        Evakool Indel B 31 40 50 AC/DC Compressor Portable 

Fridge / Freezer – Operation Manual 

7 | 

P a g e

 

 

7.

 

Technical Data (DC/AC ) 

CLIMATIC CATEGORY                          

PROTECTIVE CLASSIFICATION

OF ELECTRIC SHOCK RESISTANCE          

RATED VOLTAGE AC

RATED FREQUENCY AC

RATED VOLTAGE DC

TOTAL INPUT POWER

RATED CURRENT FOR AC

RATED CURRENT FOR DC

ENERGY CONSUMPTION

(used as refrigerator)

ENERGY CONSUMPTION

(used as freezer      )

FREEZING CAPACITY

REFRIGERANT

NET WEIGHT

BLOW AGENT

T , ST , N , SN

100

V - 240V ~

50/60 

HZ

12

V - 24V  

AC FUSE

3

A

DC FUSE

15

A

45

W

0.20

A - 0.40A

1.9

A  - 3.8A

0.13

kW¡ ¤

h / 24h

0.40

kW¡ ¤

h / 24h

1.5

kg / 24h

R134a (40g)

16.0 

kg

C - P

MODEL    YCD31                      

CLIMATIC CATEGORY                          

PROTECTIVE CLASSIFICATION

OF ELECTRIC SHOCK RESISTANCE          

RATED VOLTAGE AC

RATED FREQUENCY AC

RATED VOLTAGE DC

TOTAL INPUT POWER

RATED CURRENT FOR AC

RATED CURRENT FOR DC

ENERGY CONSUMPTION

(used as refrigerator)

ENERGY CONSUMPTION

(used as freezer      )

FREEZING CAPACITY

REFRIGERANT

NET WEIGHT

BLOW AGENT

T , ST , N , SN

100

V - 240V ~

50/60 

HZ

12

V - 24V  

AC FUSE

3

A

DC FUSE

15

A

45

W

0.20

A - 0.40A

1.9

A  - 3.8A

0.13

kW¡ ¤

h / 24h

0.40

kW¡ ¤

h / 24h

1.5

kg / 24h

R134a (40g)

17.0 

kg

C - P

MODEL    YCD40                      

 

Summary of Contents for Indel B 31

Page 1: ...ol 16 Enterprise St CALOUNDRA QLD 4551 Tel 07 5492 7777 Fax 07 5492 7733 Please read this manual carefully before using your unit Section Page Key Product Features 2 Safety Instructions 2 Notes on using the product 2 Operation 3 4 Cleaning and Maintenance 4 5 Troubleshooting 5 6 Safety Certificate 6 Technical Data 7 8 ...

Page 2: ... 15 Amp DC 24 Volt is 7 5 Amp and AC is 4 Amp Make sure the voltage is within the correct range for socket and cable being used The technical data label on the side of the unit shows the voltage ranges Do not place any electrical devices inside the refrigerator as they may be damaged 2 Notes on using the product o Your unit requires good ventilation especially around the back of the refrigerator a...

Page 3: ...otection Selecting the Low Med High positions of the switch next to the DC power socket you can choose different levels for battery protection In the below table you can find the voltages when the compressor stops running cut out and when the compressor restarts working cut in o Cable Length Specification The DC cables must have a suitable cross section for their length measured from the battery t...

Page 4: ...e the MAX indicator red LED light will be on o The economy mode runs the compressor at a lower speed to save power the maximum mode runs the compressor at a higher speed increasing power usage Maximum mode is useful if the ambient temperature is over 30 Cº or fast cooling is required o Plug in the DC or AC power Press the button ON OFF to turn the unit on The LED display on the control panel will ...

Page 5: ...ents or hard objects during cleaning as these can damage the unit 5 Troubleshooting The unit is not turning on o Check whether the unit has been turned on o Check the power supply try a different power source i e different vehicle or power socket o Check whether the plug and the socket have a good connection o Check whether the fuse has been burned out or blown Low refrigeration performance o Too ...

Page 6: ... running water from inside the unit o This is normal due to the flow of refrigerant in the unit Unusual noise when refrigerator is working o The refrigerator is not placed on a level surface If none of the above solves your issue please contact Evakool or your local Evakool service centre 6 Security Certificate SAA ...

Page 7: ... T ST N SN Ⅰ 100V 240V 50 60 HZ 12V 24V AC FUSE 3A DC FUSE 15A 45W 0 20A 0 40A 1 9A 3 8A 0 13kW h 24h 0 40kW h 24h 1 5kg 24h R134a 40g 16 0 kg C P MODEL YCD31 CLIMATIC CATEGORY PROTECTIVE CLASSIFICATION OF ELECTRIC SHOCK RESISTANCE RATED VOLTAGE AC RATED FREQUENCY AC RATED VOLTAGE DC TOTAL INPUT POWER RATED CURRENT FOR AC RATED CURRENT FOR DC ENERGY CONSUMPTION used as refrigerator ENERGY CONSUMPT...

Page 8: ...C RATED FREQUENCY AC RATED VOLTAGE DC TOTAL INPUT POWER RATED CURRENT FOR AC RATED CURRENT FOR DC ENERGY CONSUMPTION used as refrigerator ENERGY CONSUMPTION used as freezer FREEZING CAPACITY REFRIGERANT NET WEIGHT BLOW AGENT T ST N SN Ⅰ 100V 240V 50 60 HZ 12V 24V AC FUSE 3A DC FUSE 15A 45W 0 20A 0 40A 1 9A 3 8A 0 13kW h 24h 0 40kW h 24h 1 5kg 24h R134a 40g 18 5 kg C P MODEL YCD50 ...

Reviews: