  4.3  Maintenance Chart 

   

Weekly: 

Check inline inlet filter element / Mesh. More often if high particulates in inlet stream. 

Monthly: 

Clean the pump from dust and dirt. When inlet filter is installed: check the filter cartridge, 

replace if needed. 

    Every 3.000 operating hours: 

Check the vanes size. Replace vanes if under the size. 

   

Semi-Annually: 

Check cooling fan. More often if dirty environment. 

 

 

5.0  PROBLEM SOLVING 

 

5.1  Problem

  

 

Pump does not start.  

 

  

5.1.1  Possible Cause 

   

Wrong voltage supplied.

 

   

Remedy

 : Check the power supply and compare it with the pump motor data. 

  

 

 

5.1.2  Possible Cause

 

    Damaged electric motor. 
   

Remedy

 : Call service agent for service or exchange program. 

 
5.2  Problem

  

  Pump does not reach its usual vacuum level.  

 

 

5.2.1  Possible Cause 

    Filters are clogged with debris. 
   

Remedy

 : Clean the filters or replace them if needed . 

 

 

 

5.2.2  Possible Cause 

    Vacuum regulator is out of order. 
   

Remedy

 : Clean and check the regulator or replace it with new one. 

 
 

5.2.3  Possible Cause 

    Vanes are stuck. 
   

Remedy

 : Free the vanes or replace them. 

 
 

5.2.4  Possible Cause 

    Vanes are worn out. 

   

Remedy

 : Replace the vanes and clean the pump inside. 

 

5.3  Problem 

Vacuum pump runs very noisily. 

 

  5.3.1  Possible cause 

    The pump runs in the wrong direction. 

    Remedy 

: Check and change the rotation direction if needed. 

 

  5.3.2  Possible cause 

    Defective bearings. 

    Remedy 

: Repair the pump or call service agent for service or exchange program. 

 

 

Summary of Contents for EVDR Series

Page 1: ...Eurovacuum Installations and Operating manual EVDR Series Vacuum pumps Models EVDR V010 till V040 Dry Rotary Vane Vacuum Pump...

Page 2: ...cription 1 2 Unpacking and Storage 1 3 Location 1 4 Power Requirements 1 5 Vacuum Connections 2 0 SAFETY 2 1 General Notices 2 2 Warning Label and explanation 2 3 Risks and warnings 3 0 OPERATION 3 1...

Page 3: ...ed with plastic caps to prevent dirt and other foreign substances from entering the pump Leave the cap in place until you are ready to pipe the pump to your equipment The pump should be stored in a dr...

Page 4: ...in parallel on a common main line should have a manual or automatic operated shut off valve or positive action check valve installed in the suction line adjacent to the pump suction flange The built i...

Page 5: ...ted 2 2 2 Read operating instruction manual Read and understand operator s manual before using this machine 2 2 3 Vane inspection Inspect the size of the vanes after 3 000 hours of running 2 2 4 Locat...

Page 6: ...wear ear protectors If noise below the designed dBA is required an external sound enclosure can be added to the system provided adequate ventilation is provided The ambient and suction air temperatur...

Page 7: ...motor Remedy Call service agent for service or exchange program 5 2 Problem Pump does not reach its usual vacuum level 5 2 1 Possible Cause Filters are clogged with debris Remedy Clean the filters or...

Page 8: ...nal speed at 50 60Hz rpm 1420 1700 1420 1700 Noise level with exhaust silencer 50Hz dB A 60 3 61 3 Cooling medium air air Weight approx kg 15 22 Admissible ambient temperature C 0 to 40 0 to 40 Connec...

Page 9: ...Eurovacuum Head office Tel 31 0 854890993 Einsteinstraat 58 info eurovacuum eu 2811EP Reeuwijk http www eurovacuum eu The Netherlands...

Reviews: