Eurotops 94086 User Manual Download Page 5

8.

 

Configuration 

1.  IR Sensor 
2.  LCD Display 
3.  MODE Button 
4.  Down Button 
5.  Up Button 
6.  Set Button 
7.  ON/ Scan Button 
8.  Battery Cover 

 
 
 

9.

 

LCD Indicator

 

 

1. 

Surface Mode 

2. 

Body Mode 

3. 

Ambient Temperature Mode  

4. 

Digital Readout 

5. 

Smile or Cry Indicator  

6. 

Battery Indicator  

7. 

Buzzer on/ off Indicator 

8. 

Memories 

9. 

°C 

10. 

Memory number 

11. 

°F 

 

10.

 

Operation 

10-1. Install battery 
Push the battery cover by the arrow, open the battery cover, insert two pieces AAA 
size batteries according to the “+” and “-", and close the battery cover.  

Note: Make sure the right positive and negative charges of the battery. 

 

 

 

10-1-1. For the first use or when inserting new batteries, wait 10 minutes for warming up the 
device. 
10-1-2. If the device is not used for a long time once you turn it on again, the device will test the 
room temperature firstly and will delay turning on for more one two seconds.

Summary of Contents for 94086

Page 1: ...SC889 FR 8806 NON CONTACT INFRARED BODY THERMOMETER User manual PLEASE READ THE MANUAL BEFORE YOUR FIRST USE KEEP THIS MANUAL SAFE FOR FUTURE REFERENCE English...

Page 2: ...the thermometer is properly set 2 General Descriptions The non contact IR thermometer is specially designed to test the temperature of the forehead from babies to adults and it has a variety of functi...

Page 3: ...thermometer is not intended as substitute for consultation with your physician please turn to the doctor once the measuring result seems abnormal 5 Features Multiple functions Not only can measure bo...

Page 4: ...0 3 C 93 2 94 8 F 0 5 F 35 0 42 0 C 0 2 C 95 0 107 6 F 0 4 F 42 1 42 9 C 0 3 C 107 8 109 2 F 0 5 F 43 0 100C C 2 0 C 2 C 109 4 212 F 13 6 F 2 F Measuring time 1 seconds Measuring distance 1 3CM Resolu...

Page 5: ...10 Operation 10 1 Install battery Push the battery cover by the arrow open the battery cover insert two pieces AAA size batteries according to the and and close the battery cover Note Make sure the ri...

Page 6: ...mperature in front of fans air outlets of the air condition etc where the airflow is floating 10 2 2 To obtain stable and reliable data you should keep the device for 15 20 minutes to balance its own...

Page 7: ...ce power off the setting is finished 10 5 4 Buzzer On Off setting F4 When the device is ON short press the SET button four times the LCD will display F4 press UP and DOWN to On or Off the buzzer and p...

Page 8: ...our forehead ear oral auxiliary etc to check our health conditions Different temperature will be for different body parts please kindly check the values as following Measurement Normal Temperature C...

Page 9: ...pes Always pay attention to battery polarity WARNING You should not dispose of this device with your household waste A selective collection system for this type of product is implemented by your local...

Reviews: