144V229E4.00
·
Vcolor 229/249 M/L
11/2021
| 67 |
Par. Description
MU
Range
Default
EVAPORATOR/CONDENSER FAN group
F0
Evaporator fans in normal operating mode.
With
F0
=0,cyclescanbemanagedbysetting
F14, F15
.
0
= Cyclical;
1
=AlwaysON;
2
=Activedependingonloads;
3
= Temperature-controlled (
F1
relating to temperature regulation);
4
=Activedependingonloadsandtemperature-controlled(
F1
relating to temperature regulation);
5
=WithON/OFFcycles,whilethecompressorisoff,onthebasisofparameters
F14
and
F15
;
6
= Thermostat-controlled based on
F1
(as an absolute value);
7
= Thermostat-controlled based on
F1
with the compressor on (as an absolute value);
8
=WithON/OFFcycles;inthiscasethehumidityprobeperformsaread-onlyfunctionand
doesnottakepartinregulation.
---
0...8
1
F1
Evaporator fan regulation threshold with
F0
=3,4(relativetothesetpoint).
°C/°F -99.0...99.0
-4.0
F2
Evaporator fan mode during defrosting.
0
=OFF;
1
= ON;
2
= Depends on
F0
.
---
0...2
0
F3
Maximum evaporator fan post-dripping stoppage time.
min
0...15
2
F4
FanOFFtimeinenergysavingmode.
Sx10
0...240
30
F5
FanONtimeinenergysavingmode.
Sx10
0...240
30
F6
Fanspeedforcingduringenergysavingmode.
%
0...100
0
F7
Threshold relative to the setpoint for fan restart after a defrost.
°C/°F -99.0...99.0
5.0
F8
Evaporator setpoint differential.
°C/°F
1.0...15.0
2.0
F9
Evaporator fan switch-off delay from compressor switch-off.
s
0...240
0
F10
Fanspeedforcingduringdehumidification.
%
0...100
0
F11
Condenser fan mode.
0
= Temperature-controlled;
1
=Temperature-controlledifcompressorOFF;
2
= Temperature-controlled if compressor ON;
3
=Temperature-controlledifcompressoranddefrostOFF.
---
0...3
2
F12
Condenser fan setpoint.
°C/°F
-0.0...99.0
15.0
F13
Condenser fan switch-off delay from compressor switch-off.
s
0...240
0
F14
FanOFFtimeintheabsenceofregulationwith
F0
=0.
F14
=0and
F15
>0fansarealwayson.
Sx10
0...240
60
F15
FanONtimeintheabsenceofregulationwith
F0
=0.
F15
=0fansremainstopped.
Sx10
0...240
10
F16
Evaporator fan switch-on delay from door closure.
s
0...240
0
F19
Evaporator minimum speed.
%
0...100
20
F20
Evaporator maximum speed.
%
0...100
100
F21
Evaporator fan boost speed.
%
0...100
75
F22
Boost time at evaporator fan switch-on.
s
0...240
5
F23
Evaporator fan minimum calibration speed value.
%
0...100
35
F24
Evaporator fan maximum calibration speed value.
%
0...100
65
F25
Speedvalue1.
%
0...100
20
F26
Speedvalue2.
%
0...100
40
F27
Speedvalue3.
%
0...100
60
F28
Speedvalue4.
%
0...100
80
F29
Speedvalue5.
%
0...100
100
F30
Differential for activation of the second condenser fan.
°C/°F
-0.0...99.0
0.0
F0b
EvaporatorfanmodeinmodeBnormaloperation.Sameas
F0
.
---
0...8
1
F2b
EvaporatorfanmodeinmodeBdefrost.Sameas
F2
.
---
0...2
0
F3b
Maximumevaporatorfanpost-drippingstoppagetime,modeB.
min
0...15
2
ENERGY SAVING group
ES0
Energy saving mode.
0
=1level(Disabled/Highsaving);
1
= 3 levels (Disabled/Low saving/Medium saving/High saving).
num
0/1
0