background image

www.event-lighting.com.au 

 

 

 

CONTENTS 

 

Safety Instructions 

-  Power input & power Linking 

Product Installation 

-  Fuse replacement 

Diagrams 

-  Lux chart 
-  Dimensions 
-  Fade Mode Chart 

Control Board Operation 

-  DMX address setting 
-  DMX modes setting 
-  Dimmer Speed Setting 
-  Static colour setting 
-  Manual colour setting 
-  Auto run and sound active setting 
-  Master/slave setting 

DMX chart 

Technical specifications   

Warranty 

 

 

 

 

 

Summary of Contents for PRO PAR19x15

Page 1: ...rves the right to revise the manual at any time Information and specifications within this manual are subject to change without notice Event Lighting assumes no liability or responsibility for any errors or omissions Please consult Event Lighting for any clarification or information regarding this item www event lighting com au Ver 3 0 ...

Page 2: ...allation Fuse replacement Diagrams Lux chart Dimensions Fade Mode Chart Control Board Operation DMX address setting DMX modes setting Dimmer Speed Setting Static colour setting Manual colour setting Auto run and sound active setting Master slave setting DMX chart Technical specifications Warranty ...

Page 3: ...device In case of a serious operating problem stop using immediately The maximum ambient temperature is 104 F 40 C Do not operate this device at higher temperatures Power Input Power Linking This device has an auto switching power supply work with input voltage range of 100 240 VAC 50 60 Hz Link up to the maximum 8A DO NOT exceed this number The maximum number of units that can be power linked is ...

Page 4: ...www event lighting com au 3 Lux Chart Dimensions ...

Page 5: ...et warm white or cool white WT To select intensity Dim Auto Pro Pr01 Pr21 To select built in automatic programs Sp000 Sp100 To set speed of auto run Sound Sen 000 100 To set sound active mode and set sound sensitivity level Mas Sla M S To set Master Slave modes UpDate N Y Select to update firmware START Use this fixture to update another fixture s software ReSet N Y To reset factory default settin...

Page 6: ...firm then set the intensity using the UP and DOWN buttons and press ENTER to save new setting Automatic Mode This fixture has 21 built in programs Only Pr21 is multi fixture chases Select Auto Pro in main menu and press ENTER uses the UP and DOWN buttons to select the desired built in program and press ENTER to confirm Set the program speed SP00 SP100 using the UP and DOWN buttons and press ENTER ...

Page 7: ...ures can be upgraded simultaneously via DMX Use fixture A to update fixture B s firmware Set fixture A to Update mode select Y then select START Link fixture A and fixture B with DMX cable then power up fixture B Press Enter on fixture A fixture B s firmware will be copied from fixture A Ensure that fixture A and B are of the same type otherwise damage may occur Only fixture A and B should be in t...

Page 8: ...er on 7 channels Mode Channel Value Function 1 000 255 Red 0 100 2 000 255 Green 0 100 3 000 255 Blue 0 100 4 000 255 White 0 100 5 000 255 Master dimmer coarse 0 100 6 000 255 Master dimmer fine 0 100 7 000 007 Shutter closed No light 008 015 Shutter on 016 119 Strobe slow to fast 1 25Hz 120 127 Shutter on 128 183 Strobe random slow to fast 184 191 Shutter on 192 247 Strobe sound sensitivity from...

Page 9: ...068 Auto run 5 069 080 Auto run 6 081 092 Auto run 7 093 104 Auto run 8 105 116 Auto run 9 117 128 Auto run 10 129 140 Auto run 11 141 152 Auto run 12 153 164 Auto run 13 165 176 Auto run 14 177 188 Auto run 15 189 200 Auto run 16 201 212 Auto run 17 213 224 Auto run 18 225 236 Auto run 19 237 255 Auto run 20 cycle run auto 1 19 9 000 255 Speed of auto programs slow fast or sound sensitivity 10 00...

Page 10: ...ode Channel Value Function 1 000 255 Centre Red 0 100 2 000 255 Centre Green 0 100 3 000 255 Centre Blue 0 100 4 000 255 Centre White 0 100 5 000 255 Inner ring Red 0 100 6 000 255 Inner ring Red 0 100 7 000 255 Inner ring Blue 0 100 8 000 255 Inner ring White 0 100 9 000 255 Outer ring Red 0 100 10 000 255 Outer ring Green 0 100 11 000 255 Outer ring Blue 0 100 12 000 255 Outer ring White 0 100 1...

Page 11: ...main menu 010 058 Standard dimmer 1 059 108 Stage dimmer 2 109 158 TV dimmer 3 159 208 Architecture dimmer 4 209 255 Theartre dimmer 5 9 000 255 Red 0 100 Inner ring 10 000 255 Green 0 100 11 000 255 Blue 0 100 12 000 255 White 0 100 13 000 255 Master dimmer coarse 0 100 14 000 255 Master dimmer fine 0 100 15 000 007 Shutter closed No light 008 015 Shutter on 016 119 Strobe slow to fast 1 25Hz 120...

Page 12: ...00 23 000 007 Shutter closed No light 008 015 Shutter on 016 119 Strobe slow to fast 1 25Hz 120 127 Shutter on 128 183 Strobe random slow to fast 184 191 Shutter on 192 247 Strobe sound sensitivity from low to high 248 255 Shutter on 24 000 009 Dimmer mode as set from main menu 010 058 Standard dimmer 1 059 108 Stage dimmer 2 109 158 TV dimmer 3 159 208 Architecture dimmer 4 209 255 Theatre dimmer...

Page 13: ...acros Manual dimming colour Auto programs Preset colour temperature setting Sound active Beam Angle 25 Beam Angle Options 9 15 50 Dimmer 16 bit 0 100 dimmer Fade Modes Standard Stage TV Architecture Theater Refresh Rate 1200Hz DMX Channel mode 3 4 6 7 10 12 14 24 Power Input Seetronic Outdoor Powerkon Neutrik Powercon DMX Connector Seetronic 3 Pin Outdoor DMX socket 3 5 Pin DMX socket WARRANTY Ple...