brushes. 

Internal connection or motor has failed 

If all items above check out OK, the motor has failed. Replace 
pump. 

The liquid temperatures below 30 
degrees F or above 77 degrees F.  

Do not operate pump in temperatures as indicated.  

Pump runs and moves 
water but the quantity of 
water is less than it 
should be 

Discharge hose is restrictive 

If you are using a hose that is narrower than the pump discharge, 
or a long hose, the pump will not be able to discharge water at the 
rate for which it was designed. Use a shorter, fatter hose. 
Check hose for coils or kinks. Lay hose out straight for best 
performance 

Suction hose has an air leak 

On pumps that use a hose for the suction, it is important that the 
hose have air-tight connections. If air can be pulled in through a 
hose connection, the pump’s performance will be diminished. 

Debris partially blocking intake area 

Remove debris and ensure intake area is clear for optimum 
performance 

Discharge elevation too high 

The higher the discharge hose goes, the less water the pump can 
move. For improved performance the hose should go up too high. 

Suction hose has collapsed and won’t 
stay open 

Suction hoses should be reinforced so that they can maintain their 
shape under suction conditions. Replace hose with reinforced, 
suction rated type. 

Impeller or other internal parts are 
worn or damaged 

Inspect the impeller, diffuser, and other internal parts for wear and 
damage. Repair as needed 

 

Summary of Contents for ZE00804

Page 1: ...ed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Everbilt SKU 1001093988 Model ZE00804 USE AND CARE GUIDE Non S...

Page 2: ...he power to the pump before servicing DANGER Do not touch the motor housing during operation The motor is designed to operate at high temperatures Do not disassemble the motor housing DANGER Do not ha...

Page 3: ...in materials or workmanship the manufacturer s only obligation and your exclusive remedy is the repair or replacement of the product at the manufacturer s discretion provided that the product has not...

Page 4: ...ty PACKAGE CONTENTS Part Description A Pump B Suction strainer C Suction hose D Replacement Impeller DC MOTORS DC motors must be connected to a fully charged automotive tractor or marine type battery...

Page 5: ...airtight An air leak can cause the pump A to run dry 3 Attaching the suction hose to the pump inlet 4 Attaching the discharge hose to the pump outlet Thread the other end of the suction hose C to the...

Page 6: ...The pump is designed for use with a 12 Volt DC battery Operation requires a minimum 12 Volt power supply All wiring must be 12 gauge stranded copper wire that is A Water resistant B Oil resistant C F...

Page 7: ...TE Do not disassemble the motor housing of the pump This motor has NO repairable internal parts and disassembling may cause a dangerous electrical wiring issue Fuse Replacement 1 Gently press the two...

Page 8: ...e motor has failed Replace pump Motor does not run or make any noise at all Pump is not getting any power Reconnect the cord set The house fuse is blown replace with a fuse of proper size Recharge the...

Page 9: ...e water the internal parts of the pump will wear at an accelerated rate Some liquid other than water is being pumped Many liquids have very little lubricating qualities They will not lubricate the imp...

Page 10: ...Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 6 p m EST Monday Friday 1 844 241 5521 HOMEDEPOT COM...

Reviews: