Preset Ceramic Express Mode Data
FAST SPEED
Segment 1
Segment 2
Segment 3
Segment 4
Rate
570°F/Hr.
570°F/Hr.
570°F/Hr.
200°F/Hr.
Set Point Temperature
200°F
1050°F
Cone Temperature
Minus 256°F
Cone Temperature
Hold Time
User Defined Pre-Heat
(if any)
0 Min.
0 Min.
User Defined Hold (if any)
MEDIUM SPEED
Segment 1
Segment 2
Segment 3
Segment 4
Rate
120°F/Hr.
400°F/Hr.
300°F/Hr.
120°F/Hr.
Set Point Temperature
200°F
1050°F
Cone Temperature
Minus 256°F
Cone Temperature
Hold Time
User Defined Pre-Heat
(if any)
10 Min.
0 Min.
User Defined Hold (if any)
SLOW SPEED
Segment 1
Segment 2
Segment 3
Segment 4
Rate
80°F/Hr.
200°F/Hr.
200°F/Hr.
108°F/Hr.
Set Point Temperature
200°F
1050°F
Cone Temperature
Minus 256°F
Cone Temperature
Hold Time
User Defined Pre-Heat
(if any)
30 Min.
0 Min.
User Defined Hold (if any)