Eurotherm Invensys PG6 Manual Download Page 8

o

ptional

 f

eatureS

 

and

 a

cceSSorieS

COMPACTFLASH SOCKET

CompactFlash socket is a Type II socket that can accept either Type I or II 

cards. Use cards with a minimum of 4 Mbytes and a maximum of 2 Gbytes with 

the  PG6’s  CompactFlash  socket.  Cards  are  available  at  most  computer  and 

office supply retailers.

CompactFlash can be used for configuration transfers, larger configurations, 

data logging, and trending. 

Information stored on a CompactFlash card by a PG6 can be read by a card 

reader  attached  to  a  PC.  This  information  is  stored  in  IBM (Windows

®

)  PC 

compatible FAT16 file format.

CompactFlash-

Insert Face Up

CompactFlas

h

(Top Side

)

OPTIONAL COMMUNICATION CARD

Invensys/Eurotherm  offers  optional  communication  cards  for  fieldbus 

communications.    These  communication  cards  will  allow  your  PG6  to 

communicate with many of the popular fieldbus protocols.

Invensys/Eurotherm  is  also  offering  a  communications  card  for  additional 

RS232 and RS422/485 communications. Visit Invensys/Eurotherm’s website for 

information and availability of these cards.

Note: Do not remove or insert 

the CompactFlash card while 

power is applied. Refer to 

“Front Panel LEDs.”

NOTE

For reliable operation of this and other Invensys/Eurotherm products, one 

of the following brands of CompactFlash card must be used...

SimpleTech 

SMART

®

 Modular

SanDisk

® 

Silicon Systems

Not all of the above manufacturers offer CompactFlash cards recognized 

to UL standards, which may be required for your application.

Invensys Eurotherm USA Headquarters
44621 Guilford Drive Suite 100
Ashburn, VA 20147

Telephone: 703 724-7300
Fax 703 724-7301
Email: [email protected]

Summary of Contents for Invensys PG6

Page 1: ...N01 2 GB CompactFlash Card 1 PGX N02 PGX RS 232 485 Optional Communication Card PGX RS CANopen Optional Communication Card PGX CAN DeviceNet Optional Communication Card PGX DNET Profibus DP Optional Communication Card PGX PBUS GSM GPRS Modem Option Card 2 PGX GSM GUIcon 1 0 3 CBL RS 232 Programming Cable CBL01500 USB Cable CBL01900 Communications Cables 4 CBLxxxxx Replacement Battery 5 PGX BNL2000...

Page 2: ...ing from 0 to 50 C Vibration according to IEC 68 2 6 Operational 5 to 8 Hz 0 8 p p 8 to 500 Hz in X Y Z direction duration 1 hour 3 g Shock according to IEC 68 2 27 Operational 40 g 9 msec in 3 directions Altitude Up to 2000 meters 9 CERTIFICATIONS AND COMPLIANCES SAFETY UL Listed File E340808 UL61010 1 ANSI ISA 12 12 01 2007 CAN CSA 22 2 No 61010 1 CSA22 2 No 213 M1987 and File E57965 UL61010 1 C...

Page 3: ...eet 1 8 m of cable between the supply and the operator interface Ideally the shortest length possible should be used The wire used to connect the operator interface s power supply should be at least 22 gage wire If a longer cable run is used a heavier gage wire should be used The routing of the cable should be kept away from large contactors inverters and other devices which may generate significa...

Page 4: ...he target PG6 and powered Refer to the GUIcon literature for more information on the proper names and locations of the files USB DATA TRANSFERS FROM THE COMPACTFLASH CARD In order to transfer data from the CompactFlash card via the USB port a driver must be installed on your computer This driver is automatically installed with GUIcon Connect the PG6 to your PC with a USB cable and follow Mounting ...

Page 5: ...3 COM 5 GND N C 6 DSR 1 CTS 7 RTS 6 RTS 8 CTS N C 9 RI DH485 COMMUNICATIONS The PG6 s RS422 485 COMMS port can also be used for Allen Bradley DH485 communications WARNING DO NOT use a standard DH485 cable to connect this port to Allen Bradley equipment A cable and wiring diagram are available from Invensys Eurotherm PG6 to AB SLC 500 CBLAB003 24V TxA 3 8 COMM TxB 4 7 SHIELD 4 COMM 6 TxEN 5 TxEN 5 ...

Page 6: ... the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the GUIcon User Manual TOUCHSCREEN This operator interface utilizes a resistive analog touchscreen for user input The unit will only produce an audible tone beep when a touch on an active touchscreen cell is sensed The touchscreen is ...

Page 7: ...ease note that the old battery must be disposed of in a manner that complies with your local waste regulations Also the battery must not be disposed of in fire or in a manner whereby it may be damaged and its contents come into contact with human skin The battery used by the PG6 is a lithium type CR2025 LED DRIVER BOARD BATTERY CAUTION The circuit board contains static sensitive components Before ...

Page 8: ...tion cards for fieldbus communications These communication cards will allow your PG6 to communicate with many of the popular fieldbus protocols Invensys Eurotherm is also offering a communications card for additional RS232 and RS422 485 communications Visit Invensys Eurotherm s website for information and availability of these cards Note Do not remove or insert the CompactFlash card while power is...