background image

www.event-lighting.com.au 

 

 

Lux Chart 

 

 

Dimensions 

 

 

 

Summary of Contents for WIP1320

Page 1: ...right to revise the manual at any time Information and specifications within this manual are subject to change without notice Event Lighting assumes no liability or responsibility for any errors or omissions Please consult Event Lighting for any clarification or information regarding this item www event lighting com au Ver 1 0 ...

Page 2: ...www event lighting com au 1 CONTENTS Safety Instructions Product Installation Diagrams Control Board Operation DMX chart Technical specifications Warranty ...

Page 3: ...ater or humidity may affect it Do not operate this device if the housing lenses or cables appear damaged Do not connect this device to a dimmer or rheostat ONLY connect this device to a grounded and protected circuit ONLY use the hanging bracket to carry this device In case of a serious operating problem stop using immediately The maximum ambient temperature is 104 F 40 C Do not operate this devic...

Page 4: ...www event lighting com au 3 Lux Chart Dimensions ...

Page 5: ... Slave selection function Back L on Display background light always stays on 60s Display background light turns off after 60s 120s Display background light turns off after 120s 300s Display background light turns off after 300s Temp Temp1 XXº Display current temperature on LED panel Temp2 XXº Display current temperature on chassis Info Test 1 Test mode without strobe Test 2 Test mode with strobe R...

Page 6: ...e Up and Down button to select strobe speed from 000 to 255 press Enter to save new setting Master Slave Mode Set the master fixture to auto or manual modes Enter Master mode use Up and Down button to select Yes and then select slave press Enter to set fixture to slave mode Use DMX cable to link master and slave fixture together DMX Data When there is a flashing the fixture is not receiving any DM...

Page 7: ...cro 13 channels Mode Channel Value Function 1 000 255 Dimmer 0 to 100 2 000 255 Red 0 to 100 3 000 255 Green 0 to 100 4 000 255 Blue 0 to 100 5 000 255 White 0 to 100 6 000 255 Intensity of strobe from short to long 7 000 255 Strobe with effect 8 000 255 Speed of effect from low to fast 9 000 255 Macro 10 000 255 Red at background 0 to 100 11 000 255 Green at background 0 to 100 12 000 255 Blue at...

Page 8: ...ck 2 green 8 000 255 Block 2 blue 9 000 255 Block 2 white 10 000 255 Block 3 red 11 000 255 Block 3 green 12 000 255 Block 3 blue 13 000 255 Block 3 white 14 000 255 Block 4 red 15 000 255 Block 4 green 16 000 255 Block 4 blue 17 000 255 Block 4 white 18 000 255 Block 5 red 19 000 255 Block 5 green 20 000 255 Block 5 blue 21 000 255 Block 5 white 22 000 255 Block 6 red 23 000 255 Block 6 green 24 ...

Page 9: ...nal Modes Manual Auto Program Master Slave DMX Modes Section Control Yes Display 4 button LCD Display Control Panel DMX Protocol DMX512 DMX Channel Mode 4 5 7 13 15 31 DMX Interface Seetronic 3 Pin Outdoor in out DMX Interfaces Housing Housing Materials Die cast Aluminium Housing Housing finish Matte Black IP Rate IP65 Cooling Sensor Thermostat Controlled Fan Dimension 490 x 285 x 205 mm Net Weigh...