Scope of supply
1x Comet Z-wave
1x Operating instructions (part of the product)
3x Adapters (Danfoss RA, Danfoss RAV, Danfoss RAVL)
Intended use
With Comet Z-wave, you have acquired a programmable radiator thermo-
stat, which can be used to regulate temperature in closed rooms and thus
can contribute to a reduction in heat energy. Please use the regulator for
this purpose only.
Safety instructions
Never recharge, short-circuit or disassemble the batteries - danger
of explosion! Remove expired batteries from the device immediately.
Shield batteries from strong heat - increased risk of leakage!
Do not use new and old batteries together. Clean batteries and device
contact before installation if necessary. Keep batteries away from
children. Avoid contact with skin, eyes and mucous membranes.
Rinse areas affected by battery acid with clean water immediately
and seek medical advice.
Description
Comet Z-wave is a Z-Wave radio standard compatible
energy-saving radiator thermostat.
Use
The installation of the Comet Z-waves can easily be installed on all known
valve bottom sections; without dirt or water spots because the heating
circuit is not interrupted.
1. Fully unscrew the old thermostat, loosen the fi tting
and remove from the valve.
2. 2. Remove the battery cover, by pressing it upwards on the marked spot
(1) and take it off its hinges (2).
(1)
(2)
Install the batteries as shown. Do not use rechargeable batteries!
Ensure correct polarity! PREP appears on the display. The motor will
start completely in order to facilitate installation. As soon as the regulator
is installation-ready, INST appears on the display. The fl ashing radio
symbol signals that the device is ready to be enrolled. Start the enrolment
procedure (Inclusion) on your Gateway/Controller in order to include the
device in the network.
3. Screw the union nut (ring on product) on the valve. If the union nut does
not
fi t on you valve, you probably need an adapter.
4. Press the button in the battery compartment. The energy-saving thermo
stat shows ADAP in the display and carries out an initialisation run.
After initialisation, the energy-saving thermostat shows the main screen.
INFO When an error occurs, an error code is shown.
Look in the „Help“ table.
No adapter is required for the following valves:
Heimeier, Junkers Gyr, MNG, Honeywell Braukmann, since
these have thread dimensions of M30 x 1.5 mm. Adapters for Danfoss
RAV (pin must be put on the valve tappet) Danfoss RA and Danfoss
RAVL are enclosed.
An adapter is required for the following valves:
Herz M28 x 1.5 mm, Comap M28 x 1.5 mm, Vaillant 30.5 mm, Oventrop
M30 x 1.0 mm, Meges M38 x 1.5 mm, Ondal M38 x 1.5 mm, Giacomini
22.6 mm, Rossweiner M33 x 2.0 mm, Markaryd M28 x 1.0 mm, Ista M32
x 1.0 mm, Vama M28 x 1.0 mm, Pettinaroli M28 x 1.5 mm, T+A M28 x 1.5
mm or Gampper 1,2,6. These can be found at www.eurotronic.org
Please fully remove the plastic connectors before you use one of the
enclosed adapters! Please fully remove the connecting rods marked
in grey before installing the adapter!
Addition/removal to/from the network
In order to enrol and delete the device manually, start the enrolment/
deletion process of your central unit/gateway. Press and hold the
button in the battery compartment of the Comet Z-wave for 5
seconds. The device moves into installation position in order
to enable (de)installation.
Operation and display elements on the display
1. Battery empty
2. Comfort temperature active
3. Economy temperature active
4. Window-/frost protection function active
5. Wireless active
6. AUTO or MANU mode active
7. Adjusting wheel + and -
8. Button in battery compartment
Basic modes of operation
AUTO mode
The Comet Z-wave regulates temperature as per factory settings or
wireless set-up
Factory settings
Comfort temperature (Factory settings 22°C)
Economy temperature (Factory settings 18°C)
MANU mode
Comet Z-wave switches to MANU mode when you change the
temperature by hand on the adjusting wheel. The setting overwrites
the wireless set-up for two hours. After this, the setting changes
automatically to the previously-programmed setting. If you wish to
change the settings prior to this, you may do this via wireless.
Standby
The screen switches off 30 seconds after the last entry on the device
to save electricity. The display can be switched on again by turning the
adjusting wheel in any direction.
Frost protection, open window recognition and hard water protection
functions are automatically active.
Frost protection function
If the temperature falls below 6°C, the energy-saving thermostat
opens the valve until the temperature rises above 8°C again.
This stops the radiator from freezing.
Hard water function
To avoid calcifi cation of the radiator valves, the energy-saving
thermostat carries out a hard water protection cycle once a week.
Open window function
If the temperature falls sharply, open window recognition is activated
and the open window active symbol is shown. In this instance, the
valve is closed for 15 minutes.
Uninstallation
In order to uninstall the energy-saving thermostat, press and hold the
button down for 3 seconds. The device moves into the installation po-
sition. When the installation position has been reached (display shows
INST), youmay take out the batteries and unscrew the energy-saving
thermostat from the valve.
Cleaning
Use only a dry to lightly-damp cloth to clean the Comet Z-wave.
Avoid using chemical solvents,. They may damage the device.
Advice on environmental protection:
From the date of implementation of European guidelines
2002/96/EC and 2006/66/EC, into national law, the following
applies: Electric and electronic devices and batteries may
not be disposed of in household waste. The consumer
is obliged to return electric and electronic devices and
batteries to the public collection points established for
them or to the point of sale. The particulars of this are regulated
by the applicable state laws. The symbol on the product, operation
instructions or packaging points to these provisions. You make
an important contribution to the protection of the environment by
reusing or recycling old equipment/batteries or making use of them
in other ways.
Declaration of conformity
Eurotronic Technology GmbH hereby declares that this
device is compliant with the essential requirements and
other relevant provisions of 1995/5/EC. The declaration of
conformity according to the R&T TE guideline 99/5/EC can be found at
www.eurotronic.org.
Guarantee
The three-year warranty begins on the day of purchase. Please keep
the receipt as evidence of purchase in the future. During the guaran-
tee period, defective radiator thermostats may be sent to the service
address below. Please ensure suffi cient postage is paid. A new or
repaired device will then be sent to you free of charge. Following
expiry of the guarantee, you may still send the defective device to
the address below for repairs. Please ensure suffi cient postage is
paid. Repairs carried out after the guarantee period are subject to a
charge. Your legal rights are not affected by this guarantee. There
is no new warranty period starting when repairing or replacing the
device. Please note that we only grant warranty on the function of
the device. We will not grant warranty for the interaction between
the thermostat and the bottom part of the valve. The technical data
is only valid for the use of the following valves: Heimeier, Junkers
Gyr, MNG, Honeywell, Braukmann (measure of thread M30
x 1,5), Oventrop (M30 x 1,5) Danfoss RA, RAV and RAVL. Please see
the combinations of the devices on our website (www.eurotronic.
org/ Adapter list) EUROtronic does not issue a guarantee when using
the thermostat with valves which are not mentioned above.
Operating instructions
Comet Z-wave
An intelligent home in two simple steps:
www.eurotronic.org
Installation
Install the batteries. PREP appears on the display. The motor will start
completely in order to facilitate installation. INST appears on the display
as soon as the Comet Z-wave is installation-ready. The fl ashing radio
symbol signals that the device is ready to be enrolled.
Restoring factory settings
To restore factory settings, proceed as follows:
1) Start the deletion process through the central unit or Gateway
2) Press and old the button in the battery compartment for 5 seconds.
Button in battery compartment
Comet Z-wave