5.4  Problem 

The vacuum pump runs too hot. 

 

  5.4.1  Possible cause 

    Ambient temperature is too high. 

    Remedy 

: Check the ambient temperature and take care of extra cooling. 

 

  5.4.2  Possible cause 

    Insufficient cooling. 

    Remedy 

: Remove dust and dirt from the pump. 

 
 

5.4.3  Possible Cause 

    Filters clogged. 
   

Remedy

 : replace filter cartridges. 

 

 

6.0 TECHNICAL DATA 

 

Technical Data 

EVDR-V010 

EVDR-V016 

Nominal displacement 

50 Hz 

10 

16 

60 Hz 

12 

19 

Ultimate vacuum level 

mbar(abs.) 

150 

150 

Motor power at 50/60Hz 

kW 

0,37 / 0,45 

0,55 / 0,66 

Nominal speed at 50/60Hz 

rpm 

1420 / 1700 

1420 / 1700 

Noise level with exhaust silencer @50Hz 

dB(A) 

60 +/-3 

61 +/-3 

Cooling medium 

 

air 

air 

Weight approx.. 

kg 

15 

22 

Admissible ambient temperature 

°C 

0 to 40 

0 to 40 

Connection  (inlet) 

G

(BSP)

 

1/2” 

1/2” 

Dimensions LxWxH 

mm 

426x202x192 

454x225x208 

 
 

Technical Data 

EVDR-V025 

EVDR-V040 

Nominal displacement 

50 Hz 

25 

40 

60 Hz 

30 

48 

Ultimate vacuum level 

mbar(abs.) 

150 

150 

Motor power at 50/60Hz 

kW 

0,75 / 0,9 

1,25 / 1,5 

Nominal speed at 50/60Hz 

rpm 

1420 / 1700 

1420 / 1700 

Noise level with exhaust silencer @50Hz 

dB(A) 

62 +/-3 

67 +/-3 

Cooling medium 

 

air 

air 

Weight approx.. 

kg 

28 

39 

Admissible ambient temperature 

°C 

0 to 40 

0 to 40 

Connection  (inlet) 

G

(BSP)

 

3/4” 

3/4” 

Dimensions LxWxH 

mm 

502x252x292 

570x270x292 

 

Summary of Contents for EVDR Series

Page 1: ...Eurovacuum Installations and Operating manual EVDR Series Vacuum pumps Models EVDR V010 till V040 Dry Rotary Vane Vacuum Pump...

Page 2: ...cription 1 2 Unpacking and Storage 1 3 Location 1 4 Power Requirements 1 5 Vacuum Connections 2 0 SAFETY 2 1 General Notices 2 2 Warning Label and explanation 2 3 Risks and warnings 3 0 OPERATION 3 1...

Page 3: ...ed with plastic caps to prevent dirt and other foreign substances from entering the pump Leave the cap in place until you are ready to pipe the pump to your equipment The pump should be stored in a dr...

Page 4: ...in parallel on a common main line should have a manual or automatic operated shut off valve or positive action check valve installed in the suction line adjacent to the pump suction flange The built i...

Page 5: ...ted 2 2 2 Read operating instruction manual Read and understand operator s manual before using this machine 2 2 3 Vane inspection Inspect the size of the vanes after 3 000 hours of running 2 2 4 Locat...

Page 6: ...wear ear protectors If noise below the designed dBA is required an external sound enclosure can be added to the system provided adequate ventilation is provided The ambient and suction air temperatur...

Page 7: ...motor Remedy Call service agent for service or exchange program 5 2 Problem Pump does not reach its usual vacuum level 5 2 1 Possible Cause Filters are clogged with debris Remedy Clean the filters or...

Page 8: ...nal speed at 50 60Hz rpm 1420 1700 1420 1700 Noise level with exhaust silencer 50Hz dB A 60 3 61 3 Cooling medium air air Weight approx kg 15 22 Admissible ambient temperature C 0 to 40 0 to 40 Connec...

Page 9: ...Eurovacuum Head office Tel 31 0 854890993 Einsteinstraat 58 info eurovacuum eu 2811EP Reeuwijk http www eurovacuum eu The Netherlands...

Reviews: