SETTINGS
8.1 Setting configuration parameters
N.B.
Changing parameter P2 causes the value of the parameters whose unit of measure-
ment is °C or °F to be changed automatically.
Make sure that the device is switched off.
1.
Touch the INTERACTIVE 4 key: the display will show the “Con-
figuration” menu.
2.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key to se-
lect “Service”.
3.
Touch the INTERACTIVE 3 key: the display will show “Password”
in yellow.
4.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key within
15 s to set “-19”.
5.
Touch the INTERACTIVE 3 key: the display will show the “Ser-
vice” menu.
6.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key to se-
lect a parameter.
7.
Touch the INTERACTIVE 3 key: the display will show the parame-
ter in yellow.
8.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key within
15 s to set the value.
9.
Touch the INTERACTIVE 3 key (or take no action for 15 s).
10.
Touch the INTERACTIVE 4 key to exit the procedure (or take no
action for 60 s).
8.2
Setting the time and day of the week
N.B.
Do not disconnect the device from the mains in the two minutes after setting the time
and day of the week.
Make sure that the device is switched off.
1.
Touch the INTERACTIVE 4 key: the display will show the “Con-
figuration” menu.
2.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key to se-
lect “Clock”.
3.
Touch the INTERACTIVE 3 key.
4.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key to se-
lect “Time”.
5.
Touch the INTERACTIVE 3 key: the display will show the time in
yellow.
6.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key within
15 s to set the value.
7.
Touch the INTERACTIVE 3 key: the display will show the minutes
in yellow.
8.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key within
15 s to set the value.
9.
Touch the INTERACTIVE 3 key (or take no action for 15 s).
10.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key to se-
lect “Day”.
11.
Touch the INTERACTIVE 3 key: the display will show the day in
yellow.
12.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key within
15 s to set the value.
13.
Touch the INTERACTIVE 3 key (or take no action for 15 s).
14.
Touch the INTERACTIVE 4 key to exit the procedure (or take no
action for 60 s).
8.3
Restoring factory settings (default)
N.B.
Check that the factory settings are appropriate; see the section CONFIGURATION PA-
RAMETERS.
Make sure that the device is switched off.
1.
Touch the INTERACTIVE 4 key: the display will show the “Con-
figuration” menu.
2.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key to se-
lect “Service”.
3.
Touch the INTERACTIVE 3 key: the display will show “Password”
in yellow.
4.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key within
15 s to set “149”.
5.
Touch the INTERACTIVE 3 key: the display will show the “Ser-
vice” menu.
6.
Touch the INTERACTIVE 1 key or the INTERACTIVE 2 key to se-
lect “Restore default”.
7.
Touch the INTERACTIVE 3 key for 3 s: the display will show a
tick.
8.
Touch the INTERACTIVE 4 key to exit the procedure beforehand
(the reset will not be carried out).
9
CONFIGURATION PARAMETERS
NO. PAR.
DEF. ANALOGUE INPUTS
MIN... MAX.
1
P0
0
type of probe
0 = J
1 = K
2 = Pt 100 2-wire
2
P1
0
unit of measurement
0 = °C
1 = °F
3
P2
0
operating logic
0 = independent regulation
of the top and floor
power
1 = independent regulation
of the top and floor
temperature
4
P3
1
type of steam injection
0 = disabled
1 = manual and automatic
(with t8, t9 and t10) if
generator is on
2 = manual and automatic
(with t8, t9 and t10),
with digital input active
and if generator is on
3 = manual and automatic
(with t8, t9 and t10),
thermoregulated
(with
t1, t2 and t3) and if
generator is on
5
CA1
0
chamber probe offset
-25... 25 °C/°F
if P2 = 1, top probe offset
6
CA2
0
floor probe offset
-25... 25 °C/°F
7
CA3
0
steam probe offset
-25... 25 °C/°F
NO. PAR.
DEF. REGULATION
MIN... MAX.
