– 13–
5 Local Operation
The LCD displays the setpoint temperature if Spirt ZigBee is in thermostat mode or displays pi heating demand
if it is in actuator mode.
5.1 Setting the target temperature
The target temperature is changed if Plus and Minus button is used.
The changing will cause different setpoint temperature.
Occupied and Unoccupied heating setpoint can only be changed by rf.
The target temperature takes effect 10 seconds after the last entry is made.
The entry range of the target temperature is 5° - 30°C.
Should the temperature be increased above it respectively, the Spirit ZigBee switches to Boost mode.
5.2 Activating the child safety lock
The child safety lock can activated / deactivated by pressing the Plus and Minus button for 3 seconds.
5.3 Changing the operating mode
Boost mode
Activate / deactivate boost mode by pressing Boost button.
As an alternative, you can press the Plus button until ON appears in the display.
Comfort mode
If the device is not in comfort mode, it can be switched to the comfort mode using the Plus or Minus button.