12 channels Mode 

RGBW 

Channel

 

Value 

Function

 

000-255 

Red: 0% ~ 100% 

000-255 

Green: 0% ~ 100% 

000-255 

Blue: 0% ~ 100% 

000-255 

RGBW Model : White: 0% ~ 100% 

000-255 

Amber: 0% ~ 100% 

000-255 

UV: 0% ~ 100% 

000-255 

Master Dimmer 0% ~ 100% for CH1, 2, 3, 4, 5, 6 & 8 

000-009 

Strobe OFF 

010-255 

Strobe (slow-fast 1-30Hz) 

 

 

 

 

 

 

 

 

 

000-019 

No Function 

020-039 

RED 100% / GREEN 0% ~ 100% / BLUE 0% 

040-059 

RED 100% ~ 0% / GREEN 100% / BLUE 0% 

060-079 

RED 0% / GREEN 100% / BLUE 0% ~ 100% 

080-099 

RED 0% / GREEN 100% ~ 0% / BLUE 100% 

100-119 

RED 0% ~ 100% / GREEN 0% / BLUE 100% 

120-139 

RED 100% / GREEN 0% / BLUE 100% ~ 0% 

140-159 

RED 100% / GREEN 0% ~100% / BLUE 0% ~ 100% 

160-179 

RED 100%~ 0% / GREEN 100% ~ 0% / BLUE 100% 

180-200 

RED 100% / GREEN 100% / BLUE 100% 

201-204 

Color Temperature 1 

 

Warm 

 

 

 

 

 

Cool 

205-209 

Color Temperature 2 

210-214 

Color Temperature 3 

215-219 

Color Temperature 4 

220-224 

Color Temperature 5 

225-229 

Color Temperature 6 

230-234 

Color Temperature 7 

235-239 

Color Temperature 8 

240-244 

Color Temperature 9 

245-249 

Color Temperature 10 

250-255 

Color Temperature 11 

 

 

 

 

 

10 

000-009 

No Function 

010-049 

R G B W A UV colour switching 

050-090 

36 colour switching 

091-131 

RGBW Model : R G B W A UV colour fading 

132-172 

36 colour fading 

173-213 

Color Macros Fading 

214-255 

Sound active mode 

11 

000-255 

Speed of auto programs (slow ~ fast) or sound sensitivity for CH8 

 

 

12 

000-009 

Use dimmer curve from setting of control board 

010-057 

16 bits Linear dimmer 1 

058-106 

16 bits Non-linear dimmer 2 

Summary of Contents for PAR12x12

Page 1: ...ves the right to revise the manual at any time Information and specifications within this manual are subject to change without notice Event Lighting assumes no liability or responsibility for any errors or omissions Please consult Event Lighting for any clarification or information regarding this item www event lighting com au Ver 2 1 ...

Page 2: ...www event lighting com au 1 CONTENTS Safety Instructions Product Installation Diagrams Control Board Operation DMX chart Technical specifications Warranty ...

Page 3: ...it ONLY use the hanging bracket to carry this device In case of a serious operating problem stop using immediately The maximum ambient temperature is 104 F 40 C Do not operate this device at higher temperatures Power Input Power Linking This device has an auto switching power supply work with input voltage range of 100 240 VAC 50 60 Hz Link up to the maximum 8A DO NOT exceed this number Product In...

Page 4: ...www event lighting com au 3 Lux Chart PAR5X12 PAR12X12 Dimensions PAR5 ...

Page 5: ...W GBA BWA RGA G WA RWA RGBA GBWA RBWA RGWA RGBQA RU GU AU RAU RGBWAU Select static colour ManualC R 000 255 G 000 255 B 000 255 W 000 255 A 000 255 UV 000 255 S 000 S 100 Set intensity of each colour separately for color mixing and strobe rate Auto Pr Pr01 Pr07 Sp000 Sp100 Dim000 Dim255 Select built in automatic programs auto run speed and dimmer level Mas Sla M S Select Master Slave modes Reset N...

Page 6: ...o save new setting Static Colour Mode Entered Static C mode you can select the desired solid color via the UP or DOWN buttons press Enter to save new setting Value Function R Red G Green B Blue W White A Amber UV UV GB Green Blue RG Red Green RB Red Blue RW Red White GW Green White BW Blue White WA White Amber RA Red Amber GA Green Amber BA Blue Amber RGB Red Green Blue RGW Red Green White RBW Red...

Page 7: ... Press Enter to save new setting Set sound active mode Pr 06 Entered Auto Pro mode use Up and Down button to select the built in program Pr 06 press Enter and use Up and Down button to select the sound sensitivity level from Sen000 to Sen100 press Enter to save new setting Set multi fixture chases Pr 07 Before starting go to each fixture and reset the menu to fixture defaults 1 On the master unit ...

Page 8: ...100 3 channels Mode Channel Value Function 1 000 255 Red 0 100 2 000 255 Green 0 100 3 000 255 Blue 0 100 6 channels Mode Channel Value Function 1 000 255 Red 0 100 2 000 255 Green 0 100 3 000 255 Blue 0 100 4 000 255 White 0 100 5 000 255 Amber 0 100 6 000 255 UV 0 100 8 channels Mode Channel Value Function 1 000 255 Red 0 100 2 000 255 Green 0 100 3 000 255 Blue 0 100 4 000 255 White 0 100 5 000...

Page 9: ...D 100 0 GREEN 100 0 BLUE 100 180 200 RED 100 GREEN 100 BLUE 100 201 204 Color Temperature 1 Warm Cool 205 209 Color Temperature 2 210 214 Color Temperature 3 215 219 Color Temperature 4 220 224 Color Temperature 5 225 229 Color Temperature 6 230 234 Color Temperature 7 235 239 Color Temperature 8 240 244 Color Temperature 9 245 249 Color Temperature 10 250 255 Color Temperature 11 10 000 009 No Fu...

Page 10: ...ply 100 240V AC 50 60 Hz Power Consumption w 50 120 Fuse T 1 A 250 V T 2 A 250 V LED 5pcs 12W RGBWA UV 6 in 1 LED 12pcs 12W RGBWA UV 6 in 1 LED Operation Modes DMX auto run sound active master slave manual colour control static colour control Beam Angle 30 Refresh Rate 2940Hz DMX Channel mode 2 3 6 8 12 Power Input Neutrik Powercon Power Output Neutrik Powercon WARRANTY Please refer to your local ...