page 13 of 58
4
ELECTRIC CONNECTION
4.1
Electric connection
The following drawing illustrates the EVXS815 electric connection.
The utility managed by the K4 output, depends on parameter u1, as follows:
-
door heating elements (u1 = 0, pre-defined setting)
-
condenser fan (u1 = 1).
For the settings relative to the parameters, see chapter 9 “CONFIGURATION”.
The utility managed by the K5 output, depends on parameter u11, as follows:
-
cabinet light (u11 = 0, pre-defined setting)
-
needle probe heating (u11 = 1)
-
UV light (u11 = 2).
For the settings relative to the parameters, see chapter 9 “CONFIGURATION”.
The serial port is for the connection of the controller to the following additional products:
-
EVKEY programming key
-
Parameters Manager set-up software system
-
RICS plants monitoring and surveillance systems
-
Device for recording data, for downloading the data recorded (via USB), for uploading and downloading
EVUSBREC01 configuration parameters.
The port must not be used simultaneously with more that one of these products.