Introduction:
The ZW96 is a Z-Wave enabled device and is fully compatible with any Z-Wave Plus enabled network.
around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
ZW96 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.
Key Features:
---Remote ON/OFF control via the Z-Wave controller
---Manual ON/OFF control with the front panel push button
---Support Association Group and Auto Report switch status
---Over temperature protection
---Support firmware upgrades via Over-the-air (need Gateways support)
Product Overview:
A AC plug
B Always-On outlet
C Z-Wave controlled outlet
D ON/OFF/PROG Push button
E Status LED
Z-Wave Remote Control
ADD or Remove the ZW96 from the existing Z-Wave home control network with your primary controller.
---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
Include ZW96 to/from a Z-Wave Gateway with supporting Security.The ZW96 can support the Primary Controller that implemented the security S2.
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by
Z-WaveTM Controller means “Remove” or “Exclusion”.
Z-Wave protocol Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION_V8,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION_V8,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Z-Wave Configuration Parameters
1
:
Status LED Configuration
Paramter No: 1(0x01) Size:1 Byte Value: 00(default) outlet on,led on.
Value: 01 outlet on,led off.
Value: 02 led off, led no work.
2
:
Count Down Configuration
(
The countdown time, the socket closed
)
Paramter No: 2(0x02) Size:2 Byte Value: 00 00(default) no timer.
up for 10 hours
)
Support for Association Groups
Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal
---When prompted by your primary controller, click the PROG button five times in one second.
You may use the below configuration parameters to change settings of the corresponding functionality.
D
E
A
B
C