EVCO S.p.A. | EV3802 | Instruction sheet ver. 2.0 | Code 1043802E203 | Page 1 of 3 | PT 49/20 

EV3802 

Basic controllers for blast chillers 

 

 

 

 

ENGLISH 

230 VAC or 115 VAC power supply (according to the model) 

cabinet probe and needle probe (PTC/NTC) 

door switch/multi-purpose input 

compressor relay 16 A res. @ 250 VAC 

alarm buzzer 

TTL  MODBUS  slave  port  for  EVconnect  app,  EPoCA  remote  monitoring  system  or  for 

BMS 

operation with EV3KEY programming key. 

 

Purchasing code 

Power supply 

EV3802N7 

230 VAC 

EV3802N5 

115 VAC 

 

MEASUREMENTS AND INSTALLATION 

Measurements in mm (inches). To be fitted to a panel, snap-in brackets provided. 

 

 

 

INSTALLATION PRECAUTIONS 

the thickness of the panel must be between 0.8 and 2.0 mm (1/32 and 1/16 in) 

ensure  that  the  working  conditions  are  within  the  limits  stated  in  the  TECHNICAL 

SPECIFICATIONS section 

do not install the device close to heat sources, equipment with a strong magnetic field, 

in places subject to direct sunlight, rain, damp, excessive dust, mechanical vibrations 

or shocks 

in compliance with safety regulations, the device must be installed properly to ensure 

adequate  protection  from  contact  with  electrical  parts.  All  protective  parts  must  be 

fixed in such a way as to need the aid of a tool to remove them. 

 

ELECTRICAL CONNECTION 

 

 

N.B. 

-  use cables of an adequate section for the current running through them 

-  to reduce any electromagnetic interference, locate the power cables as far away as 

possible from the signal cables. 

 

 

 

PRECAUTIONS FOR ELECTRICAL CONNECTION 

if using an electrical or pneumatic screwdriver, adjust the tightening torque 

if the device is moved from a cold to a warm place, humidity may cause condensation 

to form inside. Wait for about an hour before switching on the power 

make  sure  that  the  supply  voltage, electrical  frequency  and  power are  within  the  set 

limits. See the section TECHNICAL SPECIFICATIONS 

disconnect the power supply before carrying out any type of maintenance 

do not use the device as a safety device 

for repairs and for further information, contact the EVCO sales network. 

 

FIRST-TIME USE 

1. 

Carry out the installation following the instructions given in the section MEASUREMENTS 

AND INSTALLATION

2. 

Power  up  the  device  as  set  out  in  the  section  ELECTRICAL  CONNECTION:  an  internal 

test will start up. 

 

The test normally takes a few seconds; when it is finished the display will switch off. 

3. 

Configure the device as shown in the section Setting configuration parameters

 

Recommended configuration parameters for first-time use: 

PAR. 

DEF. 

PARAMETER 

MIN... MAX. 

P0 

type of probe 

0  = PTC 

1  = NTC 

P2 

temperature measurement unit 

0  = °C 

1  = °F 

u0 

 

 

auxiliary output configuration 

 

0  = defrosting 

1  = evaporator fans 

 

 

Then  check  that  the  remaining  settings  are  appropriate;  see  the  section  CONFIGURA-

TION PARAMETERS

4. 

Disconnect the device from the mains. 

5. 

Make  the  electrical  connection  as  shown  in  the  section  ELECTRICAL  CONNECTION, 

without powering up the device. 

6. 

For  the  connection  in  an  RS-485  network  connect  the  interface  EVIF22TSX  or 

EVIF23TSX,  to  use  the  device  with  the EPoCA  remote  monitoring  system,  connect  the 

EVIF25TWX  module,  to  use  the  device  with  the  APP  EVconnect  connect  the  interface 

EVIF25TBX;  see  the  relevant  instruction  sheets.  If  EVIF22TSX  or  EVIF23TSX  is 

used, set parameter bLE to 0

7. 

Power up the device again. 

 

 

 

 

 

 

 

 

 

 

 

 

 

USER INTERFACE AND MAIN FUNCTIONS 

 

 

4.1 

Switching the device on/off 

Power up/disconnect the device. 

If the device is switched on and no cycle is active, the display will show the cabinet tempera-

ture. 

If the display shows an alarm code, see the section ALARMS

If  no  cycle  is  active, after  10  s have  elapsed without  the  keys  being  pressed,  the  display  will 

automatically switch off, except for the low consumption LEDs. 

When 60 s have elapsed without the keys being pressed, the display will show the “Loc" label 

and the keypad will lock automatically. 

LED 

ON 

OFF 

FLASHING 

 

compressor 

switched 

on 

compressor 

switched 

off 

compressor protection in progress 

 

 

defrost active 

 

 

dripping active 

 

 

evaporator fans on 

 

evaporator fans off 

 

evaporator fan delay in progress 

 

 

temperature  controlled 

cycle active 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-  temperature controlled cycle se-

lected 

-  test  to  check  needle  probe  is 

correctly  inserted  in  progress; 

when  time  controlled  cycle  LED 

is  on,  test  has  failed  and  time 

controlled cycle is active 

-  when  alarm  LED  is  on,  blast 

chilling/freezing  has  failed  and 

is active 

-  when  alarm  LED  flashes,  blast 

chilling/freezing  has  failed  and 

conservation is active 

 

conservation active 

 

 

-  setpoint during conservation be-

ing set 

 

alarm active 

 

 

 

°C/°F 

temperature displayed 

 

 

 

min 

 

 

time displayed 

 

 

 

 

residual  time  maximum  duration 

of  temperature  controlled  blast 

chilling/freezing displayed  

 

time controlled cycle is 

selected 

 

time controlled cycle active 

 

 

4.2 

Switching the display back on 

Touch a key. 

 

4.3 

Unlocking the keypad 

Touch a key for 1 s: the display will show the label “UnL”. 

 

4.4 

Activating an operating cycle 

Check that the keypad is not locked and that defrosting is not active. 

1. 

 

Touch the SET key to select a cycle. 

 

LAB. 

LED 

DESCRIPTION 

 

PoS 

 

time controlled blast chilling and conservation (if E0 = 0 or 1) 

 

nEG 

 

time controlled blast freezing and conservation (if E0 = 1 or 2) 

 

PoS 

 

temperature controlled blast chilling and conservation (if E0 = 0 

or 1) 

 

nEG 

 

temperature controlled blast freezing and conservation (if E0 = 1 

or 2) 

2. 

 

Touch the START/STOP key within 15 s. 

 

4.5 

Activating the last cycle carried out 

Check that the keypad is not locked and that defrosting is not active. 

1. 

 

Touch the SET key. 

2. 

 

Touch the START/STOP key again within 15 s. 

 

4.6 

Interrupting an operating cycle 

Check that the keypad is not locked. 

1. 

 

Touch the START/STOP key for 2 s. 

 

4.7 

Setting the cabinet setpoint during conservation 

Check that the keypad is not locked. 

1. 

 

Touch the SET key. 

2. 

 

Touch the UP or DOWN key within 15 s to set the value. 

3. 

 

Touch the SET key (or take no action for 15 s). 

The setting is temporary: when a new cycle is activated (and after a power failure), the device 

will restore the r9/rA values. 

 

4.8 

Activating manual defrost 

Check that the keypad is not locked and that blast chilling/freezing is not active. 

1. 

 

Touch the UP key for 4 s. 

 

4.9 

Silencing the buzzer 

Touch a key. 

 

OPERATING CYCLES 

5.1 

Initial information 

Cycles managed: 

time controlled blast chilling and conservation 

time controlled blast freezing and conservation 

temperature controlled blast chilling and conservation 

temperature controlled blast freezing and conservation. 

Before each temperature controlled cycle, a test is run to check that the needle probe is cor-

rectly inserted. 

The test consists of two phases: if the first one is completed successfully, the second one is not 

carried out. 

The  first  phase  is  completed  successfully  if  [(needle  temperature  -  cabinet  temperature)  > 

threshold rc] 3 times out of 5, checked every 10 s. The second phase is completed successfully 

if [(needle temperature - cabinet temperature) > 1 °C/°F] 6 times out of 8 (compared to previ-

ous test), checked every (duration rd/8) s. 

If the test fails, the corresponding time controlled cycle is activated. 

 

5.2 

Activating time controlled blast chilling/freezing and conservation  

Check that the keypad is not locked and that defrosting is not active. 

1. 

 

Touch the SET key to select a cycle. 

 

LAB. 

LED 

DESCRIPTION 

 

PoS 

 

time controlled blast chilling and conservation (if E0 = 0 or 1) 

 

nEG 

 

time controlled blast freezing and conservation (if E0 = 1 or 2) 

2. 

 

Touch the DOWN key within 15 s to see the duration of the blast 

chilling/freezing. 

3. 

 

Touch the SET key. 

4. 

 

Touch the UP or DOWN key within 15 s to set the value. 

5. 

 

Touch the SET key (or take no action for 15 s). 

6. 

 

Touch the DOWN key within 15 s to see the cabinet setpoint dur-

ing blast chilling/freezing. 

7. 

 

Touch the SET key. 

8. 

 

Touch the UP or DOWN key within 15 s to set the value. 

9. 

 

Touch the SET key (or take no action for 15 s). 

10. 

 

Touch the DOWN key within 15 s to see the cabinet setpoint dur-

ing conservation. 

11. 

 

Touch the SET key. 

12. 

 

Touch the UP or DOWN key within 15 s to set the value. 

13. 

 

Touch the SET key (or take no action for 15 s). 

14. 

 

Touch the START/STOP key within 15 s. 

The settings are temporary: when a new cycle is activated (and after a power failure), the de-

vice will restore the r1/r2, r7/r8 and r9/rA values. 

 

Information about the active cycle 

PHASE 

DISPLAY 

blast  chilling/freezing  ac-

tive 

residual time blast chilling/freezing cycle 

 

end blast chilling/freezing 

End (press a key) 

 

conservation active 

cabinet temperature 

 

Viewing other information about the active cycle 

Check that the keypad is not locked. 

1. 

 

Touch the DOWN key to view the type of active cycle. 

 

LAB. 

LED 

DESCRIPTION 

 

PoS 

 

time controlled blast chilling and conservation 

 

nEG 

 

time controlled blast freezing and conservation 

2. 

 

Touch the DOWN key again to view the cabinet temperature. 

3. 

 

Touch the SET key (or take no action for 15 s) to exit the proce-

dure. 

 

After a power failure during a cycle, the cycle is automatically reactivated from the phase it was 

in at the moment the power failed. If power fails during blast chilling/freezing, the count is re-

sumed with a maximum error of 10 min. 

 

5.3 

Activating temperature controlled blast chilling/freezing and conservation 

Check that the keypad is not locked and that defrosting is not active. 

1. 

 

Touch the SET key to select a cycle. 

 

LAB. 

LED 

DESCRIPTION 

 

PoS 

 

temperature controlled blast chilling and conservation (if E0 = 0 

or 1) 

 

nEG 

 

temperature controlled blast freezing and conservation (if E0 = 1 

or 2) 

2. 

 

Touch  the  DOWN key within  15  s  to  view  the  product  tempera-

ture at the end of blast chilling/freezing.  

3. 

 

Touch the SET key. 

4. 

 

Touch the UP or DOWN key within 15 s to set the value. 

5. 

 

Touch the SET key (or take no action for 15 s). 

6. 

 

Touch the DOWN key within 15 s to view the maximum duration 

of blast chilling/freezing. 

7. 

 

Touch the SET key. 

8. 

 

Touch the UP or DOWN key within 15 s to set the value. 

9. 

 

Touch  the  DOWN  key  within  15  s  to  view  the  cabinet  setpoint 

during blast chilling/freezing. 

10. 

 

Touch the SET key. 

11. 

 

Touch the UP or DOWN key within 15 s to set the value. 

12. 

 

Touch the SET key (or take no action for 15 s). 

13. 

 

Touch  the  DOWN  key  within  15  s  to  view  the  cabinet  setpoint 

during conservation. 

14. 

 

Touch the SET key. 

15. 

 

Touch the UP or DOWN key within 15 s to set the value. 

16. 

 

Touch the SET key (or take no action for 15 s). 

17. 

 

Touch the START/STOP key within 15 s. 

The settings are temporary: when a new cycle is activated (and after a power failure), the de-

vice will restore the r3/r4, r5/r6, r7/r8 and r9/rA values. 

 

If  the  temperature  of  the needle  does  not reach  the  product  temperature  at  the end of  blast 

chilling/freezing within the maximum duration of blast chilling/freezing, the cycle fails and re-

mains active. 

 

Information about the active cycle 

PHASE 

INFORMATION DISPLAYED 

blast  chilling/freezing  ac-

tive 

needle temperature 

 

end blast chilling/freezing 

End (press a key) 

conservation active 

cabinet temperature 

 

Viewing other information about the active cycle 

Check that the keypad is not locked. 

1. 

 

Touch  the  DOWN  key  to  view  the  remaining  time  of  the  maxi-

mum duration of the blast chilling/freezing cycle (or the elapsed 

time  from  the  end  of  the  maximum  duration  of  the  blast 

chilling/freezing cycle if it has failed). 

2. 

 

Touch the DOWN key again to view the type of active cycle. 

 

LAB. 

LED 

DESCRIPTION 

 

PoS 

 

temperature controlled blast chilling and conservation 

Reviews: