![evenes PPE1 Series Assembly And User'S Manual Download Page 15](http://html1.mh-extra.com/html/evenes/ppe1-series/ppe1-series_assembly-and-users-manual_2442087015.webp)
ELECTRIC INSTANTANEOUS WATER HEATER
PPE1, PPE2, PPVE
15
5 | POWER SETTING
Venting
1.
Shut off electric supplies to the heater
2.
Turn the flow on (turn the hot water tap on) in order to vent the
water installation (for about 15-30 seconds), until the flow of
water becomes constant and even.
3.
Switch on the electric supplies.
Configuration: PPE2, PPVE
Before you supply voltage for the first time, make sure that you set the
heater’s power at appropriate value (always consider the capacity of
your home’s electrical system). Notice: Configuration must be
performed before initial start-up when power supply is switched off. Set
2 (two) switches at proper position to configure a heater. The switches
are located on electronic board. Each switch has 4 (four) positions, they
are described as
P
(power settings) and
F
(other settings). Switch on a
supply power to PPE2 or PPVE a display will show: (PW...) - software
version of control panel, (MSP...) - software version of controller and the
value of rated power that has been set for the heater (PPE2; PPVE).
P
switches settings (for PPE2, PPVE):
•
1, 2 - rated power of heater,
•
3, 4 - type of heating box,
F
switches settings:
•
1, 2, 3 - do not change! keep factory settings intact,
•
4 - ON - blocks access to the heater’s settings.
In this case for PPE2 or PPVE, the display shows the desired
temperature value (which has been adjusted before the heater
is off), the heating icon and other possible working
characteristics.
grey square shows the
switch position
The heater is factory set at NORMAL mode. Change of the modes can only be done by authorised service.