8
r0
5
setpoint chamber differential
1... 99 °C/°F
if P2 = 1, top setpoint and
floor setpoint differential
effective if r10 = 0
9
r1
0
minimum chamber setpoint
0 °C/°F... r2
if P2 = 1, minimum top set-
point
10
r2
300
maximum chamber setpoint
r1... 999 °C/°F
if P2 = 1, maximum top set-
point
11
r3
130
chamber setpoint
r1... r2
if P2 = 1, top setpoint
12
r4
0
minimum floor setpoint
0 °C/°F... r5
13
r5
300
maximum floor setpoint
r4... 999 °C/°F
14
r6
130
floor setpoint
r4... r5
15
r7
0
constraint between top and floor
powers
0 = disabled
1 = changing
a
power
causes the other to be
changed
automatically
so that the sum of the
two is always 100
16
r8
80
cycle time for top and floor
heaters on
1... 999 s
if P2 = 1, cycle time for top
and floors heaters on in en-
ergy saving mode
if P2 = 1 and r10 > 0, cycle
time PI
17
r9
0
minimum time top and floor
heaters on and off
0... 240 s
we recommend > 10 s
18
r10
50
proportional band
0... 99 °C/°F
0 = on-off control
effective only if P2 = 1
19
r11
80
integral action time
0... 999 s
0 = P control
effective only if P2 = 1
NO. PAR.
DEF. GENERAL SETTINGS
MIN... MAX.
20
c0
15
time buzzer on from end of
cooking cycle
-1... 120 s
-1 = until silencing
21
c1
0
activate buzzer for 1 s at end of
the cooking phase
0 = no
1 = yes
22
c2
60
keyboard
inactivity
time
to
switch off the device from
weekly programmed switch-on
activation
0... 240 min
0 = disabled
23
c3
10
high
chamber
temperature
threshold for locked display
(relative to chamber setpoint)
0... 99 °C/°F
chamber se c3
0 = disabled
24
c4
10
low
chamber
temperature
threshold for locked display
(relative to chamber setpoint)
0... 99 °C/°F
chamber setpoint - c4
0 = disabled
25
c5
1
enable
weekly
programmed
switch-on
0 = no
1 = yes
26
c6
0
activate overheating at power-on
0 = no
1 = yes
effective only if P2 = 0
27
c7
150
chamber temperature threshold
for end of overheating
0... 999 °C/°F
0 = on reaching the working
setpoint
effective only if P2 = 0
28
c8
60
maximum duration of energy
saving
0... 240 min
0 = until manual deactiva-
tion
not effective if activated by
digital input
29
c9
50
percentage reduction time top
and floor heaters on in energy
saving mode
0... 100 %
effective only if P2 = 0
30
c10
10
duration of controller cleaning
1... 120 s
NO. PAR.
DEF. STEAM INJECTION
MIN... MAX.
31
t1
100
steam setpoint
0... 500 °C/°F
32
t2
5
steam setpoint differential
1... 99 °C/°F
33
t3
50
steam temperature threshold for
injection stoppage (relative to
steam setpoint)
0... 999 °C/°F
steam setpoint - t3
injection available on reach-
ing steam setpoint
34
t4
1
activate automatic steam injec-
tion cycles at start-up of cooking
cycle
0 = no
1 = yes
35
t5
1
deactivate automatic steam in-
jection cycles at end of cooking
cycle
0 = no
1 = yes
36
t6
0
steam generator on at power-on
0 = no
1 = yes
37
t7
2
value available with quick setting
of automatic steam injection cy-
cles
0 = injection time on
1 = injection time on and in-
jection time off
2 = injection time on, injec-
tion time off and num-
ber of automatic cycles
3 = injection time on and
number of automatic cy-
cles
38
t8
2
steam injection default time on
with quick setting
1... 99 s
39
t9
10
steam injection default time off
with quick setting
1... 999 s
if t7 = 1 or 2, injection time
off
40
t10
3
number of automatic steam in-
jection cycles default
-1... 20
-1 = until
generator
is
switched off
if t7 = 0 or 1, number of
automatic cycles
NO. PAR.
DEF. ALARMS
MIN... MAX.
41
A0
10
temperature alarm switch off dif-
ferential
1... 99 °C/°F
42
A1
0
high temperature alarm thresh-
old
0... 500 °C/°F
43
A2
0
high temperature alarm delay
and delay after modifying set-
point
0... 240 min
44
A3
0
high temperature alarm type
0 = disabled
1 = absolute
2 = relative to setpoint
45
A4
70
high
operating
temperature
alarm threshold
0... 88 °C/175 °F
0 = disabled
46
A5
240
power failure duration due to in-
terruption of cooking cycle
0... 240 min
0 = disabled
NO. PAR.
DEF. DIGITAL INPUTS
MIN... MAX.
47
i0
0
activation multi-purpose input 1
0 = with contact closed
1 = with contact open
48
i1
6
multi-purpose input 1 function
(option
6
effective
only
if
P3 = 2)
0 = disabled
1 = suction hood on (door
open alarm)
2 = steam injection off, top
and floor heaters off,
suction hood on (door
open alarm)
3 = switches device on/off
4 = steam generator off, top
and floor heaters off
(thermal switch alarm)
5 = energy saving activa-
tion/deactivation
6 = enable steam injection
49
i2
0
door open alarm delay and
thermal switch alarm delay from
multi-purpose input 1
0... 120 s
50
i3
0
multi-purpose input 2 activation
0 = with contact closed
1 = with contact open
51
i4
6
multi-purpose input 2 function
(option
6
effective
only
if
P3 = 2)
0 = disabled
1 = suction hood on (door
open alarm)
2 = steam injection off, top
and floor heaters off,
suction hood on (door
open alarm)
3 = switches device on/off
4 = steam generator off, top
and floor heaters off
(thermal switch alarm)
5 = energy saving activa-
tion/deactivation
6 = enable steam injection
52
i5
0
door open alarm delay and
thermal switch alarm delay from
multi-purpose input 2
0... 120 s
NO. PAR.
DEF. DIGITAL OUTPUTS
MIN... MAX.
53
u0
0
opening vent
0 = with contact closed
1 = with contact open
54
u1
10
time vent open from end of
cooking cycle
0... 600 s
-1 = open until closed by
pressing key
55
u2
10
time suction hood on
0... 999 s
0 = switching on/off by key
56
u6
60
operating temperature threshold
when electronics compartment
fans on and device off
20... 65 °C/65... 150 °F
fans always on with device on
and device sensor in alarm
mode
57
u7
10
u6 differential
1... 99 °C/°F
58
u8
0
activate chamber light flashing
for 10 s at end of the cooking
cycle
0 = no
1 = yes
59
u1c
4
K1 output configuration
0 = disabled
1 = top heaters
2 = floor heaters
3 = chamber light
4 = steam generator
5 = steam injection
6 = venting
7 = suction hood
8 = electronics compartment
fans
9 = on/stand-by
10 = sound
60
u2c
5
K2 output configuration
0 = disabled
1 = top heaters
2 = floor heaters
3 = chamber light
4 = steam generator
5 = steam injection
6 = venting
7 = suction hood
8 = electronics compartment
fans
9 = on/stand-by
10 = sound
61
u3c
6
K3 output configuration
0 = disabled
1 = top heaters
2 = floor heaters
3 = chamber light
4 = steam generator
5 = steam injection
6 = venting
7 = suction hood
8 = electronics compartment
fans
9 = on/stand-by
10 = sound
62
u4c
3
K4 output configuration
0 = disabled
1 = top heaters
2 = floor heaters
3 = chamber light
4 = steam generator
5 = steam injection
6 = venting
7 = suction hood
8 = electronics compartment
fans
9 = on/stand-by
10 = sound
63
u5c
1
K5 output configuration
0 = disabled
1 = top heaters
2 = floor heaters
3 = chamber light
4 = steam generator
5 = steam injection
6 = venting
7 = suction hood
8 = electronics compartment
fans
9 = on/stand-by
10 = sound
64
u6c
2
K6 output configuration
0 = disabled
1 = top heaters
2 = floor heaters
3 = chamber light
4 = steam generator
5 = steam injection
6 = venting
7 = suction hood
8 = electronics compartment
fans
9 = on/stand-by
10 = sound
65
u7c
7
K7 output configuration
0 = disabled
1 = top heaters
2 = floor heaters
3 = chamber light
4 = steam generator
5 = steam injection
6 = venting
7 = suction hood
8 = electronics compartment
fans
9 = on/stand-by
10 = sound
66
u8c
8
K8 output configuration
0 = disabled
1 = top heaters
2 = floor heaters
3 = chamber light
4 = steam generator
5 = steam injection
6 = venting
7 = suction hood
8 = electronics compartment
fans
9 = on/stand-by
10 = sound
NO. PAR.
DEF. SECURITY
MIN... MAX.
67
PA1
426
first level password
-99... 999
68
PA2
824
second level password
-99... 999
NO. PAR.
DEF. MODBUS
MIN... MAX.
69
LA
247
MODBUS address
1... 247