Troubleshooting

Problem

Solution

The fan will not turn on.

 

Ensure that there is a proper electrical connection.

 

Check the breaker in the main fuse panel.

 

Ensure that the belt is intact and/or installed (CX30BD-2SPDEVB belt-drive unit only).

The fan will not turn off.

 

Ensure that there is a proper electrical connection.

There is a loud noise coming 
from the unit.

 

Ensure that there are no obstructions or debris caught in the housing.

 

Ensure that the unit is securely fastened to its mounting surface.

 

Try to identify whether the noise is coming from the motor. If it is, it is possibly a bearing issue. 

 

Check for any loose screws or hardware.

 

Open one or more additional windows to ensure adequate air flow. 

 

If the unit is too noisy in general, install the additional frame between the fan and mounting frame. 

 

Large fans make noise while operating. Moving the fan further into the attic will reduce the apparent 
noise. Make sure you still have 36 in. of clearance to the roof. 

 

Make sure all screws and bolts are tightened. 

 

Ensure that there is enough clearance above the unit, minimum of 36 in. from fan blades to roof. 

 

Verify the exhaust Net Free Air (NFA). Inadequate NFA will result in the unit working harder and 
making more noise.

The motor stops after 10 to 20 
minutes.

 

Tight belt tension can cause the unit to overheat. 

 

There is insufficient intake or exhaust of NFA. Open more doors and windows or increase the amount 
of ventilation in the attic. 

 

Check the bearing assembly for resistance on belt-driven models to ensure there are no rough spots. 

There is not enough air flow. 

 

Verify that NFA intake and exhaust requirements are being met. Lack of airflow can be the result of 
lack of fresh air and lack of ventilation to expel the air. Try channeling the air by opening only doors 
and windows in a certain area to funnel the wind flow. 

The shutter is hitting the fan.

 

Check to make sure there is enough space between the louvers and the fan. There should be around 6 
to 7-1/2 in. between the fan blade and the vent. 

The fan does not start on low 
speed.

 

Verify that the fan will start on high speed. Switch to low speed from the high setting. For additional 
troubleshooting, please contact our customer support team. 

Summary of Contents for 1005 588 347

Page 1: ...e to see our full line of products available for your home improvement needs Thank you for choosing Everbilt USE AND CARE GUIDE WHOLE HOUSE FANS Questions problems missing parts Before returning to th...

Page 2: ...ineers ASHRAE and the local code authorities 3 When cutting or drilling into the wall or ceiling do not damage the electrical wiring or other hidden utilities 4 Use this unit only in the manner intend...

Page 3: ...turn to you any part of component not covered by this warranty including parts of components damaged by you The company reserves the right to demand and receive written evidence of the date of purchas...

Page 4: ...ription A CX30BD 2SPDEVB fan C ON OFF switch E Switch plate cover B Shutter assembly D HIGH LOW switch F Wood screws PACKAGE CONTENTS CX242DDWTEVB A F C D E B Part Description Part Description Part De...

Page 5: ...un lengthwise in 24 in and 30 in shutters The center vein is stationary to allow for no cut joist installation When measuring vents for NFA remember that louvers and screens cut down considerably on t...

Page 6: ...lar saw Measure the depth of the drywall and adjust the saw so you only cut the drywall and avoid the joists Carefully remove the drywall from the opening NOTE Make sure the exposed joist is centered...

Page 7: ...0BD 2SPDEVB BELT DRIVE Remove the hardware and remount the motor on the top side of the struts Position the fan belt on the pulleys and adjust it to fit snugly with about 1 2 in deflection DO NOT OVER...

Page 8: ...f switch 1 Connect the bottom right terminal of the On Off switch 2 to the bottom right terminal of the High Low switch 3 using a jumper wire Connect the high speed motor lead BLACK to the top right t...

Page 9: ...e to mark the other three sides of the shutter opening using rough opening dimensions in the table on page 5 From the ceiling side drill two more 1 4 in holes at the remaining corners 2 Cutting the sh...

Page 10: ...evious step 5 Installing the facing Use 2 X 6 boards to create a square with the inside dimensions being the same distance as the shortest dimension of the shutter rough opening i e 26 in for a 24 in...

Page 11: ...X30BD 2SPDEVB BELT DRIVE Remove the hardware and remount the motor on the top side of the struts Position the fan belt on the pulleys and adjust it to fit snugly with about 1 2 in deflection DO NOT OV...

Page 12: ...On Off switch 1 Connect the bottom right terminal of the On Off switch 2 to the bottom right terminal of the High Low switch 3 using a jumper wire Connect the high speed motor lead BLACK to the top ri...

Page 13: ...be sure that the flue damper is closed to prevent chimney soot from being drawn into the house by the fan DO NOT operate the fan when a fire is burning in the fireplace Maintenance WARNING Disconnect...

Page 14: ...are tightened Ensure that there is enough clearance above the unit minimum of 36 in from fan blades to roof Verify the exhaust Net Free Air NFA Inadequate NFA will result in the unit working harder an...

Page 15: ......

Page 16: ...ons problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 877 527 0313 HOMEDEPOT COM Retain this manual for futur...

Reviews: