Route the RS485 MAX protocol (smart charging) network cable from the power supply cabinet to the
controller in the charging station. The network cable is connected to the grey connector on the right
side of the controller in the Hub station.
• Use a RS485 connector, 2-pin, white, for the RS485 connection.
• Use SFTP Category 6 network cable suited to the RS485 protocol for the data connection.
• Use the blue/blue-white twisted pair of wires for the RS485 connections.
• For correct operation of a smart grid, a Hub-Satellite configuration must be connected from a
single power cabinet. If a group of charging stations is powered from a different power cabinet
then that group stations must be a separate Hub-Satellite configuration.
Connect the smart charging network cables in accordance with the diagram.
4.2.5. Install cover
See the corresponding illustrations in manual B.
1. For a Charging station with a RCBO
: Switch the RCBO to the I (on) position.
2.
Install the cover:
a. Apply silicone grease to the seal around the charging station frame to ensure protection
against water and dirt.
b. In the station, make sure that the wiring around the charging socket is clear of the charging
socket locking mechanism.
EN
4. Installation instructions
28
Summary of Contents for BusinessLine
Page 1: ...EVBox BusinessLine Installation and commissioning manual Part A 1...
Page 2: ......
Page 3: ...EVBox BusinessLine Installation and commissioning manual Part A...
Page 4: ......
Page 43: ...The Netherlands www evbox com support 6 Appendix EN 39...
Page 44: ...EN 6 Appendix 40...
Page 45: ......