PRECAUTIONS 

1.

 

This document serves only as an installation guide. Refer to 
your state and/or local plumbing, radon mitigation, or onsite 
wastewater treatment and disposal regulations for details 
pertaining to your systems design, installation and 
maintenance requirements. 

2.

 

Keep this instruction manual in a safe place for future 

reference. 
 

 

DANGER: 

Do not pump flammable or explosive liquids 

such as oil, gasoline, kerosene, ethanol, etc. Do not use in 

the presence of flammable or explosive vapors. Using this 
pump with or near flammable liquids can cause an 

explosion or fire, resulting in property damage, serious 
personal injury, and/or death. 

 

 

DANGER: 

ALWAYS disconnect the power to the pump 

before servicing. 

 

 

DANGER: 

Do not touch the pump motor housing during 

operation. The motor is designed to operate at high 

temperatures. Do not disassemble the motor housing. 

 
 
 

 
 
 

 

DANGER: 

Do not handle the pump or pump motor with 

wet hands or when standing on a wet or damp surface, or in 

water. lf basement floor is wet, do not walk on wet area 
until all power is turned off. If shut-off box is in basement, 

call the electric company to shut off service to the house, or 
call your local fire department for instructions. Remove 

pump and repair or replace. Failure to follow this warning 
can result in fatal electrical shock 

 

 

WARNING: 

Secure the discharge line before starting the 

pump. An unsecured discharge line will whip, possibly 

causing personal injury, and/or property damage.

 

 

 

WARNING: 

Release all pressure and drain all water from 

the system before servicing any component. 

 

 

WARNING: 

Wear safety goggles at all times when 

working with pumps. 

 

 

CAUTION: 

Know the pump and its applications, 

limitations, and potential hazards. 

 

Warranty 

 

The manufacturer warrants to the original consumer purchaser of the basin cover that it will be free from defects in material and 
workmanship for the Warranty Period of 12 months from date of purchase. The date of purchase shall be determined by the original dated 
sales receipt noting the model number of the cover. The original sales receipt must accompany the returned cover. If the cover fails during 
the warranty period, return the cover to The Home Depot along with the receipt. 

The manufacturer shall not be liable under this Warranty for any product that, in our sole judgment, has been subject to negligence, 
misapplication, improper installation, or improper maintenance. Also, the manufacturer shall not be liable under this Warranty if the product 
has been disassembled, modified, abused or tampered with. 

The manufacturer shall not be liable for any consequential, incidental, or contingent damages whatsoever. The manufacturer recommends 
using a professional plumber or radon mitigation contractor for all installation and repair, and periodic inspection. The manufacturer makes 
no warranty regarding the suitability of a product for a particular installation. 

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of the implied 
warranty, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have 
other rights which may vary from state to state.  

Contact the Customer Service Team at 1-877-297-6069 or visit www.HomeDepot.com.

Summary of Contents for 1002162762

Page 1: ...hance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Everbilt Item 1002162762 Model THD1085 USE AND CARE GUIDE RADON MITIGA...

Page 2: ...ressure and drain all water from the system before servicing any component WARNING Wear safety goggles at all times when working with pumps CAUTION Know the pump and its applications limitations and p...

Page 3: ...ement or garage floor to remove the existing sump or sewage basin Simply remove the old cover and install the Everbilt Radon Mitigation Basin Cover over the opening to create a new sealed system The E...

Page 4: ...r bolts PVC primer PVC cement Safety goggles Hand hacksaw or PVC cutter Silicone caulk and caulk gun MATERIALS REQUIRED NOT INCLUDED PVC pipe PVC fittings PRODUCT DESCRIPTION The cover A and B is pre...

Page 5: ...sembled to lid D 1 K 1 5 in Reducer plate Preassembled to lid D 1 L 1 5 in Discharge O ring Preassembled to lid D 1 M 1 5 in Plastic discharge flange Preassembled to lid D 1 N 1 4 20 x 1 HHC SS Preass...

Page 6: ...osition on the floor Ensure the lid s D discharge opening 1 is aligned with the sump s discharge pipe and the lid bolts Q are aligned with the cover s A threaded nuts B preassembled Mark the concrete...

Page 7: ...e lid D on the cover A Apply a bead of silicone caulk to the underside of the discharge flange assembly K M Install the discharge flange assembly over the pump discharge pipe sealing the bottom plate...

Page 8: ...r the hub installation For maximum effectiveness apply a bead of silicone caulk to all cover flange and grommet sealing surfaces Hole Saw Guide For Pipe Use Hub Hole Saw 1 in E100H 1 3 4 in 1 1 4 in E...

Page 9: ...s problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 7 p m EST Monday Friday and Saturday 9 a m 6 p m EST 1 877 297 6069 HOMEDEPOT COM Retain this manual for fut...

Reviews: