Evco EV8318 Quick Start Manual Download Page 4

EVCO S.p.A. | EV8318 | Instr

 

uction sheet ver. 2.0 | Code 1048318E203 | Page 4 of 4 | PT 47/18 

70 

 

 

 

Lb 

 

 

 

 

 

 

MODBUS baud rate 

 

 

 

0  = 2,400 baud 

1  = 4,800 baud 

2  = 9,600 baud 

3  = 19,200 baud 

71 

 

LP 

 

 

MODBUS parity 

 

0  = none 

1  = odd 

2  = even 

 

10 

ALARMS 

 

LABEL 

RESET 

TO CORRECT 

Chamber probe 

automatic 

-  check P0 

Top probe 

automatic 

-  check the integrity of the probe 

Floor probe 

automatic 

-  check electrical connection 

Steam probe 

automatic 

 

Board probe 

automatic 

check operating temperature  

time flashing 

 

manual 

 

set time and day of the week 

Chamber high temp. 

automatic 

check A1 and A3 

Top high temp. 

automatic 

check A1 and A3 

Floor high temp. 

automatic 

check A1 and A3 

Controller high temp. 

automatic 

check A4 

Door 

automatic 

check i0, i1, i3 and i4 

Power failure 

 

 

manual 

 

 

-  touch a key 

-  check A5 

-  check electrical connection 

Thermal switch 

manual 

check i0, i1, i3 and i4 

Top thermal switch 

manual 

check i0, i1, i3 and i4 

Floor thermal switch 

manual 

check i0, i1, i3 and i4 

 

11 

TECHNICAL SPECIFICATIONS 

 

Purpose of the control device: 

function controller. 

Construction of the control device: 

built-in electronic device. 

Housing: 

black, self-extinguishing. 

Category of heat and fire resistance: 

D. 

Measurements: 

 

76.4  x  148.4  x  77.0  mm  (3  x  5  13/16  x  3 

in). 

Mounting methods for the control device: 

 

to  be  fitted  to  a  panel,  screwed-in  brackets 

provided. 

Degree  of  protection  provided  by  the  cover-

ing: 

IP65 (front). 

 

Connection method: 

 

 

 

plug-in  screw  terminal  blocks 

for wires up to 2.5 mm² 

Pico-Blade connector 

 

female Micro USB connector. 

 

Maximum permitted length for connection cables: 

power supply: 10 m (32.8 ft) 

analogue inputs: 10 m (32.8 ft) 

digital inputs: 10 m (32.8 ft) 

digital outputs: 10 m (32.8 ft) 

Operating temperature: 

from 0 to 60 °C (from 32 to 140 °F). 

Storage temperature: 

from -25 to 70 °C (from -13 to 158 °F). 

Operating humidity: 

 

relative  humidity  without  condensate  from 

10 to 90%. 

Pollution status of the control device: 

3. 

Compliance: 

 

 

 

RoHS 2011/65/EC 

 

WEEE 2012/19/EU 

 

REACH  (EC)  Regulation  no. 

1907/2006 

EMC 2014/30/EU 

LVD 2014/35/EU. 

Power supply: 

 

115... 230 VAC (+10% -15%), 50/60 Hz (±3 

Hz), max. in EV8318J9 

 

 

24  VAC  (+10%  -15%),  50/60  Hz  (±3  Hz), 

max. in EV8318J4  

Earthing methods for the control device: 

none. 

Rated impulse-withstand voltage: 

2.5 KV 

Over-voltage category: 

II. 

Software class and structure: 

A. 

Clock: 

built-in secondary lithium battery. 

Clock drift: 

≤ 60 s/month at 25 °C (77 °F).

 

Clock  battery  autonomy  in  the  absence  of  a 

power supply: 

> 24 h at 25 °C (77 °F). 

 

Clock battery charging time: 

 

24  h  (the  battery  is  charged  by  the  power 

supply of the device). 

Analogue inputs: 

 

 

2  for  J/K  thermocouples  or  Pt  100  2-wire 

probes  (chamber  probe  or  top  and  floor 

probes). 

thermocou-

ples: 

Measurement field: 

from 0 to 700 °C (from 32 to 999 °F). 

Resolution: 

1 °C (1 °F). 

thermocou-

ples: 

Measurement field: 

from 0 to 999 °C (from 32 to 999 °F). 

Resolution: 

1 °C (1 °F). 

Pt 100 probes: 

 

Measurement field: 

from 0 to 650 °C (from 32 to 999 °F). 

Resolution: 

1 °C (1 °F). 

Digital inputs: 

1 dry contact (multi-purpose 2). 

Dry contact: 

Contact type: 

3.3 V, 1 mA 

 

 

Protection: 

none. 

Other inputs: 

 

can be configured for analogue input (steam probe) or digi-

tal input (multi-purpose input 1). 

Digital outputs: 

 

 

8 with electro-mechanical relay (K1...K8 relays ). 

The  maximum  overall  current  permitted  for  loads  is 

15 A. 

K1 relay: 

SPST, 16 A res. @ 250 VAC 

K2...K7 relay : 

SPST, 8 A res. @ 250 VAC. 

K8 relay: 

SPDT, 8 A res. @ 250 VAC. 

Type 1 or Type 2 actions: 

Type 1. 

Additional  features  of  Type  1  or  Type  2  ac-

tions: 

C. 

 

Displays: 

2.8 inch TFT colour graphic display. 

Alarm buzzer: 

built-in. 

Built-in sensors: 

1 (operating temperature). 

Communications ports: 

 

 

 

1  TTL  MODBUS  slave  port  for  EVJKEY  pro-

gramming key or for TTL/RS-485 (BMS) serial 

interface 

1 USB port (set up recipe book). 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.B. 

The device must be disposed of according to local regulations governing the collection 

of electrical and electronic equipment. 

 

This document and the solutions contained therein are the intellectual property of EVCO and thus pro-

tected by the Italian Intellectual Property Rights Code (CPI). EVCO imposes an absolute ban on the full 

or partial reproduction and disclosure of the content other than with the express approval of EVCO. The 

customer (manufacturer, installer or end-user) assumes all responsibility for the configuration of the de-

vice. 

EVCO  accepts  no  liability  for  any  possible  errors in  this  document  and  reserves  the  right  to make  any 

changes, at any time without prejudice to the essential functional and safety features of the equipment.

 

 

 

EVCO S.p.A. 

Via Feltre 81, 32036 Sedico (BL) ITALY 

Tel. 0437/8422 | Fax 0437/83648 

email [email protected] web www.evco.it

 

Summary of Contents for EV8318

Page 1: ...following the instructions given in the section MEASUREMENTS AND INSTALLATION 2 Power up the device as set out in the section ELECTRICAL CONNECTION an internal test will start up The test normally takes a few seconds when it is finished the display will switch off 3 Configure the device as shown in the section Setting configuration parameters Recommended configuration parameters for first time use...

Page 2: ...he ENERGY SAVING key for 3 s the display will show the value in yellow 2 Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key within 15 s to set the value 3 Touch the INTERACTIVE 3 key or take no action for 15 s If the operating logic has independent regulation of the top and floor temperature P2 1 when the energy saving function is active the switch on time of the top and floor heaters is calcula...

Page 3: ...grammed switch on 0 no 1 yes 26 c6 0 activate overheating at power on 0 no 1 yes effective only if P2 0 27 c7 150 chamber temperature threshold for end of overheating 0 999 C F 0 on reaching the working setpoint effective only if P2 0 28 c8 60 maximum duration of energy saving 0 240 min 0 until manual deactiva tion not effective if activated by digital input 29 c9 50 percentage reduction time top ...

Page 4: ...ulse withstand voltage 2 5 KV Over voltage category II Software class and structure A Clock built in secondary lithium battery Clock drift 60 s month at 25 C 77 F Clock battery autonomy in the absence of a power supply 24 h at 25 C 77 F Clock battery charging time 24 h the battery is charged by the power supply of the device Analogue inputs 2 for J K thermocouples or Pt 100 2 wire probes chamber p...