Eurotherm Invensys PG6 Manual Download Page 2

2

1. 

POWER REQUIREMENTS

:

Must use NEC Class 2 or Limited Power Source (LPS) rated power supply.

Power connection via removable three position terminal block.

Supply Voltage: 

+24 VDC ±20% 

Typical Power

1

8 W

Maximum Power

2

:  10 W

Notes: 

1.  Typical  power  with  +24  VDC,  RS232/485  communications,  Ethernet 

communications, CompactFlash card installed, and display at full brightness.

2. Maximum power indicates the most power that can be drawn from the 

PG6.  Refer  to  “Power  Supply  Requirements”  under  “Installing  and 

Powering the PG6.”

3. The PG6’s circuit common is not connected to the enclosure of the unit. 

See  “Connecting  to  Earth  Ground”  in  the  section  “Installing  and 

Powering the PG6.”

4.  Read  “Power  Supply  Requirements”  in  the  section  “Installing  and 

Powering the PG6” for additional power supply information.

2. 

BATTERY

: Lithium coin cell. Typical lifetime of 10 years.

3. 

LCD DISPLAY

:

*Lifetime at room temperature. Refer to “Display” in “Software/Unit Operation”

4. 

5-KEY KEYPAD

: for on-screen menus.

5. 

TOUCHSCREEN

: Resistive analog

6. 

MEMORY

:

On Board User Memory

: 8 Mbyte of non-volatile Flash memory.

Memory  Card

:  CompactFlash  Type  II  slot  for  Type  I  and  Type  II 

CompactFlash cards.

7. 

COMMUNICATIONS

:

USB  Port

: Adheres  to  USB  specification  1.1.  Device  only  using  Type  B 

connection.

Serial Ports

: Format and Baud Rates for each port are individually software 

programmable up to 115,200 baud.

PGM Port: RS232 port via RJ12.

COMMS Ports: RS422/485 port via RJ45, and RS232 port via RJ12.

DH485 TXEN: Transmit enable; open collector, V

OH

 = 15 VDC, 

V

OL

 = 0.5 V @ 25 mA max.

Note:  For  additional  information  on  the  communications  or  signal 

common and connections to earth ground please see the “Connecting to 

Earth Ground” in the section “Installing and Powering the PG6.”

Ethernet Port

: 10 BASE-T / 100 BASE-TX

RJ45 jack is wired as a NIC (Network Interface Card).

Isolation from Ethernet network to PG6 operator interface: 1500 Vrms

8. 

ENVIRONMENTAL CONDITIONS

:

Operating Temperature Range

: 0 to 50 °C

Storage Temperature Range

: -20 to 70 °C

Operating and Storage Humidity

: 80% maximum relative humidity (non-

condensing) from 0 to 50 °C.

Vibration according to IEC 68-2-6

: Operational 5 to 8 Hz, 0.8" (p-p), 8 to 

500 Hz, in X, Y, Z direction, duration: 1 hour, 3 g.

Shock according to IEC 68-2-27

: Operational 40 g, 9 msec in 3 directions.

Altitude

: Up to 2000 meters.

9. 

CERTIFICATIONS AND COMPLIANCES

:

SAFETY

UL Listed, File #E340808, UL61010-1, ANSI/ISA 12.12.01-2007, CAN/CSA 

22.2 No. 61010.1, CSA 22.2 No. 213-M1987 and File #E57965, UL61010-1, 

CAN/CSA 22.2 No.61010-1

LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards

Type 4X Indoor Enclosure rating (Face only), UL50

IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment 

for measurement, control, and laboratory use, Part 1.

IP66 Enclosure rating (Face only), IEC 529

ELECTROMAGNETIC COMPATIBILITY

Emissions and Immunity to EN 61326: Electrical Equipment for Measurement, 

Control and Laboratory use.

Note:

1. Criterion A: Normal operation within specified limits.

10. 

CONNECTIONS

: Compression cage-clamp terminal block.

Wire Gage: 12-30 AWG copper wire

Torque: 5-7 inch-pounds (56-79 N-cm)

11. 

CONSTRUCTION

:  Steel  rear  metal  enclosure  with  NEMA  4X/IP66 

aluminum front plate for indoor use only when correctly fitted with the gasket 

provided. Installation Category II, Pollution Degree 2.

12. 

MOUNTING REQUIREMENTS

: Maximum panel thickness is 0.25" (6.3 

mm). For NEMA 4X/IP66 sealing, a steel panel with a minimum thickness of 

0.125" (3.17 mm) is recommended.

Maximum Mounting Stud Torque

: 17 inch-pounds (1.92 N-m)

13. 

WEIGHT

: 3.0 lbs (1.36 Kg)

8.83 (224.3)

7.08

(179.8)

2.30 (58.4)

7.42 (188.5)

5.67

(144)

DIMENSIONS  In inches (mm)

S

pecificationS

SIZE

5.7-inch

TYPE

TFT

COLORS

256

PIXELS

320 X 240

BRIGHTNESS

380 cd/m

2

BACKLIGHT

*

50,000 HR TYP.

Class A

EN 55011

Emissions

Emissions:

3 V/rms

Criterion A

EN 61000-4-6

RF conducted interference

2 kV L&N-E power

2 kV power

Criterion A

EN 61000-4-4

Fast transients (burst)

Criterion A

EN 61000-4-5

Surge

1 kV L-L,

10 V/m

Criterion A

EN 61000-4-3

Electromagnetic RF fields

1 kV signal

8 kV air discharge

4 kV contact discharge

Criterion A

EN 61000-4-2

Electrostatic discharge

Immunity to Industrial Locations:

WARNING - DO NOT CONNECT OR DISCONNECT CABLES 

WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE 

NON-HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP AND 

DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT 

CONNECTION.

Summary of Contents for Invensys PG6

Page 1: ...N01 2 GB CompactFlash Card 1 PGX N02 PGX RS 232 485 Optional Communication Card PGX RS CANopen Optional Communication Card PGX CAN DeviceNet Optional Communication Card PGX DNET Profibus DP Optional Communication Card PGX PBUS GSM GPRS Modem Option Card 2 PGX GSM GUIcon 1 0 3 CBL RS 232 Programming Cable CBL01500 USB Cable CBL01900 Communications Cables 4 CBLxxxxx Replacement Battery 5 PGX BNL2000...

Page 2: ...ing from 0 to 50 C Vibration according to IEC 68 2 6 Operational 5 to 8 Hz 0 8 p p 8 to 500 Hz in X Y Z direction duration 1 hour 3 g Shock according to IEC 68 2 27 Operational 40 g 9 msec in 3 directions Altitude Up to 2000 meters 9 CERTIFICATIONS AND COMPLIANCES SAFETY UL Listed File E340808 UL61010 1 ANSI ISA 12 12 01 2007 CAN CSA 22 2 No 61010 1 CSA22 2 No 213 M1987 and File E57965 UL61010 1 C...

Page 3: ...eet 1 8 m of cable between the supply and the operator interface Ideally the shortest length possible should be used The wire used to connect the operator interface s power supply should be at least 22 gage wire If a longer cable run is used a heavier gage wire should be used The routing of the cable should be kept away from large contactors inverters and other devices which may generate significa...

Page 4: ...he target PG6 and powered Refer to the GUIcon literature for more information on the proper names and locations of the files USB DATA TRANSFERS FROM THE COMPACTFLASH CARD In order to transfer data from the CompactFlash card via the USB port a driver must be installed on your computer This driver is automatically installed with GUIcon Connect the PG6 to your PC with a USB cable and follow Mounting ...

Page 5: ...3 COM 5 GND N C 6 DSR 1 CTS 7 RTS 6 RTS 8 CTS N C 9 RI DH485 COMMUNICATIONS The PG6 s RS422 485 COMMS port can also be used for Allen Bradley DH485 communications WARNING DO NOT use a standard DH485 cable to connect this port to Allen Bradley equipment A cable and wiring diagram are available from Invensys Eurotherm PG6 to AB SLC 500 CBLAB003 24V TxA 3 8 COMM TxB 4 7 SHIELD 4 COMM 6 TxEN 5 TxEN 5 ...

Page 6: ... the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the GUIcon User Manual TOUCHSCREEN This operator interface utilizes a resistive analog touchscreen for user input The unit will only produce an audible tone beep when a touch on an active touchscreen cell is sensed The touchscreen is ...

Page 7: ...ease note that the old battery must be disposed of in a manner that complies with your local waste regulations Also the battery must not be disposed of in fire or in a manner whereby it may be damaged and its contents come into contact with human skin The battery used by the PG6 is a lithium type CR2025 LED DRIVER BOARD BATTERY CAUTION The circuit board contains static sensitive components Before ...

Page 8: ...tion cards for fieldbus communications These communication cards will allow your PG6 to communicate with many of the popular fieldbus protocols Invensys Eurotherm is also offering a communications card for additional RS232 and RS422 485 communications Visit Invensys Eurotherm s website for information and availability of these cards Note Do not remove or insert the CompactFlash card while power is...

Reviews: