Operating the pump 
 

□  Plug the pump (A) into a properly grounded outlet. 

o

 

The pump (A) is equipped with a Ground Fault Circuit Interrupter (GFCI) plug. If the pump is not running 
when it should be, check this plug to ensure it has not tripped.  If it has tripped, press the button on the 
plug to reset. If the pump continuously trips, try plugging the pump into a different outlet. 

o

 

If extension cords are used, make sure the extension cord ends cannot get wet.  The GFCI plug will not 
protect against shock hazards that occur in the extension cord. 

□  When there is at least 2-1/4 in. of water around the pump, the float switch will be raised, turning the pump on. 
□  When water is pumped down to approximately 11/16 in., the pump will run for an additional 30-60 and then shut 

off. 

□  The pump will turn on again when water rises to 2-1/4 in. 

 

 

WARNING

: Do not allow the plug to fall in the water 

and do not stand in the water or on a damp surface 
while the pump is plugged in. Do not handle the 
plugged-in pump with wet hands.

 

 

  

Operation

 

 

 

 

NOTE

: The float switch is located in the cage on 

the side of the pump. Keep this cage clean so the 
float switch can operate properly.

 

Summary of Contents for 1004181632

Page 1: ...designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Everbilt Item 1004181632 Model EBAU25 PCP USE AND CARE GUIDE 1 4 HP SUBMERSIBLE POOL COVER PUMP Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 5 p m EST Monday Friday 1 844 251 7446 HOMEDEPOT COM ...

Page 2: ...ircuit Interruptor GFCI To reduce the risk of electrical shock be certain that it is connected only to a properly grounded receptacle DANGER Do not handle the pump with wet hands or when standing on a wet or damp surface or standing in water before disconnecting the power DANGER Never touch any electrical device including this pump when it is touching water in water or even in a moist environment ...

Page 3: ...power cord Keep the pump intake clear CAUTION Periodically inspect the pump and system components to ensure the pump intake is free of mud sand and debris Disconnect the pump from the power supply before inspecting CAUTION Know the pump and its applications limitations and potential hazards CAUTION Follow all electrical and safety codes particularly the National Electrical Code NEC and in the work...

Page 4: ...tion or exclusion may not apply to you This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state Contact the Customer Service Team at 1 844 251 7446 or visit HOMEDEPOT COM Pre installation APPLICATION This submersible utility pump is designed for use on swimming pool covers Its automatic design allows the pump to be left plugged in with...

Page 5: ...ny debris that may collect in the base A clear path for the water will allow the pump to perform its best Attach the garden hose adapter C to the pump A discharge NOTE For greater flow rate use a 1 1 4 in flexible discharge hose and keep hose lengths as short as possible 50 ft or less Narrow and long discharge hoses restrict the flow A 1 1 4 in female threaded coupler may need to be purchased sepa...

Page 6: ...eaks WARNING Secure the discharge hose before plugging in the pump An unsecured discharge hose may whip possibly causing personal injury and or property damage Place the pump A on the pool cover Using a pole broom or rake push the pump A to the desired location on the pool cover NOTE Depending on your pool cover the pump may tip In order for the float switch to operate properly try to place the pu...

Page 7: ...cannot get wet The GFCI plug will not protect against shock hazards that occur in the extension cord When there is at least 2 1 4 in of water around the pump the float switch will be raised turning the pump on When water is pumped down to approximately 11 16 in the pump will run for an additional 30 60 and then shut off The pump will turn on again when water rises to 2 1 4 in WARNING Do not allow ...

Page 8: ...rom the pump Remove the screws and screen from the bottom of the pump Remove the screws volute and seal gasket from the pump Clean the debris from the impeller and pool cover base Reassemble If debris is preventing the float switch from operating properly remove any debris from the float switch cage on the side of the pump The bottom portion of this cage can be removed for further cleaning Contact...

Page 9: ...p directly into the power source The impeller is broken Call 1 844 251 7446 for a replacement The motor does not run or is humming The pump not running The water is not high enough to activate the float switch Water must be at least 1 1 2 in high to activate the float switch Place pump in an area with more water to activate the float switch The float switch is blocked by debris Clean out the float...

Page 10: ...Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 5 p m EST Monday Friday 1 844 251 7446 HOMEDEPOT COM Retain this manual for future use ...